Experimental Evaluation of a Water Source CO2 Heat Pump Incorporating Novel Gas-Cooler Configuration

Author(s):  
Portia Murray ◽  
Stephen Harrison ◽  
Gary Johnson ◽  
Ben Stinson

Carbon dioxide’s use as an alternative refrigerant has been increasing in popularity due to its low global warming and ozone depletion potentials. In recent years, a number of companies and researchers have investigated applications of CO2 heat pumps for water heating. This study investigates the experimental testing of a CO2 heat pump water heater (HPWH) at Queen’s University. For the tests, the conventional factory gas-cooler on an Eco-cute unit and air-source evaporator was replaced with a specially designed brazed-plate gas-cooler. It rejected heat to a 273 litre hot water and the evaporator sourced heat from a warm water supply. Experiments were conducted using both forced and natural convection (i.e., thermosyphon) flow between the gas-cooler and hot water tank. Thermosyphon flow was studied to evaluate its effects on storage tank stratification and heat pump operation (i.e., coefficient of performance). Results were compared to forced circulation cases run over a range of flow rates. In the forced convection flow test, it was observed that a decrease in gas-cooler average water temperature increased the coefficient of performance (COP) non-linearly and an increase in the water-side flow rate increased the COP and the effectiveness of the gas-cooler. The thermosyphon had an average flow rate of 0.75 L/min and an average COP of 3.1. Thermosyphon flow kept the hot water tank fully stratified until fully charged. Water was delivered at an average of 70°C. It was also observed that thermosyphon flow rate depended on the state of charge (i.e., temperature distribution) in the storage tank. In order to increase the performance, a gas-cooler with a lower pressure drop should be used to increase the thermosyphon flow rate.

Author(s):  
Le Minh Nhut ◽  
Tran Quang Danh

Hot water is an important factor in domestic life and industrial development. Today, the heat pump is used to produce hot water more and more popular because it has many advantages of saving energy compared to the method of producing hot water by the hot water electric heater. The main aim of this study is to evaluate of the coefficient of performance (COP) of the small hot water heat pump using refrigeration R410A and R32. The capacity of both hot water heat pump is similar, one using new refrigerant R32 and other using refrigerant R410A. These heat pumps were designed and installed at the Ho Chi Minh City University of Technology and Education to evaluate the COP for the purpose of application the new refrigerant R32 for hot water heat pump. The compressor capacity is 1 Hp, the volume of hot water storage tank is of 100 liters and is insulated with thickness of 30 mm to reduce the heat loss to invironment, the required hot water temperature at the outlet of condenser is 50 oC, and the amount of required hot water is 75 liters per batch and is controlled by float valve. The experimental results indicate that the COP of the heat pump using the new refrigerant R32 is higher than heat pump using refrigerant R410A from 9% to 15% when the experimental conditions such as ambient temperature, initial water flow rate through the condenser and the required temperature of hot water were the same. In addition, the effect of the ambient temperature, initial water temperature and water flow rate were also evaluated.


Author(s):  
Michael J. Kazmierczak ◽  
Abhishek Gupta

Experiments were performed on a heat exchanger equipped with multiple thermoelectric (TE) modules. The TE-HX serves as the basic system component in a simple hydronic modular Peltier heat pump system designed to provide chilled or hot water for domestic use (or supplementary building climate control) of small residences [1]. The present work focuses on the detailed convection analysis inside the TE-HX component when 10 thermoelectric modules are utilized. The local heat transfer coefficient at different points along the channel are measured at steady-state, first, when a continuous heater is installed and then when replaced with 10 TE modules. The experimental heat transfer coefficients obtained are compared with available empirical correlations for “transition” (3000 < ReDh < 7000) turbulent flow inside the channel with fair-to-good results. Next, the resulting coefficient-of-performance of the TE heat pump system is measured with its value depending both on system input power and water flow rate. Testing showed that performance degradation, i.e. reduced COPs, occurred when operated at higher power levels but remains satisfactory for up to 688 Watts with higher flow rate.


