A Numerical Algorithm and a Graphical Method to Size a Heat Exchanger

Author(s):  
Torsten Berning

This paper describes the development of a numerical algorithm and a graphical method that can be employed in order to determine the overall heat transfer coefficient inside heat exchangers. The method is based on an energy balance and utilizes the spreadsheet application software Microsoft Excel™. The application is demonstrated in an example for designing a single pass shell and tube heat exchanger that was developed in the Department of Materials Technology of the Norwegian University of Science and Technology (NTNU) where water vapor is superheated by a secondary oil cycle. This approach can be used to reduce the number of hardware iterations in heat exchanger design.

Author(s):  
Igor Martic ◽  
Aleksandar Maslarevic ◽  
Nikola Milovanovic ◽  
Miloš Markovic

A general procedure for heat exchanger design has been presented in the Heat Exchanger Design Handbook (HEDH) [1], but no precise criterion for determining baffle cut nor baffle  spacing has been offered, and the emphasis is only on heat exchanger’s permissible range of application. In this paper, an optimization program has been used to calculate pressure drop, fluid velocity, heat power, overall heat transfer coefficient and middle temperature difference for various baffle cut and baffle spacing for the same type of heat exchanger, using the procedure in HEDH. This could be considered as complementary to the HEDH recommendations and can be used by designers and, generally, engineers for determining the right baffle cut and baffle spacing for their specific cases.


Author(s):  
Shamkuwar S.C ◽  
◽  
Nitin Chopra ◽  
Mihir Kulkarni ◽  
Nikhil Ahire ◽  
...  

The main objective of the paper is to compare the performance of Shell and tube heat exchanger (STHE) and Plate heat exchanger (PHE) used in chillers. The paper deals with experimental investigation and comparison, which is based on actual testing of STHE and PHE. Both heat exchangers were designed and tested for a heat load of 6000 kcal/hr. In both types of heat exchangers, the primary working fluid used is Refrigerant R22 and secondary working fluid used is water. Theoretical analysis shows that PHE has a 9.67 % less heat transfer area than STHE. Experimental results show that overall heat transfer coefficient (OHTC) for PHE is higher than STHE by 30.96%. The paper also includes a comparison of the heat transfer rate (Q) of the two heat exchangers experimentally.


AIChE Journal ◽  
2016 ◽  
Vol 63 (6) ◽  
pp. 1907-1922 ◽  
Author(s):  
Caroline de O. Gonçalves ◽  
André L. H. Costa ◽  
Miguel J. Bagajewicz

2015 ◽  
Vol 62 (4) ◽  
pp. 509-522 ◽  
Author(s):  
R. Dharmalingam ◽  
K.K. Sivagnanaprabhu ◽  
J. Yogaraja ◽  
S. Gunasekaran ◽  
R. Mohan

Abstract Cooling is indispensable for maintaining the desired performance and reliability over a very huge variety of products like electronic devices, computer, automobiles, high power laser system etc. Apart from the heat load amplification and heat fluxes caused by many industrial products, cooling is one of the major technical challenges encountered by the industries like manufacturing sectors, transportation, microelectronics, etc. Normally water, ethylene glycol and oil are being used as the fluid to carry away the heat in these devices. The development of nanofluid generally shows a better heat transfer characteristics than the water. This research work summarizes the experimental study of the forced convective heat transfer and flow characteristics of a nanofluid consisting of water and 1% Al2O3 (volume concentration) nanoparticle flowing in a parallel flow, counter flow and shell and tube heat exchanger under laminar flow conditions. The Al2O3 nanoparticles of about 50 nm diameter are used in this work. Three different mass flow rates have been selected and the experiments have been conducted and their results are reported. This result portrays that the overall heat transfer coefficient and dimensionless Nusselt number of nanofluid is slightly higher than that of the base liquid at same mass flow rate at same inlet temperature. From the experimental result it is clear that the overall heat transfer coefficient of the nanofluid increases with an increase in the mass flow rate. It shows that whenever mass flow rate increases, the overall heat transfer coefficient along with Nusselt number eventually increases irrespective of flow direction. It was also found that during the increase in mass flow rate LMTD value ultimately decreases irrespective of flow direction. However, shell and tube heat exchanger provides better heat transfer characteristics than parallel and counter flow heat exchanger due to multi pass flow of nanofluid. The overall heat transfer coefficient, Nusselt number and logarithmic mean temperature difference of the water and Al2O3 /water nanofluid are also studied and the results are plotted graphically.


