scholarly journals Energy Savings and Opportunities in the Citrus Industry

Author(s):  
Nathaniel Lewis ◽  
Charles Thomas

The following opportunities have significant potential to reduce the energy needs of a citrus plant. Each opportunity is identified with specific recommendations. The recent increases in fuel cost have renewed the interest and necessity to review the energy saving opportunities. Measures that were not economical a couple of years ago may now have respectable paybacks. The opportunities are divided into the following topics: • Boiler • Feed Mill • Refrigeration • Evaporation • Rates Paper published with permission.

Fluids ◽  
2021 ◽  
Vol 6 (8) ◽  
pp. 275
Author(s):  
Ahmed J. Hamad

One essential utilization of phase change materials as energy storage materials is energy saving and temperature control in air conditioning and indirect solar air drying systems. This study presents an experimental investigation evaluating the characteristics and energy savings of multiple phase change materials subjected to internal flow in an air heating system during charging and discharging cycles. The experimental tests were conducted using a test rig consisting of two main parts, an air supply duct and a room model equipped with phase change materials (PCMs) placed in rectangular aluminum panels. Analysis of the results was based on three test cases: PCM1 (Paraffin wax) placed in the air duct was used alone in the first case; PCM2 (RT–42) placed in the room model was used alone in the second case; and in the third case, the two PCMs (PCM1 and PCM2) were used at the same time. The results revealed a significant improvement in the energy savings and room model temperature control for the air heating system incorporated with multiple PCMs compared with that of a single PCM. Complete melting during the charging cycle occurred at temperatures in the range of 57–60 °C for PCM1 and 38–43 °C for PCM2, respectively, thereby validating the reported PCMs’ melting–solidification results. Multiple PCMs maintained the room air temperature at the desired range of 35–45.2 °C in the air heating applications by minimizing the air temperature fluctuations. The augmentation in discharging time and improvement in the room model temperature using multiple PCMs were about 28.4% higher than those without the use of PCMs. The total energy saving using two PCMs was higher by about 29.5% and 46.7% compared with the use of PCM1 and PCM2, respectively. It can be concluded that multiple PCMs have revealed higher energy savings and thermal stability for the air heating system considered in the current study.


2021 ◽  
pp. 1420326X2199241
Author(s):  
Hanlin Li ◽  
Dan Wu ◽  
Yanping Yuan ◽  
Lijun Zuo

In the past 30 years, tubular daylight guide systems (TDGSs) have become one of the most popular ways to transport outdoor natural light into the inner space in building design. However, tubular daylight guide systems are not widely used because of the lack of methods to evaluate methods on the suitability of the TDGSs. This study therefore summarizes the daylight performance metrics of TDGSs and presents the estimation methods in terms of field measurements, simulation and empirical formulae. This study focuses on the daylight performance and potential energy savings of TDGSs. Moreover, this study will be helpful for building designers to build healthy, comfortable and energy-saving indoor environment.


2022 ◽  
Vol 21 (1) ◽  
pp. 1-24
Author(s):  
Sheel Sindhu Manohar ◽  
Sparsh Mittal ◽  
Hemangee K. Kapoor

In the deep sub-micron region, “spin-transfer torque RAM” (STT-RAM ) suffers from “read-disturbance error” (RDE) , whereby a read operation disturbs the stored data. Mitigation of RDE requires restore operations, which imposes latency and energy penalties. Hence, RDE presents a crucial threat to the scaling of STT-RAM. In this paper, we offer three techniques to reduce the restore overhead. First, we avoid the restore operations for those reads, where the block will get updated at a higher level cache in the near future. Second, we identify read-intensive blocks using a lightweight mechanism and then migrate these blocks to a small SRAM buffer. On a future read to these blocks, the restore operation is avoided. Third, for data blocks having zero value, a write operation is avoided, and only a flag is set. Based on this flag, both read and restore operations to this block are avoided. We combine these three techniques to design our final policy, named CORIDOR. Compared to a baseline policy, which performs restore operation after each read, CORIDOR achieves a 31.6% reduction in total energy and brings the relative CPI (cycle-per-instruction) to 0.64×. By contrast, an ideal RDE-free STT-RAM saves 42.7% energy and brings the relative CPI to 0.62×. Thus, our CORIDOR policy achieves nearly the same performance as an ideal RDE-free STT-RAM cache. Also, it reaches three-fourths of the energy-saving achieved by the ideal RDE-free cache. We also compare CORIDOR with four previous techniques and show that CORIDOR provides higher restore energy savings than these techniques.


Author(s):  
Branislav Ftorek ◽  
Milan Saga ◽  
Pavol Orsansky ◽  
Jan Vittek ◽  
Peter Butko

Purpose The main purpose of this paper is to evaluate the two energy saving position control strategies for AC drives valid for a wide range of boundary conditions including an analysis of their energy expenses. Design/methodology/approach For energy demands analysis, the optimal energy control based on mechanical and electrical losses minimization is compared with the near-optimal one based on symmetrical trapezoidal speed profile. Both control strategies respect prescribed maneuver time and define acceleration profile for preplanned rest-to-rest maneuver. Findings Presented simulations confirm lower total energy expenditures of energy optimal control if compared with near-optimal one, but the differences are only small due to the fact that two energy saving strategies are compared. Research limitations/implications Developed overall control system consisting of energy saving profile generator, pre-compensator and position control system respecting principles of field-oriented control is capable to track precomputed state variables precisely. Practical implications Energy demands of both control strategies are verified and compared to simulations and preliminary experiments. The possibilities of energy savings were confirmed for both control strategies. Originality/value Experimental verification of designed control structure is sufficiently promising and confirmed assumed energy savings.