Author(s):  
Michael J. Kazmierczak ◽  
Sreenidhi Krishnamoorthy ◽  
Abhishek Gupta

Experiments were performed to charge either cold or hot water thermal energy storage tanks using a heat exchanger equipped with multiple thermoelectric (TE) modules. The primary objective was to design a simple, but effective, modular Peltier heat pump system component to provide chilled or hot water for domestic use at the appliance level, and when arranged in multiple unit combinations, a system that can potentially satisfy small home cooling and heating requirements. Moreover, when the TEs are directly energized using solar PV panels, the system provides a renewable, pollution free and off-the-grid solution to supplement home energy needs. The present work focuses on the design and testing of a thermoelectric heat exchanger component that consists of two water channels machined from two aluminum plates with an array of three or five thermoelectric modules placed in between to transiently cool and/or heat the water in the thermal energy storage tank. The water passing over either the cold or hot side of the TE modules is recirculated to charge the cold or hot thermal storage tank, respectively. The temperatures in the prototype Peltier heat exchanger test component and thermal energy water storage tank were measured during both cold tank charging and hot tank charging operation. The thermal efficiencies of TE heat pump cooling/heating system are reported. The effects of TE power input, number of TE units and rate of fluid flow are studied.


2015 ◽  
Vol 26 (1) ◽  
pp. 96-105 ◽  
Author(s):  
Stephen Tangwe ◽  
Michael Simon ◽  
Edson L. Meyer ◽  
Sampson Mwampheli ◽  
Golden Makaka

In South Africa, there is an ongoing constraint on the electricity supply at the national grid to meet the demand. Eskom is implementing various measures such as the Integrated Demand Management and the promotion and encouragement of the use of energy efficient devices like an Air Source Heat pump (ASHP) water heater to replace the high electrical energy consuming conventional geysers for sanitary hot water production. The ASHP water heater market is fast gaining maturity. A critical mathematical model can lead to performance optimization of the systems that will further result in the conservation of energy and significant reduction in global warming potential. The ASHP water heater comprises of an ASHP unit and a hot water storage tank. In this study, a data acquisition system (DAS) was designed and built which monitored the energy used by the geyser and the whole building, the temperature at the evaporator, condenser, tank outlet hot water, tank inlet cold water, the ambient temperature and relative humidity in the vicinity of the ASHP evaporator. It is also worthy to mention that the DAS also included to a flow meter and two additional temperature sensors that measured the volume of water heated and inlet and outlet water temperature of the ASHP. This work focused on using the mathematical equation for the Coefficient of Performance (COP) of an ideal Carnot’s heat pump (CHP) water heater to develop basic computation in M-file of MATLAB software in order to model the system based on two reservoir temperatures: evaporator temperatures (Tevp) of 0°C to 40°C (approximated to ambient temperature, Ta) and condenser temperatures (TCon) set at 50°C, 55°C and 60°C (approximated to the hot water set temperature of 50°C, 55°C and 60°C) respectively. Finally, an analytical comparison of a CHP water heater to the practical ASHP water heater was conducted on a hot water set point temperature of 55°C. From the modelling results, it can be deduced that at 0°C Tevp, the COP was 5.96 and 2.63 for CHP and ASHP water heater respectively, at a hot water set temperature of 55°C. Above 20°C Tevp, the rate of change of COP increased exponentially for the ideal CHP system, but was constant at 0.01/°C for the practically modelled ASHP water heater.


2011 ◽  
Vol 480-481 ◽  
pp. 887-892 ◽  
Author(s):  
Han Dong Wang

As we know, there is plenty of waste hot water produced by families’ shower or Sauna and drained directly into the environment. It causes high energy consumption and heat pollution to the environment. In order to recover the heat of shower waste water to save energy, we developed a small scale shower waste water source heat pump (SWWHP) water heater and carried out experiments on it to study its heating performance. Experiments showed that this heat pump water heater system had advantages such as quick starting, compact structure, no need of hot water tank, stable operation and energy saving, etc. It could be used to supply hot water above 40°C for shower or heating, ventilation and air conditioning (HVAC). Measured data showed that during the whole year, when the temperatures of waste water and city water were 20.1~35°C, 20.1~30°C, respectively, it could supply hot water at volumetric flow rate of 2.5~9.6L/min and temperature of 40.1~51.2°C and its heating coefficient of performance (COPh) varied in the range of 3.06~4.81. It could supply enough shower hot water in the whole year in South China and the energy saving efficiency was obvious. Analysis also showed that the COPh was closely relevant to the ratio of temperature differences of waste water and hot water, i.e., ΔTw/ΔTh. The correlation equation of COPh and ΔTw/ΔTh was obtained by method of data regression and it could be used to evaluate the performance of the SWWHP water heater system with error of ±6%.


Author(s):  
Michael J. Kazmierczak ◽  
Sreenidhi Krishnamoorthy ◽  
Abhishek Gupta

Experiments were performed to charge either cold or hot water thermal energy storage tanks using a heat exchanger equipped with multiple thermoelectric (TE) modules. The primary objective was to design a simple, but effective, modular Peltier heat pump system component to provide chilled or hot water for domestic use at the appliance level, and when arranged in multiple unit combinations, a system that can potentially satisfy small home cooling and heating requirements. Moreover, when the TEs are directly energized using solar photovoltaic (PV) panels, the system provides a renewable, pollution-free, and off-the-grid solution to supplement home energy needs. The present work focuses on the design and testing of a thermoelectric heat exchanger component that consists of two water channels machined from two aluminum plates with an array of three, five, or eight thermoelectric modules placed in between to transiently cool and/or heat the water in the thermal energy storage tank. The water passing over either the cold or hot side of the TE modules is recirculated to charge the cold or hot thermal storage tank, respectively. The temperatures in the prototype Peltier heat exchanger test component and thermal energy water storage tank were measured during both cold and hot tank charging operations. The thermal efficiencies of the TE heat pump cooling/heating system are reported. The effects of the TE power input, number of TE units, rate of fluid flow, and heat sink/source temperature are studied.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1576
Author(s):  
Piotr Jadwiszczak ◽  
Jakub Jurasz ◽  
Bartosz Kaźmierczak ◽  
Elżbieta Niemierka ◽  
Wandong Zheng

Heating and cooling sectors contribute to approximately 50% of energy consumption in the European Union. Considering the fact that heating is mostly based on fossil fuels, it is then evident that its decarbonization is one of the crucial tasks for achieving climate change prevention goals. At the same time, electricity sectors across the globe are undergoing a rapid transformation in order to accommodate the growing capacities of non-dispatchable solar and wind generators. One of the proposed solutions to achieve heating sector decarbonization and non-dispatchable generators power system integration is sector coupling, where heat pumps are perceived as a perfect fit. Air source heat pumps enable a rapid improvement in local air quality by replacing conventional heating sources, but at the same time, they put additional stress on the power system. The emissions associated with heat pump operation are a combination of power system energy mix, weather conditions and heat pump technology. Taking the above into consideration, this paper presents an approach to estimate which of the mentioned factors has the highest impact on heat pump emissions. Due to low air quality during the heating season, undergoing a power system transformation (with a relatively low share of renewables) in a case study located in Poland is considered. The results of the conducted analysis revealed that for a scenario where an air-to-water (A/W) heat pump is supposed to cover space and domestic hot water load, its CO2 emissions are shaped by country-specific energy mix (55.2%), heat pump technology (coefficient of performance) (33.9%) and, to a lesser extent, by changing climate (10.9%). The outcome of this paper can be used by policy makers in designing decarbonization strategies and funding distribution.


2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.


Author(s):  
Ali A. Dehghan ◽  
Mohammad H. Hosni ◽  
S. Hoda Shiryazdi

The thermal performance of a Thermosyphon Domestic Solar Water Heater (DSWH) with a vertical storage tank is investigated experimentally. The system is installed on a roof - top of a four person family house and its thermal characteristics is evaluated by means of carefully measuring the temperature distribution of water inside the storage tank, solar collector flow rate and its inlet and outlet temperatures as well as load/consumption outlet and inlet temperatures and the corresponding water flow rate under a realistic operating conditions. The measurements are conducted every hour starting from morning until late night on a daily basis and continued for about 120 days during August until November 2004. It is seen that thermal stratification is well established inside the tank from 11 AM until 10 PM especially during August to September enabling the tank to provide the necessary amount of hot water at an acceptable temperature. However, thermal stratification is observed to start degrading from mid-night until morning when there is no hot water supply from the collector and due to the diffusion of heat from the top hot water layers to the bottom cold region and conduction through tank’s wall. The thermal behavior of the storage tank is also assessed based on both energy and exergy analysis and its first and second law efficiencies are calculated. It is observed that the storage tank under study has an average first law efficiency of 47.8% and is able to supply the required amount of hot water at a proper temperature. The average second law efficiency of the storage tank is observed to be 28.7% and, although is less than its first low efficiency, but is high enough to ensure that the quality of the hot water supply is well preserved. The proper level of second law efficiency is due to the preservation of the thermal stratification inside the storage tank, leading to supply of hot water at highest possible temperature and hence highest possible energy potential. Experiments are also done for no-load conditions when the storage tank only interacts with the collector, without hot water withdrawal from the tank. It is seen that for no-load condition, thermal stratification continuously develops from morning until around 16 PM after which no noticeable changes in the temperature distribution inside the tank is observed.