3-D Conjugate Flow and Heat Transfer Investigations of a Film-Cooled Turbine Guide Vane With Different Blowing Ratios

Author(s):  
Dieter E. Bohn ◽  
Tom Heuer ◽  
Karsten A. Kusterer

Film-cooling has become a widely used cooling method in present day gas turbines. Cooling gas ejection at the leading edge serves to protect the entire vane surface from contact with the hot gas. With doing this, material temperatures are reduced in order to guarantee an economically acceptable life span of the vane. This paper describes the application of a numerical method for the conjugate calculation of internal and external fluid flows and the heat transfer in and through the blade walls of a film-cooled turbine guide vane. The advantage of this approach is that it is possible to predict fluid flow properties and wall temperatures without the need for additional heat transfer conditions or temperature conditions at the external surfaces of the vane. This is a great advantage because the desired data are either unknown or not available for the calculation in the design process of new cooled blades or vanes. In a complete calculation of external and internal flows, no additional boundary conditions at the internal surfaces of the cooling geometry are needed either. Another advantage is the interaction of fluid flow and heat transfer which is taken into account by the conjugate calculation. In the 3-D numerical experiment to be presented, the influence of leading edge cooling fluid ejection on the temperature distribution in the vane material is investigated. The cooling fluid is ejected through two slots at the leading edge. The calculations are performed for three blowing ratios in order to investigate the efficiency of the cooling method. Realistic temperature ratios of cooling-fluid flow and main flow are considered. Such information is very useful in the aero thermal design process of new cooling configurations, since the amount of experimental work can be minimized. The results show the influence of complex 3-D flow phenomena (e.g. passage vortex) on the cooling fluid distribution on the vane surface as a function of the chosen blowing factor. Due to the influence of the passage vortex, the cooling fluid is displaced and leaves the vane surface near the side-wall uncovered against the hot gas. Furthermore, cooling fluid displacement on the pressure side according to the ejection slot geometry leads to another unprotected region on the vane surface. These effects have severe consequences on the thermal load of the vane and can reduce its life span.

Author(s):  
Dieter E. Bohn ◽  
Volker J. Becker ◽  
Agnes U. Rungen

This paper presents investigations of the development for a shower-head cooling configuration for a modern industrial turbine guide vane. One aim is to find suitable locations for cooling gas ejection with the lowest cooling gas mass flow possible. The investigations begin with a numerical experiment. After the prediction of a suitable configuration and operating parameters, the aerodynamics are investigated experimentally using a non-intrusive LDA technique. Once the aerodynamics had been validated, the numerical experiments were expanded to a thermal analysis of the vane. Our conjugate flow and heat transfer simulation enables thermal analysis of the vane body without us having to derive any heat transfer data beforehand. The calculations were performed for a temperature ratio of 0.5 between cooling gas and main stream. This temperature ratio is similar to the operating conditions found in current designs. The stagnation line moves under the influence of cooling gas ejection, which significantly influences the cooling gas distribution on the vane surface. The temperature distribution inside the vane is compared to a non-cooled test case. The simulation shows that the temperature peaks at the leading edge are reduced by between 18% and 44%.


Author(s):  
Dieter E. Bohn ◽  
Christian Tu¨mmers

The aerodynamics and aerothermics of a transonic convection-cooled turbine guide vane are investigated by application of a conjugate fluid flow and heat transfer solver, CHT-Flow. The code developed at the Institute of Steam and Gas Turbines, Aachen University, does not need any heat transfer data beforehand. Since the numerical results for the uncoated vane showed good agreement with experimental data, numerical investigations are extended for the coated vane. The investigated configuration consists of an APS (Athmospheric Plasma Spray) layer, while the external vane shape is preserved. For the coated configuration a parametric study of the cooling fluid mass flow has been performed with the aim of a smoothed temperature distribution in the blade material. Furthermore, with the help of a simplified thermal stress analysis the influence of the reduced cooling fluid mass flow on the thermal stresses in the blade material will be discussed in detail.


2018 ◽  
Vol 140 (12) ◽  
Author(s):  
Zhigang Li ◽  
Luxuan Liu ◽  
Jun Li ◽  
Ridge A. Sibold ◽  
Wing F. Ng ◽  
...  

This paper presents a detailed experimental and numerical study on the effects of upstream step geometry on the endwall secondary flow and heat transfer in a transonic linear turbine vane passage with axisymmetric converging endwalls. The upstream step geometry represents the misalignment between the combustor exit and the nozzle guide vane endwall. The experimental measurements were performed in a blowdown wind tunnel with an exit Mach number of 0.85 and an exit Re of 1.5×106. A high freestream turbulence level of 16% was set at the inlet, which represents the typical turbulence conditions in a gas turbine engine. Two upstream step geometries were tested for the same vane profile: a baseline configuration with a gap located 0.88Cx (43.8 mm) upstream of the vane leading edge (upstream step height = 0 mm) and a misaligned configuration with a backward-facing step located just before the gap at 0.88Cx (43.8 mm) upstream of the vane leading edge (step height = 4.45% span). The endwall temperature history was measured using transient infrared thermography, from which the endwall thermal load distribution, namely, Nusselt number, was derived. This paper also presents a comparison with computational fluid dynamics (CFD) predictions performed by solving the steady-state Reynolds-averaged Navier–Stokes with Reynolds stress model using the commercial CFD solver ansysfluent v.15. The CFD simulations were conducted at a range of different upstream step geometries: three forward-facing (upstream step geometries with step heights from −5.25% to 0% span), and five backward-facing, upstream step geometries (step heights from 0% to 6.56% span). These CFD results were used to highlight the link between heat transfer patterns and the secondary flow structures and explain the effects of upstream step geometry. Experimental and numerical results indicate that the backward-facing upstream step geometry will significantly enlarge the high thermal load region and result in an obvious increase (up to 140%) in the heat transfer coefficient (HTC) level, especially for arched regions around the vane leading edge. However, the forward-facing upstream geometry will modestly shrink the high thermal load region and reduce the HTC (by ∼10% to 40% decrease), especially for the suction side regions near the vane leading edge. The aerodynamic loss appears to have a slight increase (0.3–1.3%) because of the forward-facing upstream step geometry but is slightly reduced (by 0.1–0.3%) by the presence of the backward upstream step geometry.


Author(s):  
Dieter E. Bohn ◽  
Volker J. Becker

This paper presents the numerical investigations of the flow and heat transfer of two configurations of a transonic turbine guide vane. The basic configuration is a vane with convection cooling. The second configuration is additionally coated with a thermal barrier consisting of ZrO2. The results are obtained with a conjugate heat transfer and flow computer code that has been developed at the Institute of Steam and Gas Turbines. Measurement data is available for the basic configuration and the computational results are compared to the experimental results. The results show very good agreement between calculated and measured vane surface temperatures. The trailing edge turns out to be subjected to high thermal loads as it is too thin to be cooled effectively. Secondary flow phenomena like the passage vortex and the corner vortex and their impact on the temperature distribution are discussed. The ZrO2 coating is calculated for a thickness of 300μm. The substrate material temperatures are lowered by about 20 K–29 K in the stagnation point area and by about 27 K–43 K in the shock area on the suction side. At the trailing edge, the coating on the suction side and on the pressure side hardly influences the metal temperature.


Author(s):  
Bibin John ◽  
Sudhanva Kusuma Chandrashekhara ◽  
Vivekkumar Panneerselvam

Aero-thermodynamic analysis of a cylindrical leading edge placed in a hypersonic stream is carried out using an in-house developed conjugate heat transfer (CHT) solver. Isotropic and functionally graded materials (FGM) are tested as heat shields to understand the effects of the material property on the flow structure and aerodynamic heating associated with the mutual coupling of fluid flow and heat transfer. A simplified partitioned approach is employed to couple the independently developed fluid flow and heat transfer solvers to perform conjugate heat transfer studies. This framework employs a cell-centred finite volume formulation with an edge-based algorithm. Both strong and loose coupling algorithms are implemented for the data transfer across the fluid–solid interface. A test case of hypersonic flow over a cylindrical leading edge composed of an isotropic material is considered to validate the accuracy and correctness of numerical formulation adopted in the in-house solver. The significance of solid domain materials on the conjugate heat transfer has been studied by considering both isotropic material and FGM. The loosely coupled CHT solver required 10 times less simulation time when compared with the strongly coupled CHT solver. The interface heat flux evolution over time showed a decreasing trend, whereas an increasing trend was for the interface temperature. The current study strongly recommends CHT analysis for the design of thermal protection system of space vehicles. The thermal performance of FGMs composed of various volume fractions of Zirconia and Titanium alloy (Ti6Al4V) is assessed. The temperature distributions obtained from the CHT analysis shows that FGM with a power index of unity is a good material choice for thermal protection systems.


Author(s):  
Dieter E. Bohn ◽  
Volker J. Becker ◽  
Karsten A. Kusterer ◽  
Agnes U. Rungen

This paper presents the experimental investigation of the flow and the numerical analysis of the flow and heat transfer in a turbine guide vane with showerhead cooling for two different blowing ratios. The aerodynamic results are compared with those of the experiments. Starting with a showerhead design of two rows of ejection holes, two additional rows have to be used in an enhanced design due to hot gas contact in the leading edge area. Thus, the cooling gas mass flow is doubled when keeping the blowing ratio constant at m = 1.5. Lowering the amount of cooling gas needed whilst still guaranteeing sufficient cooling is the motivation for the analysis of the influence of a lower blowing ratio on the cooling efficiency. The investigated blowing ratios are m = 1.5 and m = 1.0. The experiments are conducted using a non-intrusive LDA technique. The numerical results are gained with a conjugate heat transfer and flow computer code that has been developed at the Institute of Steam and Gas Turbines. The results show that the blowing ratio has to be chosen carefully as the leading edge flow pattern and the heat transfer are strongly influenced by the blowing ratio. Lower blowing ratios lead to a better attachment of the cooling film and thus they hardly disturb the main flow. With the lower blowing ratio, the material temperature increases up to 1.5% of the total inlet temperature in the leading edge area on the pressure side, whereas it decreases locally for about 0.8% for the lower blowing ratio on the suction side. This is due to the enhanced attachment of the cooling gas film.


Sign in / Sign up

Export Citation Format

Share Document