Energy Consideration in the Micro-Extrusion of Aluminum Alloy 6063

Author(s):  
Sedthawatt Sucharitpwatskul ◽  
Numpon Mahayotsanun ◽  
Sujin Bureerat ◽  
Kuniaki Dohda

Abstract This paper investigated key factors influencing energy consumption in the micro-extrusion process. The considered factors were: extrusion ratio (ER), die angle (?), billet length (BL), bearing length (LB), coefficient of friction (COF), and die shift (DS). The finite element simulation was carried out to determine the extrusion energy required to complete one extrusion cycle. The simulation results showed that the increased values of all the considered factors (except the die shift) led to increased extrusion energy. The results also provided percentages of energy variation in steps, which helped evaluate the energy savings with regards to the crucial other production considerations. The percentage increase in energy consumption in the lower ER values was considered higher than those of, the higher ER values. Increasing die angle (?) from 60° to 90° barely affected the consumed energy. The highest increase percentage of extrusion energy was found while increasing billet lengths (BL) from 3.00 mm to 4.00 mm. The lower bearing length (LB) values offered lower consumed energy. The consumed extrusion energy linearly increased with COF. The die shift (DS) did not affect the extrusion energy, but the final part geometry (curved pins). The results and analysis from this study could be used to potential energy savings and overall production costs of the micro-extrusion process.

Author(s):  
Sedthawatt Sucharitwatskul ◽  
Numpon Mahayotsanun ◽  
Sujin Bureerat ◽  
Kuniaki Dohda

Abstract This paper investigated key factors influencing energy consumption in the micro-extrusion process. The considered factors were: extrusion ratio (ER), die angle (α), billet length (BL), bearing length (LB), coefficient of friction (COF), and die shift (DS). The finite element simulation was carried out to determine the extrusion energy required to complete one extrusion cycle. The simulation results showed that the increased values of all the considered factors (except the die shift) led to increased extrusion energy. The results also provided percentages of energy variation in steps, which helped evaluate the energy savings with regards to the crucial other production considerations. The percentage increase in energy consumption in the lower ER values was considered higher than those of, the higher ER values. Increasing die angle (α) from 60° to 90° barely affected the consumed energy. The highest increase percentage of extrusion energy was found while increasing billet lengths (BL) from 3.00 mm to 4.00 mm. The lower bearing length (LB) values offered lower consumed energy. The consumed extrusion energy linearly increased with COF. The die shift (DS) did not affect the extrusion energy, but the final part geometry (curved pins). The results and analysis from this study could be used to potential energy savings and overall production costs of the micro-extrusion process.


2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


2019 ◽  
Vol 118 (5) ◽  
pp. 122-131
Author(s):  
S. Thowseaf ◽  
M. Ayisha Millath ◽  
K. Malik Ali

Tax is an important source of income for the country. It is through tax; country strengthens its defense system, infrastructure, and government. Hence, tax system plays a predominant role in developing country’s economy. The complication in taxation system and liberty for taxpayers are key factors generating loopholes for corruption. GST is superior taxation system over VAT but, if neither properly implemented nor scrutinized according to the economy, it is people residing get affected.  GST taxation system is capable of increasing legal transaction, reducing corruption and complexity that exists in current taxation. India is 166th country to adopt GST and GST taxation slab in India is 0%, 5%, 12%, 18% and 28%.  Although average Tax levied is 14.8750% in India, it is 28% tax that is levied for most of the commodities, which are directly or indirectly used in everyday life of common individuals. Despite, GST being favorable to distributor in-terms of profit and government to attain tax by increasing legal transaction through invoice. It is noted that for the same percentage of taxation, the amount does not vary for VAT and GST. The tax slab decreased for 71 commodities and no change in 21 commodities; there has been an increase in tax slab for 60 commodities. 26% taxation was levied for most commodities considered was currently levied by 28% taxation which is greater than before. It was found that average tax percentage reduced was calculated to be 6.07143. The average tax percentage increase was calculated to be 4.7833 percentage for the considered commodities. The overall tax average tax percentage is estimated to be 14.8750% which does not have a significant difference concerning tax levied before GST, which was calculated to be 15.7829% for considered commodities. Therefore, the consumer purchasing power and overall living standard of the individual in India will remain almost same.


2012 ◽  
Vol 7 (4) ◽  
Author(s):  
A. Lazić ◽  
V. Larsson ◽  
Å. Nordenborg

The objective of this work is to decrease energy consumption of the aeration system at a mid-size conventional wastewater treatment plant in the south of Sweden where aeration consumes 44% of the total energy consumption of the plant. By designing an energy optimised aeration system (with aeration grids, blowers, controlling valves) and then operating it with a new aeration control system (dissolved oxygen cascade control and most open valve logic) one can save energy. The concept has been tested in full scale by comparing two treatment lines: a reference line (consisting of old fine bubble tube diffusers, old lobe blowers, simple DO control) with a test line (consisting of new Sanitaire Silver Series Low Pressure fine bubble diffusers, a new screw blower and the Flygt aeration control system). Energy savings with the new aeration system measured as Aeration Efficiency was 65%. Furthermore, 13% of the total energy consumption of the whole plant, or 21 000 €/year, could be saved when the tested line was operated with the new aeration system.