Author(s):  
Michel De Paepe ◽  
Christophe T’Joen ◽  
Arnold Janssens ◽  
Marijke Steeman

Earth-air heat exchangers are often used for (pre)heating or (pre)cooling of ventilation air in low energy or passive house standard buildings. Several studies have been published in the passed about the performance of these earth-air heat exchangers [1–8]. Often this is done in relation to the building energy use. Several software codes are available with which the behaviour of the earth-air heat exchanger can be simulated. De Paepe and Janssens published a simplified design methodology for earth-air heat exchangers, based on thermal to hydraulic performance optimisation [7]. Through dynamic simulations and measurements it was shown that the methodology is quite conservative [9–10]. Hollmu¨ller added an earth-air heat exchanger model to TRNSYS [11]. In stead of using earth-air heat exchangers, earth-water heat exchangers are now getting more attention. In this system the ventilation air is indirectly cooled/heated with the water flow in a fin-tube heat exchanger in the inlet of the ventilation channel. The water-glycol mixture transfers heat with the earth by flowing through e.g. a polyethylene tube. In the second part of this paper a design methodology is first derived and then applied to this type of system.


Author(s):  
Majid Amidpour ◽  
Abazar Vahdat Azad

In this paper, the new approach of Constructal theory has been employed to design shell and tube heat exchangers. Constructal theory is a new method for optimal design in engineering applications. The purpose of this paper is optimization of shell and tube heat exchangers by reduction of total cost of the exchanger using the constructal theory. The total cost of the heat exchanger is the sum of operational costs and capital costs. The overall heat transfer coefficient of the shell and tube heat exchanger is increased by the use of constructal theory. Therefore, the capital cost required for making the heat transfer surface is reduced. Moreover, the operational energy costs involving pumping in order to overcome frictional pressure loss are minimized in this method. Genetic algorithm is used to optimize the objective function which is a mathematical model for the cost of the shell and tube heat exchanger and is based on constructal theory. The results of this research represent more than 50% reduction in costs of the heat exchanger.


2011 ◽  
Vol 134 (1) ◽  
Author(s):  
Natalia Petrova ◽  
Abdel-Hakim Bouzid

Despite the fact that multipass shell-and-tube heat exchangers operating at high temperature are subject to frequent problems related to flange sealing, there is neither detailed explanations for the reasons of the failures nor an adequate solution to this problem. Specific geometry of multipass heat exchangers and the temperature difference between the inlet and the outlet fluids is responsible for the existence of a thermal circumferential gradient at the shell-to-channel bolted joint. However, existing flange design methods do not address nonaxisymmetrical temperature loading of the flanged joint assembly. The circumferential thermal gradient, as the cause of frequent failures to seal the flanged joints, is ignored. This paper outlines the analytical modeling of a flanged joint with a tube sheet of a multipass heat exchanger subjected to a nonaxisymmetrical thermal loading. A shell-and-tube heat exchanger of 51 in. diameter with cocurrent flow was used for analysis. The main steps of the theoretical analysis used for the determination of the circumferential temperature profiles and the thermal expansion displacements and distortions of the bolted joint components are given. The results from the proposed analytical model are compared with those obtained from finite element models.


Author(s):  
Paritosh Singh

Abstract: Research in convective heat transfer using suspensions of nanometer sized solid particles in a base fluid started only over the past decade. Recent investigations on nanofluids, as such suspensions are often called, indicate that the suspended nanoparticles markedly change the transport properties and heat transfer characteristics of the suspension. The very first part of the research work summarizes about the various thermo physical properties of Al2O3 Nanofluid. In evacuated tube solar water heating system nanofluids are used as primary fluid and DM water as secondary fluid in Shell and Tube Heat Exchanger. The experimental analysis of Shell and Tube heat exchanger integrated with Evacuated tube solar collector have been carried out with two types of primary fluids. Research study of shell and tube heat exchanger is focused on heat transfer enhancement by usage of nano fluids. Conventional heat transfer fluids have inherently low thermal conductivity that greatly limits the heat exchange efficiency. The result of analysis shows that average relative variation in LMTD and overall heat transfer coefficient is 24.56% and 52.0% respectively. The payback period of system is reduced by 0.4 years due to saving is in replacement cost of Evacuated Tube Collector. Keywords: ETC; Nanofluid; LMTD; Thermal Conductivity; Overall heat transfer coefficient


2020 ◽  
Vol 7 (2) ◽  
pp. F1-F7
Author(s):  
E. Nogueira

The objective of the work is to obtain the outlet temperatures of the fluids in a shell and tube heat exchanger. The second law of thermodynamics is applied through the concepts of efficiency, effectiveness, and irreversibility to analyze the results. Water flows in the shell, and a mixture of water-ethylene glycol is associated with fractions of nanoparticles flows in the tube. Water enters the shell at 27 °C, and the mixture comes to the tube at 90 °C. The mass flow is kept fixed in the shell, equal to 0.23 kg/s, and varies between 0.01 kg/s to 0.50 kg/s. Volume fractions equal to 0.01, 0.10, and 0.25 were considered for analysis, for both nanoparticles from Ag and Al2O3. Results for Reynolds number, heat transfer rate, efficiency, effectiveness, and irreversibility are presented for critique, discussion, and justification of the output data found. It is shown that the flow regime has a significant effect on the performance of the analyzed heat exchanger. Keywords: thermodynamics, second law, ethylene glycol, volume fraction.


Sign in / Sign up

Export Citation Format

Share Document