scholarly journals Observer-Based Deconvolution of Deterministic Input in Coprime Multichannel Systems With Its Application to Noninvasive Central Blood Pressure Monitoring

2020 ◽  
Vol 142 (9) ◽  
Author(s):  
Zahra Ghasemi ◽  
Woongsun Jeon ◽  
Chang-Sei Kim ◽  
Anuj Gupta ◽  
Rajesh Rajamani ◽  
...  

Abstract Estimating central aortic blood pressure (BP) is important for cardiovascular (CV) health and risk prediction purposes. CV system is a multichannel dynamical system that yields multiple BPs at various body sites in response to central aortic BP. This paper concerns the development and analysis of an observer-based approach to deconvolution of unknown input in a class of coprime multichannel systems applicable to noninvasive estimation of central aortic BP. A multichannel system yields multiple outputs in response to a common input. Hence, the relationship between any pair of two outputs constitutes a hypothetical input–output system with unknown input embedded as a state. The central idea underlying our approach is to derive the unknown input by designing an observer for the hypothetical input–output system. In this paper, we developed an unknown input observer (UIO) for input deconvolution in coprime multichannel systems. We provided a universal design algorithm as well as meaningful physical insights and inherent performance limitations associated with the algorithm. The validity and potential of our approach were illustrated using a case study of estimating central aortic BP waveform from two noninvasively acquired peripheral arterial pulse waveforms. The UIO could reduce the root-mean-squared error (RMSE) associated with the central aortic BP by up to 27.5% and 28.8% against conventional inverse filtering (IF) and peripheral arterial pulse scaling techniques.

2019 ◽  
Vol 2 (3) ◽  
pp. 206-214
Author(s):  
Putri Indes Oktabriani ◽  
Fuad Ughi ◽  
Aulia Arif Iskandar

The continuous blood pressure measurement research is widely known for helpingthe development of ambulatory blood pressure monitoring where it measures blood pressureevery 15 to 30 minutes throughout the day. The cuff is a problem for the patient withAmbulatory Blood Pressure Monitor. It can make a person feel uncomfortable and must staystill when the cuff starts to inflate. It is limiting and disturbing their daily activity when thedevice is starting to measure the blood pressure. Blood pressure measurement without cuff isbeing proposed in this research, called cuff-less blood pressure measurement. It will be based onPhotoplethysmography (PPG) and Electrocardiography (ECG) signal analysis. ECG (Lead 1,Lead 2, and Lead 3) with PPG signal produced from index finger on the left hand are comparedand analyzed. Then the relation of PPG and ECG signal and the optimum location for daily usecan be obtained. The optimum location will be based on the electrode’s position that producedthe optimum ECG lead Signal to measure blood pressure. Based on the result, PPG and ECGsignal have a linear relation with Blood Pressure Measurement and Lead 1 is more stable inproducing the ECG signal. The equation from Lead 1 appeared as one of the optimum equationsfor measuring Systolic Blood Pressure (SBP) or Diastolic Blood Pressure (DBP).


2020 ◽  
pp. 30-40
Author(s):  
M. G. Melnik

Purpose. To study the dynamics of blood pressure (BP) indicators under the influence of exogenously administered melatonin (Melatonin-SZ, Severnaya Zvezda, Russia) with various manifestations of desynchronosis of circadian BP rhythms (arterial hypertension – AH, high normal blood pressure) to determine the scheme of their effective compensation. Material and methods. The study included 101 patients with desynchronosis of circadian rhythms of blood pressure – 52 patients with hypertension, constituting the first and second groups, and 49 individuals with high normal blood pressure, representing the third and fourth groups. Patients of the second and fourth groups received conservative therapy, patients of the first and third groups combined it with melatonin. All patients underwent measurements of office blood pressure, home monitoring of blood pressure (ABPM), electrocardiography, 24-hour blood pressure monitoring (ABPM). Results and discussion. In patients of the first and third groups, compared with the traditional treatment groups, by the end of the observation period, a significantly (p < 0.05) decrease in office systolic blood pressure (SBP) / diastolic blood pressure (DBP) was established: in the first group compared with the second – 1.11 / 1.13 times, in the third group compared to the fourth – 1.43 / 1.58 times; significantly more (p < 0.05) pronounced decrease in SBP / DBP during DMAD – by 1.08 / 1.17 and 1.58 / 1.62 times, respectively, Significantly (p < 0.05) more pronounced decrease in average daily, average daily and average nighttime SBP / DBP during ABPM – by 1.13 / 1.20, 1.11 / 1.20, 1.23 / 1.25 and 1.47 / 1.31, 1.42 / 1.19, 1.54 / 1.41 times, respectively; reliably (p < 0.05) more frequent registration of the dipper rhythm type SBP / DBP – 1.6 / 1.4 and 1.6 / 1.4 times, respectively. In addition, the dynamics of patients in the first and third groups showed a significant (p < 0.05) decrease in the mean daily and mean nighttime SBP / DBP variability (SBP in the first group by 27.3 and 41.3 %, respectively; DBP in the first group by 20.1 and 26.3 %, respectively; SBP in the third group by 13.5 and 25.2 %, respectively; DBP in the third group by 12.2 and 28.2 %, respectively). Conclusions. With various manifestations of desynchronosis of circadian rhythms of blood pressure (AH, high normal blood pressure), the prescription of melatonin (Melatonin-SZ, Severnaya Zvezda, Russia) at a dose of 3 mg per day 30–40 minutes before bedtime for a month against the background of non-drug therapy and antihypertensive drugs led to a significantly more effective decrease in blood pressure at its office measurement, DMAD, ABPM with an improvement in the circadian rhythm of blood pressure and normalization of blood pressure variability.


2014 ◽  
Author(s):  
Francisco Javier Vilchez-Lopez ◽  
Isabel Mateo-Gavira ◽  
Florentino Carral-San Laureano ◽  
Maria Victoria Garcia-Palacios ◽  
Jose Ortego-Rojo ◽  
...  

2020 ◽  
Vol 111 (6) ◽  
Author(s):  
Ramón C. Hermida ◽  
Artemio Mojón ◽  
José R. Fernández ◽  
Alfonso Otero ◽  
Juan J. Crespo ◽  
...  