Barrel-Stave Flextensional Transducers for Sonar Applications

Author(s):  
D. F. Jones ◽  
D. J. Lewis ◽  
C. G. Reithmeier ◽  
G. A. Brownell

Abstract Barrel-stave flextensional transducers are low frequency underwater projectors that can be used as active components in long-range sonar systems or as versatile sound sources in oceanographic applications. The advantages offered by this type of flextensional transducer include low frequency, high power, small size, low weight, post-assembly frequency tuning, and low cost due to simplicity in its design and assembly. The construction of three barrel-stave projectors, investigated at the Defence Research Establishment Atlantic (DREA) in recent years, is briefly described. The performance goals for each of these projectors are shown to be consistent with the criteria that distinguish the first three classes in the Brigham-Royster classification scheme for flextensional transducers. Important in-water performance parameters, such as the resonance frequencies, transmitting voltage responses, source levels, mechanical quality factors, and electroacoustic efficiencies, are presented. In addition, these parameters are compared to those of other experimental and commercial barrel-stave flextensional designs.

2017 ◽  
Vol 6 (1) ◽  
pp. 199-207 ◽  
Author(s):  
Stephen A. Drake ◽  
John S. Selker ◽  
Chad W. Higgins

Abstract. Intrinsic permeability is an important parameter that regulates air exchange through porous media such as snow. Standard methods of measuring snow permeability are inconvenient to perform outdoors, are fraught with sampling errors, and require specialized equipment, while bringing intact samples back to the laboratory is also challenging. To address these issues, we designed, built, and tested a low-cost acoustic permeameter that allows computation of volume-averaged intrinsic permeability for a homogenous medium. In this paper, we validate acoustically derived permeability of homogenous, reticulated foam samples by comparison with results derived using a standard flow-through permeameter. Acoustic permeameter elements were designed for use in snow, but the measurement methods are not snow-specific. The electronic components – consisting of a signal generator, amplifier, speaker, microphone, and oscilloscope – are inexpensive and easily obtainable. The system is suitable for outdoor use when it is not precipitating, but the electrical components require protection from the elements in inclement weather. The permeameter can be operated with a microphone either internally mounted or buried a known depth in the medium. The calibration method depends on choice of microphone positioning. For an externally located microphone, calibration was based on a low-frequency approximation applied at 500 Hz that provided an estimate of both intrinsic permeability and tortuosity. The low-frequency approximation that we used is valid up to 2 kHz, but we chose 500 Hz because data reproducibility was maximized at this frequency. For an internally mounted microphone, calibration was based on attenuation at 50 Hz and returned only intrinsic permeability. We found that 50 Hz corresponded to a wavelength that minimized resonance frequencies in the acoustic tube and was also within the response limitations of the microphone. We used reticulated foam of known permeability (ranging from 2 × 10−7 to 3 × 10−9 m2) and estimated tortuosity of 1.05 to validate both methods. For the externally mounted microphone the mean normalized standard deviation was 6 % for permeability and 2 % for tortuosity. The mean relative error from known measurements was 17 % for permeability and 2 % for tortuosity. For the internally mounted microphone the mean normalized standard deviation for permeability was 10 % and the relative error was also 10 %. Permeability determination for an externally mounted microphone is less sensitive to environmental noise than is the internally mounted microphone and is therefore the recommended method. The approximation using the internally mounted microphone was developed as an alternative for circumstances in which placing the microphone in the medium was not feasible. Environmental noise degrades precision of both methods and is recognizable as increased scatter for replicate data points.


