scholarly journals The Mach 2 Axial Flow Compressor Stage

1975 ◽  
Author(s):  
F. A. E. Breugelmans

A supersonic compressor stage has been designed for a high pressure ratio at a tip relative inlet Mach number of 2. The stage was operated in the original configuration, but serious inlet stall occurred at part-speed operation. An inlet blockage ring, a bleed system and a variable geometry inlet guide vane have been analyzed and applied to this configuration. The results obtained with the bleed system in the complete stage are presented. The rotor performance is discussed and compared with the stage performance.

Author(s):  
Songtao Wang ◽  
Xiaoqing Qiang ◽  
Weichun Lin ◽  
Guotai Feng ◽  
Zhongqi Wang

In order to design high pressure ratio and highly loaded axial flow compressor, a new design concept based on Highly-Loaded Low-Reaction and boundary layer suction was proposed in this paper. Then the concept’s characteristics were pointed out by comparing with the MIT’s boundary layer suction compressor. Also the application area of this design concept and its key technic were given out in this paper. Two applications were carried out in order to demonstrate the concept. The first application was to redesign a low speed duplication-stage axial flow compressor into a single stage. The second one was a feasibility analysis to decrease an 11 stage axial compressor’s stage count to 7 while not changing its aerodynamic performance. The analysis result showed that the new design concept is feasible and it can be used on high pressure stage of the aero-engine, compressor of ground gas turbine (except the transonic stage) and high total pressure ratio blower.


Author(s):  
T. H. Okiishi ◽  
G. H. Junkhan ◽  
G. K. Serovy

Aerodynamic performance of a variable-geometry axial-flow compressor inlet guide vane configuration for a gas turbine unit was determined in a series of annular cascade tests. The variable-geometry vanes used uncambered, symmetrical airfoil sections as the basic blade profile with the rear 70 percent of the vane profile movable as a trailing-edge flap. Vane flap mechanical setting angles of 0 to 50 deg measured from the axial direction were possible, and performance parameters were determined over this range of angles. Turning angles followed a general trend obtained with Carter’s rule for accelerating cascades with the presently measured values tending to be lower than those obtained with Carter’s rule at higher setting angles. For large camber angles (greater than 35 deg) zero-incidence blade element total-pressure loss coefficients for the 50 percent passage location of the flapped vanes tested were higher than those that might have been obtained with a continously cambered vane row of the same solidity and camber.


Author(s):  
Cleverson Bringhenti ◽  
Jesuino Takachi Tomita ◽  
Joa˜o Roberto Barbosa

This work presents the performance study of a 1 MW gas turbine including the effects of blade cooling and compressor variable geometry. The axial flow compressor, with Variable Inlet Guide Vane (VIGV), was designed for this application and its performance maps synthesized using own high technological contents computer programs. The performance study was performed using a specially developed computer program, which is able to numerically simulate gas turbine engines performance with high confidence, in all possible operating conditions. The effects of turbine blades cooling were calculated for different turbine inlet temperatures (TIT) and the influence of the amount of compressor-bled cooling air was studied, aiming at efficiency maximization, for a specified blade life and cooling technology. Details of compressor maps generation, cycle analysis and blade cooling are discussed.


1984 ◽  
Vol 106 (2) ◽  
pp. 337-345
Author(s):  
B. Lakshminarayana ◽  
N. Sitaram

The annulus wall boundary layer inside the blade passage of the inlet guide vane (IGV) passage of a low-speed axial compressor stage was measured with a miniature five-hole probe. The three-dimensional velocity and pressure fields were measured at various axial and tangential locations. Limiting streamline angles and static pressures were also measured on the casing of the IGV passage. Strong secondary vorticity was developed. The data were analyzed and correlated with the existing velocity profile correlations. The end wall losses were also derived from these data.


Author(s):  
Theoklis Nikolaidis ◽  
Periclis Pilidis ◽  
J. A. Teixeira ◽  
V. Pachidis

A numerical approach was used to evaluate the liquid water film thickness and its motion on an axial flow compressor rotor blade under water ingestion conditions. By post-processing blading data and using computer programs to create the blades and their computational grid, the global computational domain of the first stage of an axial flow compressor was built. The flow field within the domain was solved by CFX-Tascflow, which is a commercial CFD code commonly used in turbomachinery. The computational domain consists of an extended inlet, an inlet guide vane, a rotor and a stator blade. Having solved the flow field at Design Point, the inlet guide vane blade was re-positioned to account for changes in idle speed. At that speed, the effects of water ingestion are expected to be more significant on gas turbine engine performance. Several cases with water ingestion were studied, changing parameters like water mass and compressor rotational speed. A FORTRAN computer program was created to calculate the water film height and speed. The extra torque needed by the compressor to keep running at the same rotational speed, was also calculated. The considerable increase in torque was confirmed by experimental observations according to which water ingestion had a detrimental effect on gas turbine operation.


1998 ◽  
Vol 4 (4) ◽  
pp. 217-231
Author(s):  
Heinz E. Gallus

Detailed results of unsteady flow measurements in a stator-rotor-stator assembly of an axial-flow turbine as well as an inlet guide vane-rotor-stator formation of an axial-flow compressor are presented in this paper.The measurements include the time-dependent 3-D velocity vector fields in the axial gaps between the blade rows by means of triple-hot wire-technique, furthermore the total pressure field downstream of the blade rows by means of semiconductor total pressure probes and the unsteady flow field determination in the rotor passages by LDV-technique. Special semiconductor pressure measurements along the casing all over the rotor tip clearance permit detailed discussion of the rotor tip clearance flows.The conclusion of the measured data provides a new and very instructive view of the physics of the unsteady blade-row interaction in axial-flow turbines and compressors.


Author(s):  
Hans Ma˚rtensson ◽  
Jo¨rgen Burman ◽  
Ulf Johansson

As the first design in a demonstration program for future fighter engine fans a 400 mm 1-1/2 stage fan has been designed and built. A new method including mechanical constraints for designing the blades and gas path is used for the first time on a new design. The approach closely integrates CFD for performance and FE methods for the structure. By this, advanced computational analyses affect the design from the early stages. A design that is successful in achieving good efficiency based on CFD as well as reasonable aeromechanical properties based on FE is derived. The fan incorporates a front frame (FF), variable inlet guide vane (VIGV), rotor 1 (R1) and stator 1 (S1).


Author(s):  
Levi André B. Vigdal ◽  
Lars E. Bakken

The introduction of variable inlet guide vanes (VIGVs) upfront of a compressor stage affects performance and permits tuning for off-design conditions. This is of great interest for emerging technology related to subsea compression. Unprocessed gas from the wellhead will contain liquid condensate, which affects the operational condition of the compressor. To investigate the effect of guide vanes on volume flow and pressure ratio in a wet gas compressor, VIGVs are implemented upfront of a centrifugal compressor stage to control the inlet flow direction. The guide vane geometry and test rig setup have previous been presented. This paper documents how changing the VIGV setting affects compressor performance under dry and wet operating conditions. The reduced performance effect and operating range at increased liquid content are of specific interest. Also documented is the change in the VIGV effect relative to the setting angle.


Sign in / Sign up

Export Citation Format

Share Document