Enhancement of Film Cooling Effectiveness Using Dean Vortices

2019 ◽  
Vol 142 (1) ◽  
Author(s):  
Pingting Chen ◽  
Lang Wang ◽  
Xueying Li ◽  
Jing Ren ◽  
Hongde Jiang ◽  
...  

Abstract Film cooling technology is widely used in gas turbines. With the additive manufacturing anticipated in the future, there will be more freedom in film cooling hole design. Exploiting this freedom, the present authors tried using curved holes to generate Dean vortices within the delivery line. These vortices have opposite direction of rotation to the vorticity of the kidney vortices and, thus, there is interaction between these vortices in the mixing region. It is shown that as a result of the inclusion of Dean vortices, the curved hole delivery leads to enhanced film cooling effectiveness. Numerical results, including film cooling effectiveness values, tracking of vortices in the flow field, heat transfer coefficients, and net heat flux reduction (NHFR), are compared between the curved hole, round hole, and a laidback, fan-shaped hole with blowing ratios, M, of 0.5, 1.0, 1.5, 2.0, and 2.5. The comparison shows that film cooling effectiveness values with the curved hole are higher than those with cylindrical film cooling holes at every blowing ratio studied. The curved hole has lower film cooling effectiveness values than the laidback, fan-shaped holes when M = 0.5 and 1.0, but shows advantages when the blowing ratio is higher than 1.0. There is heat transfer enhancement for the curved hole case due to a higher kinetic energy transferred to the near-wall region, however. Nevertheless, the curved hole still displays a higher NHFR when the blowing ratio is high.

Author(s):  
Pingting Chen ◽  
Lang Wang ◽  
Xueying Li ◽  
Jing Ren ◽  
Hongde Jiang ◽  
...  

Abstract Film cooling technology is widely used in gas turbines. Improvement of gas turbine thermal efficiency, specific power and specific thrust can be achieved by reducing the use of cooling air by improvements on film cooling technology. Experimental and numerical efforts have demonstrated that cooling effectiveness is reduced when kidney vortices created as the emerging film cooling jet flow interacts with the passage flow resulting in coolant lift-off and mixing. With higher blowing ratios, M, these kidney vortices become stronger and effectiveness worsens. Different technologies have been developed to enhance film cooling effectiveness by manipulating the kidney vortices. Some reduce local blowing ratios and local injection angles with expanded hole exits, called shaped holes. Others are employing hole geometries in an attempt to establish anti-kidney vortices in the flow field to weaken the effects of kidney vortices. Most of these film cooling technologies focus on methods that are within the present limits of manufacturing technology. However, with the additive manufacturing anticipated in the future, there will be more freedom in film cooling hole design. Exploiting this freedom, the present authors tried using curved holes to generate Dean vortices within the delivery line. These vortices have opposite direction of rotation to the vorticity of the kidney vortices and, thus, there is interaction between these vortices in the mixing region. It is shown that as a result of the inclusion of Dean vortices, the curved hole delivery leads to enhanced film cooling effectiveness. Numerical results, including film cooling effectiveness values, tracking of vortices in the flow field, heat transfer coefficients, and net heat flux reduction are compared between the curved hole (CH), round hole (RH) and a laidback, fan-shaped hole (SH) with blowing ratios, M, of 0.5, 1.0, 1.5, 2.0 and 2.5. The laidback, fan-shaped hole represents the state of the art in film cooling hole design. Another curved hole (RCH) with the opposite (to the CH hole) curvature of delivery line is checked for comparison, with M = 1.5. The comparison shows that film cooling effectiveness values with the CH curved hole are higher than those with cylindrical film cooling holes at every blowing ratio studied. The curved hole has lower film cooling effectiveness values than the laidback, fan-shaped holes when M = 0.5 and 1.0, but shows advantages when the blowing ratio is higher than 1.0. With the interaction between Dean vortices and kidney vortices when using curved holes, a large amount of coolant re-attaches to the wall after moving streamwise for some distance, providing improved downstream film cooling performance. There is heat transfer enhancement for the curved hole case due to a higher kinetic energy transferred to the near-wall region, however. Nevertheless, the curved hole still displays a higher net heat flux reduction (NHFR) when the blowing ratio is high.