2016 ◽  
Author(s):  
Stephen A. Drake ◽  
John S. Selker ◽  
Chad W. Higgins

Abstract. Intrinsic permeability is an important parameter that regulates air exchange through porous media such as snow. Standard methods of measuring snow permeability are inconvenient to perform outdoors, fraught with sampling errors and require specialized equipment, while bringing intact samples back to the laboratory is also challenging. To address these issues, we designed, built, and tested a low-cost acoustic permeameter that allows computation of volume-averaged intrinsic permeability for a homogenous medium. Permeameter elements were designed for use in snow but the measurement methods are not snow-specific. The electronic components, consisting of a signal generator, amplifier, speaker, microphone and oscilloscope, are inexpensive and easily obtainable. The system is suitable for outdoor use when it is not precipitating but the electrical components require protection from the elements in inclement weather. The permeameter can be operated with a microphone either internally mounted or buried a known depth in the medium. The calibration method depends on choice of microphone positioning. For an externally located microphone, calibration was based on a low-frequency approximation applied at 500 Hz that provided an estimate of both intrinsic permeability and tortuosity. The low-frequency approximation that we used is valid up to 2 kHz but we chose 500 Hz because data reproducibility was maximized at this frequency. For an internally mounted microphone, calibration was based on attenuation at 50 Hz and returned only intrinsic permeability. We found that 50 Hz corresponded to a wavelength that minimized resonance frequencies in the acoustic tube and was also within the response limitations of the microphone. We used reticulated foam of known permeability (ranging from 2 × 10−7 m2 to 3 × 10−9 m2) and estimated tortuosity of 1.05 to validate both methods. For the externally mounted microphone the mean normalized standard deviation was 6 % for permeability and 2 % for tortuosity. The mean relative error from known measurements was 17 % for permeability and 2 % for tortuosity. For the internally mounted microphone the mean normalized standard deviation for permeability was 10 % and the relative error was also 10 %. Permeability determination for an externally mounted microphone is less sensitive to environmental noise than is the internally mounted microphone and is therefore the recommended method. The approximation using the internally mounted microphone was developed as an alternative for circumstances in which placing the microphone in the medium was not feasible. Environmental noise degrades precision of both methods and is recognizable as increased scatter for replicate data points.


Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7085
Author(s):  
Jinwook Kim ◽  
Yongrae Roh

Tonpilz is a popular transducer for underwater projector arrays for sonar systems. For low-frequency transmission, a larger axial dimension of the conventional Tonpilz transducer is required. However, a bulky and heavy Tonpilz element is not suitable due to limitations in terms of the space and payload of the array platform. To address this problem, we developed a rear-mounted Tonpilz transducer to generate a sub-fundamental resonance in addition to the common longitudinal resonance. For this purpose, we developed a new equivalent circuit model that can reflect all the effects of the key design parameters of the transducer, such as suspension thickness (stiffness), tail mass thickness, and head mass thickness. The impedance and transmitting voltage response were evaluated as performance factors at both resonance frequencies. The validity of the circuit was verified by comparing the analysis results with those from the finite element analysis of the same transducer. Based on the results, the transducer structure was designed to have comparable transmitting performance at both resonance frequencies by employing relatively high suspension stiffness, light tail mass, and heavy head mass. The novel design can permit the dual-band operation of the transducer so that the transducer can operate as a wideband projector.


Micromachines ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 203
Author(s):  
Xiaohua Huang ◽  
Cheng Zhang ◽  
Keren Dai

Using the piezoelectric effect to harvest energy from surrounding vibrations is a promising alternative solution for powering small electronic devices such as wireless sensors and portable devices. A conventional piezoelectric energy harvester (PEH) can only efficiently collect energy within a small range around the resonance frequency. To realize broadband vibration energy harvesting, the idea of multiple-degrees-of-freedom (DOF) PEH to realize multiple resonant frequencies within a certain range has been recently proposed and some preliminary research has validated its feasibility. Therefore, this paper proposed a multi-DOF wideband PEH based on the frequency interval shortening mechanism to realize five resonance frequencies close enough to each other. The PEH consists of five tip masses, two U-shaped cantilever beams and a straight beam, and tuning of the resonance frequencies is realized by specific parameter design. The electrical characteristics of the PEH are analyzed by simulation and experiment, validating that the PEH can effectively expand the operating bandwidth and collect vibration energy in the low frequency. Experimental results show that the PEH has five low-frequency resonant frequencies, which are 13, 15, 18, 21 and 24 Hz; under the action of 0.5 g acceleration, the maximum output power is 52.2, 49.4, 61.3, 39.2 and 32.1 μW, respectively. In view of the difference between the simulation and the experimental results, this paper conducted an error analysis and revealed that the material parameters and parasitic capacitance are important factors that affect the simulation results. Based on the analysis, the simulation is improved for better agreement with experiments.