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Batyrbek Alimkhanuly ◽  
Joon Sohn ◽  
Ik-Joon Chang ◽  
Seunghyun Lee

AbstractRecent studies on neural network quantization have demonstrated a beneficial compromise between accuracy, computation rate, and architecture size. Implementing a 3D Vertical RRAM (VRRAM) array accompanied by device scaling may further improve such networks’ density and energy consumption. Individual device design, optimized interconnects, and careful material selection are key factors determining the overall computation performance. In this work, the impact of replacing conventional devices with microfabricated, graphene-based VRRAM is investigated for circuit and algorithmic levels. By exploiting a sub-nm thin 2D material, the VRRAM array demonstrates an improved read/write margins and read inaccuracy level for the weighted-sum procedure. Moreover, energy consumption is significantly reduced in array programming operations. Finally, an XNOR logic-inspired architecture designed to integrate 1-bit ternary precision synaptic weights into graphene-based VRRAM is introduced. Simulations on VRRAM with metal and graphene word-planes demonstrate 83.5 and 94.1% recognition accuracy, respectively, denoting the importance of material innovation in neuromorphic computing.


2021 ◽  
Vol 13 (6) ◽  
pp. 3470
Author(s):  
Przemysław Kowalik ◽  
Magdalena Rzemieniak

The problem of scheduling pumps is widely discussed in the literature in the context of improving energy efficiency, production costs, emissions, and reliability. In some studies, the authors analyze the available case studies and compare the results; others present their own computational methods. In the paper, a problem of pump scheduling in regular everyday operations of a water supply operator is considered. The issues of water production optimization and energy savings are part of the topic of sustainable development. The objective of the article is the minimization of the cost of electric power used by the pumps supplying water. It is achieved thanks to the variability of both the demand for water and the price of electric power during the day combined with the possibility of storing water. The formulation of an existing electric power cost optimization problem as a binary linear programming problem was improved. An essential extension of the above mathematical model, which enables more flexible management of the pump system, was also proposed. An example containing real-world input data was successfully solved using Microsoft Excel with a free OpenSolver add-in.


2021 ◽  
Vol 11 (6) ◽  
pp. 2735
Author(s):  
Ernesto Olvera-Gonzalez ◽  
Martín Montes Rivera ◽  
Nivia Escalante-Garcia ◽  
Eduardo Flores-Gallegos

Artificial lighting is a key factor in Closed Production Plant Systems (CPPS). A significant light-emitting diode (LED) technology attribute is the emission of different wavelengths, called light recipes. Light recipes are typically configured in continuous mode, but can also be configured in pulsed mode to save energy. We propose two nonlinear models, i.e., genetic programing (GP) and feedforward artificial neural networks (FNNs) to predict energy consumption in CPPS. The generated models use the following input variables: intensity, red light component, blue light component, green light component, and white light component; and the following operation modes: continuous and pulsed light including pulsed frequency, and duty cycle as well energy consumption as output. A Spearman's correlation was applied to generate a model with only representative inputs. Two datasets were applied. The first (Test 1), with 5700 samples with similar input ranges, was used to train and evaluate, while the second (Test 2), included 160 total datapoints in different input ranges. The metrics that allowed a quantitative evaluation of the model's performance were MAPE, MSE, MAE, and SEE. Our implemented models achieved an accuracy of 96.1% for the GP model and 98.99% for the FNNs model. The models used in this proposal can be applied or programmed as part of the monitoring system for CPPS which prioritize energy efficiency. The nonlinear models provide a further analysis for energy savings due to the light recipe and operation light mode, i.e., pulsed and continuous on artificial LED lighting systems.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3876
Author(s):  
Sameh Monna ◽  
Adel Juaidi ◽  
Ramez Abdallah ◽  
Aiman Albatayneh ◽  
Patrick Dutournie ◽  
...  

Since buildings are one of the major contributors to global warming, efforts should be intensified to make them more energy-efficient, particularly existing buildings. This research intends to analyze the energy savings from a suggested retrofitting program using energy simulation for typical existing residential buildings. For the assessment of the energy retrofitting program using computer simulation, the most commonly utilized residential building types were selected. The energy consumption of those selected residential buildings was assessed, and a baseline for evaluating energy retrofitting was established. Three levels of retrofitting programs were implemented. These levels were ordered by cost, with the first level being the least costly and the third level is the most expensive. The simulation models were created for two different types of buildings in three different climatic zones in Palestine. The findings suggest that water heating, space heating, space cooling, and electric lighting are the highest energy consumers in ordinary houses. Level one measures resulted in a 19–24 percent decrease in energy consumption due to reduced heating and cooling loads. The use of a combination of levels one and two resulted in a decrease of energy consumption for heating, cooling, and lighting by 50–57%. The use of the three levels resulted in a decrease of 71–80% in total energy usage for heating, cooling, lighting, water heating, and air conditioning.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3912
Author(s):  
Wassim Salameh ◽  
Jalal Faraj ◽  
Elias Harika ◽  
Rabih Murr ◽  
Mahmoud Khaled

In the context of a world energy crisis, the only solution to control the situation is in the management of energy. One of the most important management keys is the optimization of electrical components. This article presents a complete numerical and experimental study aiming for the optimization of electrical water heaters for household use. The optimization conceives the minimization of energy consumption simultaneously with the minimization of time to heat water. Firstly, a thermal model well adapted for the case of heaters is constructed and validated experimentally and then a parametric study is conducted covering all the input power, the volume and the external area of the heater. Results are promising, showing significant energy savings are possible with an optimum setting of these parameters, thus presenting a firm tool for the optimization of heaters.


2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC