Computational Fluid Dynamics Modeling of Gaseous Cavitation in Lubricating Vane Pumps: An Approach Based on Dimensional Analysis

2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Umberto Stuppioni ◽  
Alessio Suman ◽  
Michele Pinelli ◽  
Alessandro Blum

Abstract This paper addresses the problem of computational fluid dynamics (CFD) modeling of gaseous cavitation (GC) in lubricating positive-displacement pumps (PDPs). It is important for designers and analysts to predict the dynamic features of air release/dissolution processes which characterize this phenomenon, along with their effects on filling capability and noise-vibration-harshness behavior of the machine. The focus is on the empirical tuning of the commercial homogeneous-flow cavitation model known as dissolved gas model (DGM). Considering an automotive case study of a balanced vane pump (BVP), the effects of air modeling on numerical predictions of discharge flow/pressure ripple and volumetric efficiency have been studied. The tuning time parameters of the model have been correlated to the machine Reynolds number as part of a simplified theoretical background based on dimensional analysis. Considering experimental data at different operating conditions, the tuned model has shown a good capacity in predicting the pressure ripple and the flowrate at the discharge of the pump.

Processes ◽  
2020 ◽  
Vol 9 (1) ◽  
pp. 79
Author(s):  
Minghan Luo ◽  
Wenjie Xu ◽  
Xiaorong Kang ◽  
Keqiang Ding ◽  
Taeseop Jeong

The ultraviolet photochemical degradation process is widely recognized as a low-cost, environmentally friendly, and sustainable technology for water treatment. This study integrated computational fluid dynamics (CFD) and a photoreactive kinetic model to investigate the effects of flow characteristics on the contaminant degradation performance of a rotating annular photoreactor with a vacuum-UV (VUV)/UV process performed in continuous flow mode. The results demonstrated that the introduced fluid remained in intensive rotational movement inside the reactor for a wide range of inflow rates, and the rotational movement was enhanced with increasing influent speed within the studied velocity range. The CFD modeling results were consistent with the experimental abatement of methylene blue (MB), although the model slightly overestimated MB degradation because it did not fully account for the consumption of OH radicals from byproducts generated in the MB decomposition processes. The OH radical generation and contaminant degradation efficiency of the VUV/UV process showed strong correlation with the mixing level in a photoreactor, which confirmed the promising potential of the developed rotating annular VUV reactor in water treatment.


Author(s):  
Riccardo Da Soghe ◽  
Cosimo Bianchini ◽  
Antonio Andreini ◽  
Lorenzo Mazzei ◽  
Giovanni Riccio ◽  
...  

Combustor liner of present gas turbine engines is subjected to high thermal loads as it surrounds high temperature combustion reactants and is hence facing the related radiative load. This generally produces high thermal stress levels on the liner, strongly limiting its life expectations and making it one of the most critical components of the entire engine. The reliable prediction of such thermal loads is hence a crucial aspect to increase the flame tube life span and to ensure safe operations. The present study aims at investigating the aerothermal behavior of a GE Dry Low NOx (DLN1) class flame tube and in particular at evaluating working metal temperatures of the liner in relation to the flow and heat transfer state inside and outside the combustion chamber. Three different operating conditions have been accounted for (i.e., lean–lean partial load, premixed full load, and primary load) to determine the amount of heat transfer from the gas to the liner by means of computational fluid dynamics (CFD). The numerical predictions have been compared to experimental measurements of metal temperature showing a good agreement between CFD and experiments.


2018 ◽  
Vol 140 (9) ◽  
Author(s):  
Juan Carlos Berrio ◽  
Eduardo Pereyra ◽  
Nicolas Ratkovich

The gas–liquid cylindrical cyclone (GLCC) is a widely used alternative for gas–liquid conventional separation. Besides its maturity, the effect of some geometrical parameters over its performance is not fully understood. The main objective of this study is to use computational fluid dynamics (CFD) modeling in order to evaluate the effect of geometrical modifications in the reduction of liquid carry over (LCO) and gas carry under (GCU). Simulations for two-phase flow were carried out under zero net liquid flow, and the average liquid holdup was compared with Kanshio (Kanshio, S., 2015, “Multiphase Flow in Pipe Cyclonic Separator,” Ph.D. thesis, Cranfield University, Cranfield, UK) obtaining root-mean-square errors around 13% between CFD and experimental data. An experimental setup, in which LCO data were acquired, was built in order to validate a CFD model that includes both phases entering to the GLCC. An average discrepancy below 6% was obtained by comparing simulations with experimental data. Once the model was validated, five geometrical variables were tested with CFD. The considered variables correspond to the inlet configuration (location and inclination angle), the effect of dual inlet, and nozzle geometry (diameter and area reduction). Based on the results, the best configuration corresponds to an angle of 27 deg, inlet location 10 cm above the center, a dual inlet with 20 cm of spacing between both legs, a nozzle of 3.5 cm of diameter, and a volute inlet of 15% of pipe area. The combination of these options in the same geometry reduced LCO by 98% with respect to the original case of the experimental setup. Finally, the swirling decay was studied with CFD showing that liquid has a greater impact than the gas flowrate.


Author(s):  
L. Sun ◽  
K. Podila ◽  
Q. Chen ◽  
A. M. Bayomy ◽  
Y. F. Rao

Abstract The nuclear industry has seen an increased use of computational fluid dynamics (CFD) technology as a high-fidelity tool for design-basis and beyond-design-basis accident simulations. Among its applications, CFD modeling of fire and smoke propagation in confined zones (e.g., a main control room (MCR)) is a promising approach, since detailed experimental investigation under various accident scenarios would be difficult. Egress analysis considering human behaviors is of significant importance to an effective accident mitigation strategy, and high-fidelity analysis tools now encompass these parameters in the simulation and design of emergency evacuations. In this study, the fire and smoke propagation in a MCR is modeled using the large eddy simulations (LES) code fire dynamics simulator (FDS), along with an evacuation module, EVAC to simulate the emergency egress under an electrical cabinet fire scenario. The FDS results presented in this paper constitute the first step at Canadian Nuclear Laboratories (CNL) in advancing the CFD modeling of fire and evacuation for nuclear applications.


Author(s):  
Stefano Cordiner ◽  
Simon Pietro Lanzani ◽  
Vincenzo Mulone ◽  
Marco Chiapparini ◽  
Angelo D’Anzi ◽  
...  

An entirely numerical design procedure, based on computational fluid dynamics, is introduced to evaluate the performance of different polymer electrolyte fuel cell layouts and sets of operating conditions for assigned target parameters in terms of performance. The design procedure has been applied to a coflow design, characterized by large active area (500 cm2), moderate temperature (70°C), liquid cooling, and metal supporting. The role of heat transfer between the cell and the cooling system is analyzed to properly address the influence of operating conditions on power density and flooding via a comprehensive parametric analysis.


2005 ◽  
Vol 2 (4) ◽  
pp. 246-257 ◽  
Author(s):  
L. Ma ◽  
D. B. Ingham ◽  
M. Pourkashanian ◽  
E. Carcadea

This paper presents a review of the current situation in the computational fluid dynamics (CFD) modeling of fuel cells and highlights the significant challenges that lie ahead in the development of a comprehensive CFD model for fuel cell applications. The paper focuses on the issues concerned with solid oxide fuel cells and proton exchange membrane fuel cells because these are the two most poplar and probably the most promising types of fuel cells for both stationary and transport applications. However, the general principles presented in this paper are applicable to all types of fuel cells.


Author(s):  
Jorge Aramburu ◽  
Raúl Antón ◽  
Macarena Rodríguez-Fraile ◽  
Bruno Sangro ◽  
José Ignacio Bilbao

AbstractYttrium-90 radioembolization (RE) is a widely used transcatheter intraarterial therapy for patients with unresectable liver cancer. In the last decade, computer simulations of hepatic artery hemodynamics during RE have been performed with the aim of better understanding and improving the therapy. In this review, we introduce the concept of computational fluid dynamics (CFD) modeling with a clinical perspective and we review the CFD models used to study RE from the fluid mechanics point of view. Finally, we show what CFD simulations have taught us about the hemodynamics during RE, the current capabilities of CFD simulations of RE, and we suggest some future perspectives.


Author(s):  
Taleb Zarei ◽  
Reza Hamidi Jahromi ◽  
Arash Mohammadi Karachi

In this article, a novel tray humidifier column for humidification dehumidification desalination was proposed. The performance of the humidifier column has been investigated with experimental and computational fluid dynamics simulations. The hydrodynamics and heat transfer characteristics of this tray humidifier has been studied. A stainless steel sieve tray with a rectangular cross section with a dimension of 20 × 50 cm was used in the experimental study. In computational fluid dynamics modeling, a transient three-dimensional model has been developed based on the volume of fluid framework by using standard k-epsilon model. The effect of air and seawater flow rate and inlet seawater temperature on the exit air temperature has been investigated. The results show that the humidifier effectiveness of the tray humidifier column varies between 0.67 and 0.87 depending on operating conditions. Then, tray column can be used in humidification dehumidification desalination systems with advantages such as compact equipment, low-pressure drop, and handling solids or other sources of fouling.


Membranes ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 123
Author(s):  
Alberto Fernández ◽  
Cintia Casado ◽  
David Alique ◽  
José Antonio Calles ◽  
Javier Marugán

This work focused on the computational fluid dynamics (CFD) modeling of H2/N2 separation in a membrane permeator module containing a supported dense Pd-based membrane that was prepared using electroless pore-plating (ELP-PP). An easy-to-implement model was developed based on a source–sink pair formulation of the species transport and continuity equations. The model also included the Darcy–Forcheimer formulation for modeling the porous stainless steel (PSS) membrane support and Sieverts’ law for computing the H2 permeation flow through the dense palladium film. Two different reactor configurations were studied, which involved varying the hydrogen flow permeation direction (in–out or out–in). A wide range of experimental data was simulated by considering the impact of the operating conditions on the H2 separation, such as the feed pressure and the H2 concentration in the inlet stream. Simulations of the membrane permeator device showed an excellent agreement between the predicted and experimental data (measured as permeate and retentate flows and H2 separation). Molar fraction profiles inside the permeator device for both configurations showed that concentration polarization near the membrane surface was not a limit for the hydrogen permeation but could be useful information for membrane reactor design, as it showed the optimal length of the reactor.


Sign in / Sign up

Export Citation Format

Share Document