Thermal Performance Analysis and Heat Transfer Enhancement Study in an Antminer Mining Machine

Author(s):  
Wen-Xiao Chu ◽  
Yao-Wen Chang ◽  
Yi-Yu Hu ◽  
Chi-Chuan Wang

Abstract In this paper, the thermal performance of an AntMiner mining machine containing 189 chips on three printed circuit board (PCBs) is experimentally studied. The numerical method is applied to analyze the local airflow and thermal distribution alongside the flow direction and shows a good agreement with the experimental results. Some hot-spot regions are identified where chips might suffer under high-temperature operating condition. Meanwhile, the highly compact arrangement may result in pronounced bypass and jeopardize the thermal performance of the mining machine rapidly; thereby, the airflow management strategy for such confined compartment is implemented. The result shows that the flowrate distribution can be notably improved. Although the total flowrate is slightly reduced by 4.4%, the maximum chip temperature on three PCBs can be reduced by 3.2 °C, 3.5 °C, and 3.0 °C, and the corresponding improvement on thermal performance reaches 13.3%, 15.6%, and 13.0%, respectively. Furthermore, the maximum temperature of the downstream chips will be reduced by 2.5 °C when incorporating the “partial bypass” design by the removal of 12 backside heat sinks. The corresponding heat transfer performance is improved by 8.9–13.9%.

2019 ◽  
Vol 141 (5) ◽  
Author(s):  
Sangbeom Cho ◽  
Yogendra Joshi

We develop a vapor chamber integrated with a microelectronic packaging substrate and characterize its heat transfer performance. A prototype of vapor chamber integrated printed circuit board (PCB) is fabricated through successful completion of the following tasks: patterning copper micropillar wick structures on PCB, mechanical design and fabrication of condenser, device sealing, and device vacuuming and charging with working fluid. Two prototype vapor chambers with distinct micropillar array designs are fabricated, and their thermal performance tested under various heat inputs supplied from a 2 mm × 2 mm heat source. Thermal performance of the device improves with heat inputs, with the maximum performance of ∼20% over copper plated PCB with the same thickness. A three-dimensional computational fluid dynamics/heat transfer (CFD/HT) numerical model of the vapor chamber, coupled with the conduction model of the packaging substrate is developed, and the results are compared with test data.


1994 ◽  
Vol 116 (3) ◽  
pp. 198-205 ◽  
Author(s):  
C. Y. Choi ◽  
S. J. Kim ◽  
A. Ortega

The coupled conduction and forced convection transport from substrate-mounted modules in a channel is numerically investigated to identify the effects of the substrate conductivity. The results presented apply to air and two-dimensional laminar flow conditions. It was found that recirculating cells as well as streamwise conduction through the substrate play an important role in predicting convective heat transfer from the printed circuit board (PCB) and modules and in determining the temperature distributions in the PCB, modules, and fluid. The dimensionless temperature and the local Nusselt number along the interface between the fluid and the module or PCB are rather complicated, and therefore, predetermined simple boundary conditions along the solid surface may be inappropriate in many conjugate heat transfer problems. In general, the results show that the maximum temperature within heat sources can be greatly reduced by increasing the conductivity of the PCB. The effectiveness of the use of highly conductive materials for PCB, however, depends on the distance between the heat generating modules on the PCB. In addition, finite thermal resistance between the module and the PCB would serve to diminish the PCB conduction effects, thereby reducing the effectiveness of the enhancement afforded by increased conductivity.


Author(s):  
Suabsakul Gururatana ◽  
Xianchang Li

The power density of electronic devices has been increasing along with the rapid technology development. Cooling of electronic systems is therefore essential in controlling the component temperature and avoiding any hot spot. Heat sinks are commonly adopted in electronics cooling together with different technologies to enhance heat transfer process. Fin-based heat sinks are commonly designed so that coolants (gas or liquid) are forced to pass through the narrow straight channel. A driving fan is then needed to overcome the viscous pressure loss and maintain the coolant flow. As part of effort to improve the heat sink performance, this study simulated the details of the flow and temperature fields of heat sinks with interrupted and staggered elliptic fins cooled by forced convection. The focus of this study lies on three scenarios: Heat transfer before the flow reaches the periodic condition in the flow direction; effect of the heat sink base surface on flow and heat transfer; and conjugate heat transfer between convection and heat conduction inside the fins. In addition, studies were also conducted on the effect of the Reynolds number. The results of this paper can help design heat sinks for electronics cooling by employing the new concept of interrupted and staggered fins.