Author(s):  
M. Ghorab ◽  
S. I. Kim ◽  
I. Hassan

Cooling techniques play a key role in improving efficiency and power output of modern gas turbines. The conjugate technique of film and impingement cooling schemes is considered in this study. The Multi-Stage Cooling Scheme (MSCS) involves coolant passing from inside to outside turbine blade through two stages. The first stage; the coolant passes through first hole to internal gap where the impinging jet cools the external layer of the blade. Finally, the coolant passes through the internal gap to the second hole which has specific designed geometry for external film cooling. The effect of design parameters, such as, offset distance between two-stage holes, gap height, and inclination angle of the first hole, on upstream conjugate heat transfer rate and downstream film cooling effectiveness performance are investigated computationally. An Inconel 617 alloy with variable properties is selected for the solid material. The conjugate heat transfer and film cooling characteristics of MSCS are analyzed across blowing ratios of Br = 1 and 2 for density ratio, 2. This study presents upstream wall temperature distributions due to conjugate heat transfer for different gap design parameters. The maximum film cooling effectiveness with upstream conjugate heat transfer is less than adiabatic film cooling effectiveness by 24–34%. However, the full coverage of cooling effectiveness in spanwise direction can be obtained using internal cooling with conjugate heat transfer, whereas adiabatic film cooling effectiveness has narrow distribution.


2003 ◽  
Vol 125 (4) ◽  
pp. 648-657 ◽  
Author(s):  
Jae Su Kwak ◽  
Je-Chin Han

Experimental investigations were performed to measure the detailed heat transfer coefficients and film cooling effectiveness on the squealer tip of a gas turbine blade in a five-bladed linear cascade. The blade was a two-dimensional model of a first stage gas turbine rotor blade with a profile of the GE-E3 aircraft gas turbine engine rotor blade. The test blade had a squealer (recessed) tip with a 4.22% recess. The blade model was equipped with a single row of film cooling holes on the pressure side near the tip region and the tip surface along the camber line. Hue detection based transient liquid crystals technique was used to measure heat transfer coefficients and film cooling effectiveness. All measurements were done for the three tip gap clearances of 1.0%, 1.5%, and 2.5% of blade span at the two blowing ratios of 1.0 and 2.0. The Reynolds number based on cascade exit velocity and axial chord length was 1.1×106 and the total turning angle of the blade was 97.9 deg. The overall pressure ratio was 1.2 and the inlet and exit Mach numbers were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. Results showed that the overall heat transfer coefficients increased with increasing tip gap clearance, but decreased with increasing blowing ratio. However, the overall film cooling effectiveness increased with increasing blowing ratio. Results also showed that the overall film cooling effectiveness increased but heat transfer coefficients decreased for the squealer tip when compared to the plane tip at the same tip gap clearance and blowing ratio conditions.


Author(s):  
Bo-lun Zhang ◽  
Li Zhang ◽  
Hui-ren Zhu ◽  
Jian-sheng Wei ◽  
Zhong-yi Fu

Film cooling performance of the double-wave trench was numerically studied to improve the film cooling characteristics. Double-wave trench was formed by changing the leading edge and trailing edge of transverse trench into cosine wave. The film cooling characteristics of transverse trench and double-wave trench were numerically studied using Reynolds Averaged Navier Stokes (RANS) simulations with realizable k-ε turbulence model and enhanced wall treatment. The film cooling effectiveness and heat transfer coefficient of double-wave trench at different trench width (W = 0.8D, 1.4D, 2.1D) conditions are investigated, and the distribution of temperature field and flow field were analyzed. The results show that double-wave trench effectively improves the film cooling effectiveness and the uniformity of jet at the downstream wall of the trench. The span-wise averaged film cooling effectiveness of the double-wave trench model increases 20–63% comparing with that of the transverse trench at high blowing ratio. The anti-counter-rotating vortices which can press the film on near-wall are formed at the downstream wall of the double-wave trench. With the double-wave trench width decreasing, the film cooling effectiveness gradually reduces at the hole center-line region of the downstream trench. With the increase of the blowing ratio, the span-wise averaged heat transfer coefficient increases. The span-wise averaged heat transfer coefficient of the double-wave trench with 0.8D and 2.1D trench width is higher than that of the double-wave trench with 1.4D trench width at the high blowing ratio conditions.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Jian-xia Luo

To investigate the effects of the inclined ribs on internal flow structure in film hole and the film cooling performance on outer surface, experimental and numerical studies are conducted on the effects of rib orientation angle on film cooling of compound cylindrical holes. Three coolant channel cases, including two ribbed cross-flow channels (135° and 45° angled ribs) and the plenum case, are studied under three blowing ratios (0.5, 1.0 and 2.0). 2D contours of film cooling effectiveness as well as heat transfer coefficient were measured by transient liquid crystal measurement technique (TLC). The steady RANS simulations with realizable k-ε turbulence model and enhanced wall treatment were performed. The results show that the spanwise width of film coverage is greatly influenced by the rib orientation angle. The spanwise width of the 45° rib case is obviously larger than that of the 135° rib case under lower blowing ratios. When the blowing ratio is 1.0, the area-averaged cooling effectiveness of the 135° rib case and the 45° rib case are higher than that of the plenum case by 38% and 107%, respectively. With the increase of blowing ratio, the film coverage difference between different rib orientation cases becomes smaller. The 45° rib case also produces higher heat transfer coefficient, which is higher than the 135° rib case by 3.4–8.7% within the studied blowing ratio range. Furthermore, the discharge coefficient of the 45° rib case is the lowest among the three cases. The helical motion of coolant flow is observed in the hole of 45° rib case. The jet divides into two parts after being blown out of the hole due to this motion, which induces strong velocity separation and loss. For the 135° rib case, the vortex in the upper half region of the secondary-flow channel rotates in the same direction with the hole inclination direction, which leads to the straight streamlines and thus results in lower loss and higher discharge coefficient.


