Modeling of Gas Turbine-Based Cogeneration System

Author(s):  
Farshid Zabihian ◽  
Alan S. Fung ◽  
Fabio Schuler

Gas turbine-based power plants generate a significant portion of world’s electricity. This paper presents the modeling of a gas turbine-based cogeneration cycle. One of the reasons for the relatively low efficiency of a single gas turbine cycle is the waste of high-grade energy at its exhaust stream. In order to recover this wasted energy, steam and/or hot water can be cogenerated to improve the cycle efficiency. In this work, a cogeneration power plant is introduced to use this wasted energy to produce superheated steam for industrial processes. The cogeneration system model was developed based on the data from the Whitby cogeneration power plant in ASPEN PLUS®. The model was validated against the operational data of the existing power plant. The electrical and total (both electrical and thermal) efficiencies were around 40% and 70% (LHV), respectively. It is shown that cogenerating electricity and steam not only significantly improve the general efficiency of the cycle but it can also recover the output and efficiency losses of the gas turbine as a result of high ambient temperature by generating more superheated steam. Furthermore, this work shows that the model could capture the operation of the systems with an acceptable accuracy.

2020 ◽  
Vol 6 (2) ◽  
Author(s):  
Emmanuel O. Osigwe ◽  
Arnold Gad-Briggs ◽  
Theoklis Nikolaidis ◽  
Pericles Pilidis ◽  
Suresh Sampath

Abstract As demands for clean and sustainable energy renew interests in nuclear power to meet future energy demands, generation IV nuclear reactors are seen as having the potential to provide the improvements required for nuclear power generation. However, for their benefits to be fully realized, it is important to explore the performance of the reactors when coupled to different configurations of closed-cycle gas turbine power conversion systems. The configurations provide variation in performance due to different working fluids over a range of operating pressures and temperatures. The objective of this paper is to undertake analyses at the design and off-design conditions in combination with a recuperated closed-cycle gas turbine and comparing the influence of carbon dioxide and nitrogen as the working fluid in the cycle. The analysis is demonstrated using an in-house tool, which was developed by the authors. The results show that the choice of working fluid controls the range of cycle operating pressures, temperatures, and overall performance of the power plant due to the thermodynamic and heat properties of the fluids. The performance results favored the nitrogen working fluid over CO2 due to the behavior CO2 below its critical conditions. The analyses intend to aid the development of cycles for generation IV nuclear power plants (NPPs) specifically gas-cooled fast reactors (GFRs) and very high-temperature reactors (VHTRs).


Author(s):  
T. Korakianitis ◽  
J. Grantstrom ◽  
P. Wassingbo ◽  
A. F. Massardo

The design-point performance characteristics of a wide variety of combined-cogeneration power plants, with different amounts of supplementary firing (or no supplementary firing), different amounts of steam injection (or no steam injection), different amounts of exhaust gas condensation etc, without limiting these parameters to present-day limits are investigated. A representative power plant with appropriate components for these plant enhancements is developed. A computer program is used to evaluate the performance of various power plants using standard inputs for component efficiencies; and the design-point performance of these plants is computed. The results are presented as thermal efficiency, specific power, effectiveness, and specific rate of energy in district heating. The performance of the simple-cycle gas turbine dominates the overall plant performance; the plant efficiency and power are mainly determined by turbine inlet temperature and compressor pressure ratio; increasing amounts of steam injection in the gas turbine increases the efficiency and power; increasing amounts of supplementary firing decreases the efficiency but increases the power; with sufficient amounts of supplementary firing and steam injection the exhaust-gas condensate is sufficient to make up for water lost in steam injection; and the steam-turbine power is a fraction (0.1 to 0.5) of the gas-turbine power output. Regions of “optimum” parameters for the power plant based on design-point power, hot-water demand, and efficiency are shown. A method for fuel-cost allocation between electricity and hot water is recommended.


2005 ◽  
Vol 127 (1) ◽  
pp. 65-72 ◽  
Author(s):  
T. Korakianitis ◽  
J. Grantstrom ◽  
P. Wassingbo ◽  
Aristide F. Massardo

The design-point performance characteristics of a wide variety of combined-cogeneration power plants, with different amounts of supplementary firing (or no supplementary firing), different amounts of steam injection (or no steam injection), different amounts of exhaust gas condensation, etc., without limiting these parameters to present-day limits are investigated. A representative power plant with appropriate components for these plant enhancements is developed. A computer program is used to evaluate the performance of various power plants using standard inputs for component efficiencies, and the design-point performance of these plants is computed. The results are presented as thermal efficiency, specific power, effectiveness, and specific rate of energy in district heating. The performance of the simple-cycle gas turbine dominates the overall plant performance; the plant efficiency and power are mainly determined by turbine inlet temperature and compressor pressure ratio; increasing amounts of steam injection in the gas turbine increases the efficiency and power; increasing amounts of supplementary firing decreases the efficiency but increases the power; with sufficient amounts of supplementary firing and steam injection the exhaust-gas condensate is sufficient to make up for water lost in steam injection; and the steam-turbine power is a fraction (0.1 to 0.5) of the gas-turbine power output. Regions of “optimum” parameters for the power plant based on design-point power, hot-water demand, and efficiency are shown. A method for fuel-cost allocation between electricity and hot water is recommended.