Author(s):  
William Ng ◽  
Kevin Weaver ◽  
Zachary Gemmill ◽  
Herve Deslandes ◽  
Rudolf Schlangen

Abstract This paper demonstrates the use of a real time lock-in thermography (LIT) system to non-destructively characterize thermal events prior to the failing of an integrated circuit (IC) device. A case study using a packaged IC mounted on printed circuit board (PCB) is presented. The result validated the failing model by observing the thermal signature on the package. Subsequent analysis from the backside of the IC identified a hot spot in internal circuitry sensitive to varying value of external discrete component (inductor) on PCB.


2020 ◽  
Vol 319 ◽  
pp. 02004
Author(s):  
Muhammad Akif Rahman ◽  
Md Badrath Tamam ◽  
Md Sadman Faruque ◽  
A.K.M. Monjur Morshed

In this paper a numerical analysis of three-dimensional laminar flow through rectangular channel heat sinks of different geometric configuration is presented and a comparison of thermal performance among the heat sinks is discussed. Liquid water was used as coolant in the aluminum made heat sink with a glass cover above it. The aspect ratio (section height to width) of rectangular channels of the mini-channel heat sink was 0.33. A heat flux of 20 W/cm2 was continuously applied at the bottom of the channel with different inlet velocity for Reynold’s number ranging from 150 to 1044. Interconnectors and obstacles at different positions and numbers inside the channel were introduced in order to enhance the thermal performance. These modifications cause secondary flow between the parallel channels and the obstacles disrupt the boundary layer formation of the flow inside the channel which leads to the increase in heat transfer rate. Finally, Nusselt number, overall thermal resistance and maximum temperature of the heat sink were calculated to compare the performances of the modified heat sinks with the conventional mini channel heat sink and it was observed that the heat sink with both interconnectors and obstacles enhanced the thermal performance more significantly than other configurations. A maximum of 36% increase in Nusselt number was observed (for Re =1044).


2005 ◽  
Vol 128 (4) ◽  
pp. 412-418 ◽  
Author(s):  
Zhipeng Duan ◽  
Y. S. Muzychka

Impingement cooling of plate fin heat sinks is examined. Experimental measurements of thermal performance were performed with four heat sinks of various impingement inlet widths, fin spacings, fin heights, and airflow velocities. The percent uncertainty in the measured thermal resistance was a maximum of 2.6% in the validation tests. Using a simple thermal resistance model based on developing laminar flow in rectangular channels, the actual mean heat transfer coefficients are obtained in order to develop a simple heat transfer model for the impingement plate fin heat sink system. The experimental results are combined into a dimensionless correlation for channel average Nusselt number Nu∼f(L*,Pr). We use a dimensionless thermal developing flow length, L*=(L∕2)∕(DhRePr), as the independent parameter. Results show that Nu∼1∕L*, similar to developing flow in parallel channels. The heat transfer model covers the practical operating range of most heat sinks, 0.01<L*<0.18. The accuracy of the heat transfer model was found to be within 11% of the experimental data taken on four heat sinks and other experimental data from the published literature at channel Reynolds numbers less than 1200. The proposed heat transfer model may be used to predict the thermal performance of impingement air cooled plate fin heat sinks for design purposes.


Author(s):  
Ali Radwan ◽  
Meshack Hawi ◽  
Mahmoud Ahmed

In this study, an efficient cooling technique for concentrator photovoltaic (CPV) cells is proposed to enhance the system electrical efficiency and extend its lifetime. To do this, a comprehensive three-dimensional conjugate heat transfer model of CPV cells layers coupled with the heat transfer and fluid flow model inside jet impingement heat sink is developed. Four different jet impingement designs are compared. The investigated designs are (A) central inlet jet, (B) Hypotenuse inlet jet, (C) staggered inlet jet, and (D) conventional jet impingement design with side drainage. The effect of coolant flowrate on the CPV/T system performance is investigated. The model is numerically simulated and validated using the available experiments. The performance of CPV system is investigated at solar concentration ratios of 20 and coolant flowrate up to 6000g/min. It is found that increasing the flowrate from 60 g/min to 600 g/min decrease the maximum cell temperature by 31°C for the configuration D while increasing the flowrate from 600 g/min to 6000 g/min reduce the cell temperature by 20.2°C. It is also concluded that at a higher flowrate of 6000g/min, all the investigated configurations relatively achieve better temperature uniformity with maximum temperature differences of 0.9 °C, 2.1 °C, 3.6 °C, and 3.9 °C for configurations A, B, C, and D respectively.


