Anisotropic Diffusivity Tensor in Articular Cartilage: Effective Medium Approach

2020 ◽  
Vol 142 (8) ◽  
Author(s):  
Kotaybah Hashlamoun ◽  
Salvatore Federico

Abstract Due to the avascular nature of articular cartilage, molecular transport occurs via interstitial fluid flow as well as via diffusion. Diffusion in cartilage has been studied experimentally, but no mathematical models have been developed to interpret the experimental results and the observed isotropy or anisotropy in the different cartilage zones. Here, we propose a model for the determination of the diffusivity tensor of uncharged macromolecules in articular cartilage, accounting for the inhomogeneity and anisotropy arising from fiber arrangement, volumetric fraction, and radius. We study a representative element of volume (REV) comprising a fiber surrounded by fluid-saturated proteoglycan matrix. The REV permeability tensor is evaluated using a previously developed model, while the REV diffusivity tensor is obtained by incorporating the hydrodynamic effect and the steric effect of the fiber-reinforced matrix. Both effects are represented by anisotropic second-order tensors. The overall diffusivity tensor is obtained as the averaging integral of the REV diffusivity, weighted by the probability distribution of fiber orientation. The model's predictions of the trend of the magnitude of the diffusivity of spheroidal macromolecules as a function of molecular radius agree with published experimental results. For large linear macromolecules, the model underestimates the diffusivity magnitude (i.e., the equivalent isotropic diffusivity). The model correctly predicts the anisotropic behavior for linear macromolecules, although it underestimates the numerical value of the diffusivity anisotropy ratio of large linear macromolecules in the superficial zone, and overestimates it in the deep zone. In summary, this model constitutes a first step toward understanding the relation between diffusivity and permeability in articular cartilage.

2020 ◽  
Vol 835 ◽  
pp. 229-242
Author(s):  
Oboso P. Bernard ◽  
Nagih M. Shaalan ◽  
Mohab Hossam ◽  
Mohsen A. Hassan

Accurate determination of piezoelectric properties such as piezoelectric charge coefficients (d33) is an essential step in the design process of sensors and actuators using piezoelectric effect. In this study, a cost-effective and accurate method based on dynamic loading technique was proposed to determine the piezoelectric charge coefficient d33. Finite element analysis (FEA) model was developed in order to estimate d33 and validate the obtained values with experimental results. The experiment was conducted on a piezoelectric disc with a known d33 value. The effect of measuring boundary conditions, substrate material properties and specimen geometry on measured d33 value were conducted. The experimental results reveal that the determined d33 coefficient by this technique is accurate as it falls within the manufactures tolerance specifications of PZT-5A piezoelectric film d33. Further, obtained simulation results on fibre reinforced and particle reinforced piezoelectric composite were found to be similar to those that have been obtained using more advanced techniques. FE-results showed that the measured d33 coefficients depend on measuring boundary condition, piezoelectric film thickness, and substrate material properties. This method was proved to be suitable for determination of d33 coefficient effectively for piezoelectric samples of any arbitrary geometry without compromising on the accuracy of measured d33.


2018 ◽  
Vol 233 ◽  
pp. 00025
Author(s):  
P.V. Polydoropoulou ◽  
K.I. Tserpes ◽  
Sp.G. Pantelakis ◽  
Ch.V. Katsiropoulos

In this work a multi-scale model simulating the effect of the dispersion, the waviness as well as the agglomerations of MWCNTs on the Young’s modulus of a polymer enhanced with 0.4% MWCNTs (v/v) has been developed. Representative Unit Cells (RUCs) have been employed for the determination of the homogenized elastic properties of the MWCNT/polymer. The elastic properties computed by the RUCs were assigned to the Finite Element (FE) model of a tension specimen which was used to predict the Young’s modulus of the enhanced material. Furthermore, a comparison with experimental results obtained by tensile testing according to ASTM 638 has been made. The results show a remarkable decrease of the Young’s modulus for the polymer enhanced with aligned MWCNTs due to the increase of the CNT agglomerations. On the other hand, slight differences on the Young’s modulus have been observed for the material enhanced with randomly-oriented MWCNTs by the increase of the MWCNTs agglomerations, which might be attributed to the low concentration of the MWCNTs into the polymer. Moreover, the increase of the MWCNTs waviness led to a significant decrease of the Young’s modulus of the polymer enhanced with aligned MWCNTs. The experimental results in terms of the Young’s modulus are predicted well by assuming a random dispersion of MWCNTs into the polymer.


1993 ◽  
Vol 16 (2) ◽  
pp. 63-70 ◽  
Author(s):  
N.A. Hoenich ◽  
P.T. Smirthwaite ◽  
C. Woffindin ◽  
P. Lancaster ◽  
T.H. Frost ◽  
...  

Recirculation is an important factor in single needle dialysis and, if high, can compromise treatment efficiency. To provide information regarding recirculation characteristics of access devices used in single needle dialysis, we have developed a new technique to characterise recirculation and have used this to measure the recirculation of a Terumo 15G fistula needle and a VasCath SC2300 single lumen catheter. The experimentally obtained results agreed well with those established clinically (8.5 ± 2.4% and 18.4 ± 3.4%). The experimental results have also demonstrated a dependence on access type, pump speeds and fistula flow rate. A comparison of experimental data with theoretical predictions showed that the latter exceeded those measured with the largest contribution being due to the experimental fistula.


2002 ◽  
Vol 266 (4) ◽  
pp. 241-248 ◽  
Author(s):  
Barbara L. Schumacher ◽  
Jui-Lan Su ◽  
Kathy M. Lindley ◽  
Klaus E. Kuettner ◽  
Ada A. Cole

2014 ◽  
Vol 698 ◽  
pp. 466-471
Author(s):  
Oleg V. Panchenko ◽  
Alexey M. Levchenko ◽  
Victor A. Karkhin

Specimens of various sizes are used to determine hydrogen content in deposited metals in such standards as ISO 3690, AWS A 4.3, and GOST 23338 while measuring methods are the same. It causes problems in comparison of experimental results and brings up the following question: what kind of specimen size is optimal to determine hydrogen content? An optimal specimen size was estimated using a calculation method. Experimental and calculation results obtained by using specimens with estimated dimensions were compared to the results obtained by using the specimen with dimensions of 100*25*8 mm to determine hydrogen content in a deposited metal.


Sign in / Sign up

Export Citation Format

Share Document