Author(s):  
James Spelling ◽  
Björn Laumert ◽  
Torsten Fransson

A dynamic simulation model of a hybrid solar gas-turbine power plant has been developed, allowing determination of its thermodynamic and economic performance. In order to examine optimum gas-turbine designs for hybrid solar power plants, multi-objective thermoeconomic analysis has been performed, with two conflicting objectives: minimum levelized electricity costs and minimum specific CO2 emissions. Optimum cycle conditions: pressure-ratio, receiver temperature, turbine inlet temperature and flow rate, have been identified for a 15 MWe gas-turbine under different degrees of solarization. At moderate solar shares, the hybrid solar gas-turbine concept was shown to provide significant water and CO2 savings with only a minor increase in the levelized electricity cost.


Atomic Energy ◽  
2005 ◽  
Vol 98 (1) ◽  
pp. 21-31 ◽  
Author(s):  
A. V. Vasyaev ◽  
V. F. Golovko ◽  
I. V. Dmitrieva ◽  
N. G. Kodochigov ◽  
N. G. Kuzavkov ◽  
...  

2015 ◽  
Vol 5 (2) ◽  
pp. 89
Author(s):  
Munzer S. Y. Ebaid ◽  
Qusai Z. Al-hamdan

<p class="1Body">Several modifications have been made to the simple gas turbine cycle in order to increase its thermal efficiency but within the thermal and mechanical stress constrain, the efficiency still ranges between 38 and 42%. The concept of using combined cycle power or CPP plant would be more attractive in hot countries than the combined heat and power or CHP plant. The current work deals with the performance of different configurations of the gas turbine engine operating as a part of the combined cycle power plant. The results showed that the maximum CPP cycle efficiency would be at a point for which the gas turbine cycle would have neither its maximum efficiency nor its maximum specific work output. It has been shown that supplementary heating or gas turbine reheating would decrease the CPP cycle efficiency; hence, it could only be justified at low gas turbine inlet temperatures. Also it has been shown that although gas turbine intercooling would enhance the performance of the gas turbine cycle, it would have only a slight effect on the CPP cycle performance.</p>


Author(s):  
Esa Utriainen ◽  
Bengt Sundén

The application of recuperators in advanced thermodynamic cycles is growing due to stronger demands of low emissions of pollutants and the necessity of improving the cycle efficiency of power plants to reduce the fuel consumption. This paper covers applications and types of heat exchangers used in gas turbine units. The trends of research and development are brought up and the future need for research and development is discussed. Material aspects are covered to some extent. Attempts to achieve compact heat exchangers for these applications are also discussed. With the increasing pressure ratio in the gas turbine cycle, large pressure differences between the hot and cold sides exist. This has to be accounted for. The applicability of CFD (Computational Fluid Dynamics) is discussed and a CFD–approach is presented for a specific recuperator. This recuperator has narrow wavy ducts with complex cross-sections and the hydraulic diameter is so small that laminar flow prevails. The thermal-hydraulic performance is of major concern.


2021 ◽  
Vol 286 ◽  
pp. 04013
Author(s):  
George Iulian Balan ◽  
Octavian Narcis Volintiru ◽  
Ionut Cristian Scurtu ◽  
Florin Ioniță ◽  
Mirela Letitia Vasile ◽  
...  

Vessels that have navigation routes in areas with ambient temperatures that can drop below + 5 [°C], with a relative humidity of over 65%, will have implemented technical solutions for monitoring and combating ice accumulations in the intake routes of gas turbine power plants. Because gas turbines are not designed and built to allow the admission of foreign objects (in this case - ice), it is necessary to avoid the accumulation of ice through anti-icing systems and not to melt ice through defrost systems. Naval anti-icing systems may have as a source of energy flow compressed air, supersaturated steam, exhaust gases, electricity or a combination of those listed. The monitoring and optimization of the operation of the anti-icing system gives the gas turbine power plant an operation as close as possible to the normal regimes stipulated in the ship's construction or retrofit specification.


Author(s):  
Obumneme Oken

Nigeria has some surface phenomena that indicate the presence of viable geothermal energy. None of these locations have been explored extensively to determine the feasibility of sustainable geothermal energy development for electricity generation or direct heating. In this context, the present study aims to provide insight into the energy potential of such development based on the enthalpy estimation of geothermal reservoirs. This particular project was conducted to determine the amount of energy that can be gotten from a geothermal reservoir for electricity generation and direct heating based on the estimated enthalpy of the geothermal fluid. The process route chosen for this project is the single-flash geothermal power plant because of the temperature (180℃) and unique property of the geothermal fluid (a mixture of hot water and steam that exists as a liquid under high pressure). The Ikogosi warm spring in Ekiti State, Nigeria was chosen as the site location for this power plant. To support food security efforts in Africa, this project proposes the cascading of a hot water stream from the flash tank to serve direct heat purposes in agriculture for food preservation, before re-injection to the reservoir. The flowrate of the geothermal fluid to the flash separator was chosen as 3125 tonnes/hr. The power output from a single well using a single flash geothermal plant was evaluated to be 11.3 MW*. This result was obtained by applying basic thermodynamic principles, including material balance, energy balance, and enthalpy calculations. This particular project is a prelude to a robust model that will accurately determine the power capacity of geothermal power plants based on the enthalpy of fluid and different plant designs.


Sign in / Sign up

Export Citation Format

Share Document