Author(s):  
Yigit Fidansoy ◽  
Sohejl Wanjani ◽  
Sebastian Schmidt

Due to the increasing scarcity of fossil fuels and the climate change, the importance of energy efficiency is increasing. This importance is major especially in areas where the energy consumption is high. Rail transport depicts such an area. The highest proportion of energy consumed in the railway is the so called traction energy. This energy is required for the train run. In the timetable, allowances leave a margin for the driving style of train run. By the selective use of strategies that change the driving style, it is possible to exploit these allowances and reduce the traction energy consumption. The first objective of this study deals with the development of algorithms for energy-saving driving style. First, the necessary input variables of the algorithms based on the literature research and the formulas of train dynamics were determined. Then the algorithms were developed to create different energy-saving driving styles, resulting choose the best result which should be shown as a driving recommendation. The developed algorithms were used in an application example in order to calculate the potential of energy-savings. The example should represent the influence of the input variables for a comparison of different situations. At last the acceptance of the determined driving strategies in practice was investigated. By implementing the design thinking method it was identified that driver advisory systems and training programs are necessary to facilitate energy-saving driving in practice.


AGROINTEK ◽  
2017 ◽  
Vol 11 (2) ◽  
pp. 75
Author(s):  
Lukman Hidayat ◽  
Fitri Electrika Dewi Surawan ◽  
Arga Harianda Lumban Raja

Increasing demand for Crude Palm Oil (CPO) as the vegetable oil was causing the industry to cultivate palm oil increased, so that the energy required to produce CPO also increased. The purpose of this study is to identify the type, source and calculate the amount of energy needs, calculate the level of efficiency and energy savings opportunities. Stages of the research are  initial energy analysis, a detailed energy, and energy analysis in processing systems. Based on the research results, to produce each kg of CPO processing capacity of 60 ton TBS / hour with a recovery rate of 20.59% of primary energy needs of 16.200679 MJ / kg. Real boiler efficiency of 45.69%, the real efficiency of the turbine was 94, 86%. Turbine efficiency  to generate electrical energy by 1.09%, the technical efficiency of 66.80% turbines, diesel generators technical efficiency of 47.25%, the technical efficiency of electric motors by 59.37%.  The total efficiency  of  electricity  use by 4,75%, the efficiency of diesel estate of 1.379% and the efficiency of the use of steam at 93.77%. Energy can be saved by 0.0442 MJ / kg with a description of human powered energy of 0.0004316 MJ / kg, energy electrical energy by .04372 MJ / kg. While energy can be stored on the excess energy to fuel biomass boiler was 1.45 MJ / kg


2021 ◽  
Author(s):  
◽  
Georgia Alexander

<p>For decades, studies have been suggesting the idea of occupancy sensors in intermittent use spaces for energy savings. This work investigates the potential energy savings of occupancy sensors in hallways, stairwells, seminar rooms and lavatories of an education building. Lighting is one of the largest consumers of energy in the building industry and these space types are often fully illuminated for long periods of vacancy. Lighting is for the user, not the building. Discussions centre around light use habits, energy saving behaviours and sensor technology such as time delay and daylight sensors. The experiment uses wireless light sensors and PIR sensors to measure light energy use and occupant use of 20 intermittent use spaces. A user survey was planned to run alongside the experiment to investigate user perceptions of changes in lighting but was discontinued due to unresolved software issues. Results of the experiment encouraged the use of occupancy sensors in intermittent use spaces. Lavatories attained highest energy saving potential 54%, seminar rooms highest annual cost savings per fitting $15.47 and highest annual energy savings 482kWh and hallways calculated the quickest payback of 8.6 years. Hallways, stairwells, seminar rooms and lavatories all offer potential for energy savings, supporting the theoretical ideas and success of occupancy sensors in intermittent use spaces.</p>


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


Author(s):  
N.Sujith Prasanna ◽  
Dr.J.Nagesh Kumar

Energy cost is significant in many of the manufacturing activities. The efficiency of energy use is quiet low as there are substantial visible and hidden losses. Visible losses can be easily identified and corrective action can be taken. However hidden and indirect losses form a sizeable portion of the losses. Identifying these losses is not easy and requires an integrated approach which includes thorough study of process, operations and their interactions with energy use. Industries across sectors have implemented lean management principles which target various wastes occurring in the plant. This paper discusses case studies which highlight the exploitation of lean tools as a means for unearthing hidden energy saving potential that often go unnoticed. In addition to the energy savings which results in improved profits and competitiveness, the approach also aids the industry to pursue a path of sustainable manufacturing.


2021 ◽  
Vol 288 ◽  
pp. 01109
Author(s):  
Alexander Semenov ◽  
Yuriy Bebikhov ◽  
Ayaal Egorov ◽  
Vladislav Shevchuk ◽  
Marina Glazun ◽  
...  

The paper presents the evaluation of the implementation of innovative methods of energy savings in electric drive and power supply systems at mining enterprises. The evaluation involves mathematical simulation and instrumental monitoring of the defined indicators that allow obtaining a multiplier economic benefit through the appropriate approach to the implementation and subsequent exploitation of energy-saving technologies. For this purpose, the potential of energy savings in industry in general, and at mining enterprises in particular, is shown. Such indicators as power consumption in mining, the dynamics of power losses in public grids, specific power consumption for lighting and household needs, specific power consumption for lifting and supplying water, as well as for sewage treatment were evaluated. As an example, such measures as reactive power compensation, the introduction of frequency-controlled electric drive systems, the development and implementation of the systems for continuous monitoring of power quality indicators were considered pointwise (at some sites of enterprises). The mathematical simulation method was implemented using the MatLab software package. The instrumental monitoring was carried for 7 days with a ten-minute interval. As a result of the assessment of such measures, the total economic benefit approaching to 9.0 million rubles a year was obtained.


Sign in / Sign up

Export Citation Format

Share Document