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Persona Paolo ◽  
Valeri Ilaria ◽  
Zarantonello Francesco ◽  
Forin Edoardo ◽  
Sella Nicolò ◽  
...  

Abstract Background During COVID-19 pandemic, optimization of the diagnostic resources is essential. Lung Ultrasound (LUS) is a rapid, easy-to-perform, low cost tool which allows bedside investigation of patients with COVID-19 pneumonia. We aimed to investigate the typical ultrasound patterns of COVID-19 pneumonia and their evolution at different stages of the disease. Methods We performed LUS in twenty-eight consecutive COVID-19 patients at both admission to and discharge from one of the Padua University Hospital Intensive Care Units (ICU). LUS was performed using a low frequency probe on six different areas per each hemithorax. A specific pattern for each area was assigned, depending on the prevalence of A-lines (A), non-coalescent B-lines (B1), coalescent B-lines (B2), consolidations (C). A LUS score (LUSS) was calculated after assigning to each area a defined pattern. Results Out of 28 patients, 18 survived, were stabilized and then referred to other units. The prevalence of C pattern was 58.9% on admission and 61.3% at discharge. Type B2 (19.3%) and B1 (6.5%) patterns were found in 25.8% of the videos recorded on admission and 27.1% (17.3% B2; 9.8% B1) on discharge. The A pattern was prevalent in the anterosuperior regions and was present in 15.2% of videos on admission and 11.6% at discharge. The median LUSS on admission was 27.5 [21–32.25], while on discharge was 31 [17.5–32.75] and 30.5 [27–32.75] in respectively survived and non-survived patients. On admission the median LUSS was equally distributed on the right hemithorax (13; 10.75–16) and the left hemithorax (15; 10.75–17). Conclusions LUS collected in COVID-19 patients with acute respiratory failure at ICU admission and discharge appears to be characterized by predominantly lateral and posterior non-translobar C pattern and B2 pattern. The calculated LUSS remained elevated at discharge without significant difference from admission in both groups of survived and non-survived patients.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Lei Hu ◽  
Yue-Wen Fang ◽  
Feiyu Qin ◽  
Xun Cao ◽  
Xiaoxu Zhao ◽  
...  

AbstractThermoelectrics enable waste heat recovery, holding promises in relieving energy and environmental crisis. Lillianite materials have been long-term ignored due to low thermoelectric efficiency. Herein we report the discovery of superior thermoelectric performance in Pb7Bi4Se13 based lillianites, with a peak figure of merit, zT of 1.35 at 800 K and a high average zT of 0.92 (450–800 K). A unique quality factor is established to predict and evaluate thermoelectric performances. It considers both band nonparabolicity and band gaps, commonly negligible in conventional quality factors. Such appealing performance is attributed to the convergence of effectively nested conduction bands, providing a high number of valley degeneracy, and a low thermal conductivity, stemming from large lattice anharmonicity, low-frequency localized Einstein modes and the coexistence of high-density moiré fringes and nanoscale defects. This work rekindles the vision that Pb7Bi4Se13 based lillianites are promising candidates for highly efficient thermoelectric energy conversion.


2021 ◽  
Vol 263 (3) ◽  
pp. 3436-3447
Author(s):  
Dan Lin ◽  
Andrew Eng

Assumptions made on the ground types between sound sources and receivers can significantly impact the accuracy of environmental outdoor noise prediction. A guideline is provided in ISO 9613-2 and the value of ground factor ranges from 0 to 1, depending on the coverage of porous ground. For example, a ground absorption factor of 1 is suggested for grass ground covers. However, it is unclear if the suggested values are validated. The purpose of this study is to determine the sound absorption of different types of ground by measurements. Field noise measurements were made using an omnidirectional loudspeaker and two microphones on three different types of ground in a quiet neighborhood. One microphone was located 3ft from the loudspeaker to record near field sound levels in 1/3 and 1 octave bands every second. The other microphone was located a few hundred feet away to record far field sound in the same fashion as the near field microphone. The types of ground tested were concrete, grass, and grass with trees. Based on the measurement data, it was found that grass and trees absorb high frequency sound well and a ground factor of 1 may be used for 500Hz and up when using ISO 9613-2 methodology. However, at lower frequencies (125 Hz octave band and below), grassy ground reflects sound the same as concrete surfaces. Trees absorb more low frequency sound than grass, but less than ISO 9613-2 suggested.


2021 ◽  
Vol 69 (1) ◽  
pp. 1-17
Author(s):  
Frank Simon ◽  
Delphine Sebbane ◽  
surname given-names

Passive acoustic liners, used in aeronautic engine nacelles to reduce radiated fan noise, have a quarter-wavelength behavior. The simplest systems are SDOF-type (single degree of freedom), consisting of a perforated sheet backed with a honeycomb, whose absorption ability is limited to frequencies near the Helmholtz frequency. Thus, to widen the absorption frequency range, manufacturers use a 2DOF (double degree of freedom) system, with an internal layer over another honeycomb (stack of two resonators). However, one constraint is the limited thickness of the overall system, which reduces the space allotted to each honeycomb. A possible approach, based on a previous concept called LEONAR (long elastic open-neck acoustic resonator), could be to link each perforated layer to hollow tubes inserted in each honeycomb layer, in order to shift resonance frequencies to lower frequencies by extending the air column lengths. The presence of an empty chamber on both sides of the internal perforated layer also allows the tube length to be increased through tubes crossing both cavities, preserving the liner thickness. The main aim of this article is to mathematically describe the principle of a 2DOF LEONAR and to show the relevance of the mathematical model through FEM simulations and experiments performed in an impedance tube. Moreover, its behavior is analyzed through a parametric study, in order to explore its potential for an aeronautic application. A remarkable feature of 2DOF LEONAR-type materials with insertion of bottom tubes in the higher cavity is the possibility of maintaining the low frequency band provided by the original LEONAR concept, while adding a second absorption peak at a higher frequency, by the second layer and the accompanying tubes. There is a fundamental difference from classical SDOF/2DOF resonators, for which the thicknesses are obviously different.


Electronics ◽  
2018 ◽  
Vol 7 (11) ◽  
pp. 330 ◽  
Author(s):  
Yuqing Hou ◽  
Changlong Li ◽  
Sheng Tang

Because of its high resolution, low cost, small volume, low power dissipation and less conversion time consumption, the direct digital synthesizer (DDS) method has been applied more and more in the fields of frequency synthesis and signal generation. However, only a limited number of precise frequency signals can be synthesized by the traditional DDS, for the reason that its accumulator modulus is fixed, and its frequency tuning word must be integer. In this paper, a precise DDS method using compound frequency tuning word is proposed, which improves the accuracy of synthesized signals at any frequency points on the premise of guaranteeing the stability of synthesized signals. In order to verify the effectiveness of the new method, a DDS frequency synthesizer based on FPGA is designed and implemented. Taking the rubidium atomic clock PRS10 as standard frequency source, the experiments shows that the frequency stability of the synthesized signal is better than 8.0 × 10−12/s, the relative frequency error is less than 4.8 × 10−12, and that the frequency accuracy is improved by three orders of magnitude compared with the traditional DDS method.


Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3721 ◽  
Author(s):  
Usman Rashid ◽  
Imran Niazi ◽  
Nada Signal ◽  
Denise Taylor

Texas Instruments ADS1299 is an attractive choice for low cost electroencephalography (EEG) devices owing to its low power consumption and low input referred noise. To date, there have been no rigorous evaluations of its performance. In this EEG experimental study we evaluated the performance of the ADS1299 against a high quality laboratory-based system. Two self-paced lower limb motor tasks were performed by 22 healthy participants. Recorded power across delta, theta, alpha, and beta EEG bands, the power ratio across the motor tasks, pre-movement noise, and signal-to-noise ratio were obtained for evaluation. The amplitude and time of the negative peak in the movement-related cortical potentials (MRCPs) extracted from the EEG data were also obtained. Using linear mixed models, no statistically significant differences (p > 0.05) were found in any of these measures across the two systems. These findings were further supported by evaluation of cosine similarity, waveform differences, and topographic maps. There were statistically significant differences in MRCPs across the motor tasks in both systems. We conclude that the performance of the ADS1299 in combination with wet Ag/AgCl electrodes is analogous to that of a laboratory-based system in a low frequency (<40 Hz) EEG recording.


Sign in / Sign up

Export Citation Format

Share Document