2021 ◽  
Vol 1163 ◽  
pp. 73-88
Author(s):  
Md Tanbir Sarowar

Microchannel heat sink plays a vital role in removing a considerable amount of heat flux from a small surface area from different electronic devices. In recent times, the rapid development of electronic devices requires the improvement of these heat sinks to a greater extent. In this aspect, the selection of appropriate substrate materials of the heat sinks is of vital importance. In this paper, three boron-based ultra-high temperature ceramic materials (ZrB2, TiB2, and HfB2) are compared as a substrate material for the microchannel heat sink using a numerical approach. The fluid flow and heat transfer are analyzed using the finite volume method. The results showed that the maximum temperature of the heat source didn’t exceed 355K at 3.6MWm-2 for any material. The results also indicated HfB2 and TiB2 to be more useful as a substrate material than ZrB2. By applying 3.6 MWm-2 heat flux at the source, the maximum obtained surface heat transfer coefficient was 175.2 KWm-2K-1 in a heat sink having substrate material HfB2.


Volume 1 ◽  
2004 ◽  
Author(s):  
Arnout Willockx ◽  
Gilbert De Mey ◽  
Michel De Paepe ◽  
Boguslaw Wiecek ◽  
Mariusz Felczak ◽  
...  

The objective is to separate natural convection and radiation experimentally. Therefore a heat source is placed inside a closed cavity and the acceleration inside the cavity can be changed. A centrifuge is used to change the acceleration. A flat resistor etched on a printed circuit board of 10mm × 48mm, is placed in a hermetically sealed cylinder, which hangs under the arm of the centrifuge. The resistor is powered by a battery, dissipates 0,35W and has a surface temperature of 60°C at 1g. Natural convection is maintained inside the cylinder. Conduction is reduced to a negligible amount by construction of the experiment, thus convection and radiation are the main modes of heat transfer. The rotational speed of the centrifuge determines the centrifugal force in the cylinder. When the centripetal force increases, the temperature of the resistor decreases due to the increase of natural convection. The amount of radiation and total heat transfer can be determined from the experiment, so the amount of natural convection can also be determined. The experimental results are compared with the governing equations to validate the experiment. The reproducibility of the experiment is also checked.


Author(s):  
Abas Abdoli ◽  
George S. Dulikravich

Multi-floor networks of straight-through liquid cooled microchannels have been investigated by performing conjugate heat transfer in a silicon substrate of size 15×15×1 mm. Two-floor and three-floor cooling configurations were analyzed with different numbers of microchannels on each floor, different diameters of the channels, and different clustering among the floors. Thickness of substrate was calculated based on number of floors, diameter of floors and vertical clustering. Direction of microchannels on each floor changes by 90 degrees from the previous floor. Direction of flow in each microchannel is opposite of the flow direction in its neighbor channels. Conjugate heat transfer analysis was performed by developing a software package which uses quasi-1D thermo-fluid analysis and a 3D steady heat conduction analysis. These two solvers are coupled through their common boundaries representing surfaces of the cooling microchannels. Using quasi-1D solver significantly decreases overall computing time and its results are in good agreement with 3D Navier-Stokes equations solver for these types of application. Multi-objective optimization with modeFRONTIER software was performed using response surface approximations and genetic algorithm. Maximizing total amount of heat removed, minimizing coolant pressure drop, minimizing maximum temperature on the hot surface, and minimizing non-uniformity of temperature on the hot surface were four simultaneous objectives of the optimization. Pareto-optimal solutions demonstrate that thermal loads of 800 W cm−2 can be effectively managed with such multi-floor microchannel cooling networks. Two-floor microchannel configuration was also simulated with 1,000 W cm−2 uniform thermal load and shown to be feasible.


Sign in / Sign up

Export Citation Format

Share Document