Guide Vanes Inference on Hydraulic Characteristics of Tubular Pump

Author(s):  
Jin Yan ◽  
Liu Chao ◽  
Takaharu Tanaka

The blade number of pump guide vane is an important factor that affects hydraulic characteristics of the pumping system, since the diffusion angle after the impeller is larger than as usual. It is necessary to pay more attention for its calculation and analysis. By CFD method the numeric simulation was conducted to a bulb tubular pump with different guide vane blades and the three dimensional flow fields within whole passage of pumping system was obtained. There are five different number of guide vane blades (4 blades, 5 blades, 7 blades, 8 blades and improved 5 blades) selected for the simulation and performance prediction. The influences of the guide vanes numbers on the system performance are analyzed. The hydraulic losses increases with the increase of the number of guide vane blades while the efficiency of pumping system is not fully comply with this relationship. The system efficiency for which 5 guide vanes were adopted is higher than others with different number of guide vane blades; also the velocity and the pressure distribution of flow fields are more uniform. The system efficiency for which 5 improved guide vanes is the highest with lowest hydraulic losses. The recommended alternative of guide vane is presented for the pump impeller.

Author(s):  
Lingyu Li ◽  
Yuan Zheng ◽  
Daqing Zhou ◽  
Zihao Mi

The head of low-head hydropower stations is generally higher than 2.5m in the world, while micro-head hydropower resources which head is less than 2.5m are also very rich. In the paper, three-dimensional CFD method has been used to simulate flow passage of the micro-head bulb turbine. The design head and unit flow of the turbine was 1m and 3m3/s respectively. With the numerical simulation, the bulb turbine is researched by analyzing external characteristics of the bulb turbine, flow distribution before the runner, pressure distribution of the runner blade surface, and flow distribution of the outlet conduit under three different schemes. The turbine in second scheme was test by manufactured into a physical model. According to the results of numerical simulation and model test, bulb turbine with no guide vane in second scheme has simpler structure, lower cost, and better flow capacity than first scheme, which has traditional multi-guide vanes. Meanwhile, efficiency of second scheme has just little decrease. The results of three dimensions CFD simulation and test results agree well in second scheme, and higher efficiency is up to 77% which has a wider area with the head of 1m. The curved supports in third scheme are combined guide vanes to the fixed supports based on 2nd scheme. By the water circulations flowing along the curved supports which improve energy transformation ability of the runner, the efficiency of the turbine in third scheme is up to 82.6%. Third scheme, which has simpler structure and best performance, is appropriate for the development and utilization of micro-head hydropower resources in plains and oceans.


Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3354 ◽  
Author(s):  
Huixiang Chen ◽  
Daqing Zhou ◽  
Yuan Zheng ◽  
Shengwen Jiang ◽  
An Yu ◽  
...  

To obtain the flow mechanism of the transient characteristics of a Kaplan turbine, a three-dimensional (3-D) unsteady, incompressible flow simulation during load rejection was conducted using a computational fluid dynamics (CFD) method in this paper. The dynamic mesh and re-meshing methods were performed to simulate the closing process of the guide vanes and runner blades. The evolution of inner flow patterns and varying regularities of some parameters, such as the runner rotation speed, unit flow rate, unit torque, axial force, and static pressure of the monitored points were revealed, and the results were consistent with the experimental data. During the load rejection process, the guide vane closing behavior played a decisive role in changing the external characteristics and inner flow configurations. In this paper, the runner blades underwent a linear needle closure law and guide vanes operated according to a stage-closing law of “first fast, then slow,” where the inflection point was t = 2.3 s. At the segment point of the guide vane closing curve, a water hammer occurs between guide vanes and a large quantity of vortices emerged in the runner and the draft tube. The pressure at the measurement points changes dramatically and the axial thrust rises sharply, marking a unique time in the transient process. Thus, the quality of a transient process could be effectively improved by properly setting the location of segmented point. This study conducted a dynamic simulation of co-adjustment of the guide vanes and the blades, and the results could be used in fault diagnosis of transient operations at hydropower plants.


Processes ◽  
2021 ◽  
Vol 9 (9) ◽  
pp. 1555
Author(s):  
Juan Pablo Hurtado ◽  
Bryan Villegas ◽  
Sebastián Pérez ◽  
Enrique Acuña

The connection between an intake fan and a ventilation shaft must be designed in such a way that it minimizes the energy waste due to singularity losses. As a result, the questions of which radius of curvature to use and if guide vanes have to be included need to be answered. In that case, the variables such as the number, upstream and downstream penetration length, radius of curvature, and width of the vanes, need to be defined. Although this work is oriented to mine ventilation, these questions are usually valid in other engineering applications as well. The objective of this study is to define the previously mentioned variables to determine the optimal design combination for the radius/diameter relationship (r/D). Computational fluid dynamics was used to determine the shock loss factor of seven elbow curvature ratios for a 3 m diameter duct and fan, with and without guide vanes to estimate the best performing configuration and, therefore, to maximize the fan airflow volume. The methodology used consisted of initially developing models in 2D geometries, to optimize the meshing and the CPU use, and studying separately the number of vanes, upstream and downstream penetration, radius of curvature, and width of the vanes for each curvature ratio (r/D). Then, the best-performing variable combinations for each curvature ratio were selected to be simulated and studied with the 3D geometries. The application of the guide vane designs for three-dimensional simulated geometries is presented, first without and then with guide vanes, including the shock loss factors obtained. The methodology and obtained results allowed quantifying the energy savings and to reduce the CFD simulations steps required to optimize the design of the elbow and guide vanes. The results obtained cannot be used with elbows in exhaust fans, because fluid dynamics phenomena are different.


Author(s):  
Zhou Daqing ◽  
Bo Qu ◽  
Zheng Yuan

In the paper, CFD method is applied to investigate model propeller turbine performance under different guide vane opening. First, the whole passage geometric models of model propeller turbine have been built with 0° runner blade under five kinds of guide vane opening, and subdivided with about 1.78 million cells of unstructured mesh. Then, three dimensional turbulent flow computations are made at the water head of H = 1m and the runner speed of n = 217.4 r/min, with the two turbulent models, RNG k-ε and Spalart-Allmadas. Furthermore, the curves of moment value and axial hydraulic thrust value are plotted and compared with experimental curves, which shows that numerical results agree well with experimental data, and Spalart-Allmadas model has better precision than RNG k-ε model. Finally, the flow fields of different parts in the turbine passage are displayed and analyzed respectively under the large, normal and small guide vane opening, which shows the fact that the rotating direction of vortex in the axial diffuse of draft tube is opposite by comparing the large opening with the small opening, and the flow field is in disorder and unsteady especially under the small opening. On the whole, CFD method has many unique advantages and has played more and more important roles on the investigations of hydro turbine performance.


Author(s):  
Yan Jin ◽  
Junxin Wu ◽  
Hongcheng Chen ◽  
Chao Liu

Diffuser vane of tubular pump is different with that of the axial flow pump, since the diffusion angle after the impeller is larger than as usual, which is an important part of bulb tubular pump system. By calculating the hydraulic loss of each part of bulb tubular pump system, it is found that the hydraulic loss of diffuser vane is in large proportion of the whole hydraulic loss. For this situation, focuses on the design parameters of diffuser vane such as diffuser vane length, unilateral edge diffusion angle, equivalent diffusion angle are necessary. In this paper, CFD method is used to simulate the turbulent flow in a bulb tubular pumping system with two different diffuser vanes. The three dimensional flow fields in the whole passage of pumping system with different diffuser vanes are obtained. The results show that all the main geometry parameters of the diffuser vane design affect the performances of tubular pumping system, it should be chosen the parameters reasonably based on the actual situation.


Author(s):  
M. E. Rife ◽  
F. Barbarossa ◽  
A. B. Parry ◽  
J. S. Green ◽  
L. di Mare

Flow in annular ducts is sensitive to the presence of downstream blockages which can cause flow non-uniformities propagating far upstream of the blocking body. These effects can be exacerbated in swirling flows where a cascade of uniform guide vanes is present upstream of the blockage. This work uses two- and three-dimensional boundary singularity methods to model and optimise a guide vane cascade geometry to minimise the upstream velocity distortion. Starting from a uniform cascade, the geometry is modified to provide a uniform upstream velocity distribution and minimised blade-to-blade loading in two dimensions. The new geometry is then extrapolated to a three-dimensional annulus. A three-dimensional tool is used to further modify the geometry in three dimensions to minimise the velocity distortion in the whole annulus upstream of the cascade.


Author(s):  
Honggang Fan ◽  
Qingfeng Ji ◽  
Weili Liao ◽  
Haixia Yang

The unit of a Pumped Storage Power Station experienced abnormal noise and vibration in the guide vanes at the slight opening when the pump turbine was in the process of startup in the pumping mode. Based on this phenomena, the three dimensional model of the pump turbine was established, RNG k-epsilon two equations turbulence model was selected for the flow numerical simulation in the pump turbine because this model can simulate both the flow separation and vortex dynamics, and it is more accurate in the near wall areas. The governing equations were discretized with the finite volume method. The computation was carried out with three steps, 1.steady calculation, 2.unsteady calculation with constant guide vane opening, 3.unsteady calculations with the increase of the opening of guide vanes, by using the results of the last step as the initial condition. According to the three dimensional simulation results, the main flow between the guide vanes was deflected from attaching to the one vane to the other vane with the opening of the guide vanes. The calculation of complete 3D flow indicated that the deflections of the flows between the different adjacent guide vanes were basically the same, however, the deflections starting times had a few differences. The variation of the torque on the guide vane was also investigated, and the results shown the abrupt changes occurred during the deflection process of the main flow. When the torque produced by the servomotor cannot adapt quickly enough to the abrupt changes, the vibration and loud scrape noise might occur.


2000 ◽  
Vol 123 (2) ◽  
pp. 211-218 ◽  
Author(s):  
Tong-Miin Liou ◽  
Hsin-Li Lee ◽  
Chin-Chun Liao

Three-dimensional flowfields in a 60-deg curved combustor inlet duct of rectangular cross-section with and without guide vanes were measured using Laser-Doppler velocimetry for the longitudinal, radial, and spanwise velocity components. The Reynolds number based on the bulk mean velocity and hydraulic diameter was 2.53×104. The main parameters examined were the guide-vane number and Reynolds number. The results show that to completely eliminate flow separation in the curved combustor inlet three guide vanes should be installed. The critical Reynolds number for the absence of the flow separation is found to decrease with increasing product of radius and aspect ratios. In addition, it is found that in most regions the maximum radial mean velocity, difference between radial and spanwise normal stress, and the turbulent kinetic energy decrease with increasing guide-vane number. A rationale for the absence of flow separation in the one-vane case predicted by previous researchers is also provided.


Author(s):  
Nils Moser ◽  
Peter Steinhoff ◽  
Franz Joos

The numerically and experimentally investigated industrial steam turbine control stage is derived from a real design. Due to the production process and costs of the guide vanes for control stages of steam turbines the flowpath profiling is rotationally symmetric. However the combination of the two-dimensional shroud contour and the flow deflection in the guide vane results in a fully three-dimensional end wall contour having a strong influence on the secondary flow features in the turbine control stage. To obtain an improved profile for the nozzle shroud the reduction of the total pressure loss over the guide vanes is taken as an optimization criterion. The three-dimensional contour generates a diffuser flowpath between the suction and the pressure side of two guide vanes perpendicular to the main flow direction. This diffuser geometry affects the pressure distribution over the guide vane and therefore the formation mechanisms of secondary flows. For the experimental and numerical investigations a baseline shroud design and two additional profiled contours are analyzed in detail. The control stage test rig is operated with air and is capable to represent a wide range of operating conditions. The measurements show a considerable increase of the stage efficiency and power output. The effect of the flowpath profiling on the pressure distribution over the guide vane is clearly proved.


Author(s):  
C. Cravero ◽  
A. Satta ◽  
M. Marini

A CFD method, previously developed by the authors for compressible flows, has been modified through a preconditioning technique to account for purely incompressible flows. Such a code is used to compute three-dimensional flows in a mixed flow pump impeller at design and off-design conditions. The results of the inviscid flow approach are critically discussed by comparison to available experimental data.


Sign in / Sign up

Export Citation Format

Share Document