Author(s):  
Sadam Hussain ◽  
Xin Yan

Abstract Film cooling is one of the most critical technologies in modern gas turbine engine to protect the high temperature components from erosion. It allows gas turbines to operate above the thermal limits of blade materials by providing the protective cooling film layer on outer surfaces of blade against hot gases. To get a higher film cooling effect on plain surface, current study proposes a novel strategy with the implementation of hole-pair into ramp. To gain the film cooling effectiveness on the plain surface, RANS equations combined with k-ω turbulence model were solved with the commercial CFD solver ANSYS CFX11.0. In the numerical simulations, the density ratio (DR) is fixed at 1.6, and the film cooling effect on plain surface with different configurations (i.e. with only cooling hole, with only ramp, and with hole-pair in ramp) were numerically investigated at three blowing ratios M = 0.25, 0.5, and 0.75. The results show that the configuration with Hole-Pair in Ramp (HPR) upstream the cooling hole has a positive effect on film cooling enhancement on plain surface, especially along the spanwise direction. Compared with the baseline configuration, i.e. plain surface with cylindrical hole, the laterally-averaged film cooling effectiveness on plain surface with HPR is increased by 18%, while the laterally-averaged film cooling effectiveness on plain surface with only ramp is increased by 8% at M = 0.5. As the blowing ratio M increases from 0.25 to 0.75, the laterally-averaged film cooling effectiveness on plain surface with HPR is kept on increasing. At higher blowing ratio M = 0.75, film cooling effectiveness on plain surface with HPR is about 19% higher than the configuration with only ramp.


Author(s):  
Rui-dong Wang ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Qi-ling Guo ◽  
...  

Heat transfer of the counter-inclined cylindrical and laid-back holes with and without impingement on the turbine vane leading edge model are investigated in this paper. To obtain the film cooling effectiveness and heat transfer coefficient, transient temperature measurement technique on complete surface based on double thermochromic liquid crystals is used in this research. A semi-cylinder model is used to model the vane leading edge which is arranged with two rows of holes. Four test models are measured under four blowing ratios including cylindrical film holes with and without impingement tube structure, laid-back film holes with and without impingement tube structure. This is the second part of a two-part paper, the first part paper GT2018-76061 focuses on film cooling effectiveness and this study will focus on heat transfer. Contours of surface heat transfer coefficient and laterally averaged result are presented in this paper. The result shows that the heat transfer coefficient on the surface of the leading edge is enhanced with the increase of blowing ratio for same structure. The shape of the high heat transfer coefficient region gradually inclines to span-wise direction as the blowing ratio increases. Heat transfer coefficient in the region where the jet core flows through is relatively lower, while in the jet edge region the heat transfer coefficient is relatively higher. Compared with cylindrical hole, laid-back holes give higher heat transfer coefficient. Meanwhile, the introduction of impingement also makes heat transfer coefficient higher compared with cross flow air intake. It is found that the heat transfer of the combination of laid-back hole and impingement tube can be very high under large blowing ratio which should get attention in the design process.


2012 ◽  
Vol 134 (5) ◽  
Author(s):  
Akira Murata ◽  
Satomi Nishida ◽  
Hiroshi Saito ◽  
Kaoru Iwamoto ◽  
Yoji Okita ◽  
...  

Cooling at the trailing edge of a gas turbine airfoil is one of the most difficult problems because of its thin shape, high thermal load from both surfaces, hard-to-cool geometry of narrow passages, and at the same time demand for structural strength. In this study, the heat transfer coefficient and film cooling effectiveness on the pressure-side cutback surface was measured by a transient infrared thermography method. Four different cutback geometries were examined: two smooth cutback surfaces with constant-width and converging lands (base and diffuser cases) and two roughened cutback surfaces with transverse ribs and spherical dimples. The Reynolds number of the main flow defined by the mean velocity and two times the channel height was 20,000, and the blowing ratio was varied among 0.5, 1.0, 1.5, and 2.0. The experimental results clearly showed spatial variation of the heat transfer coefficient and the film cooling effectiveness on the cutback and land top surfaces. The cutback surface results clearly showed periodically enhanced heat transfer due to the periodical surface geometry of ribs and dimples. Generally, the increase of the blowing ratio increased both the heat transfer coefficient and the film cooling effectiveness. Within the present experimental range, the dimple surface was a favorable cutback-surface geometry because it gave the enhanced heat transfer without deterioration of the high film cooling effectiveness.


Author(s):  
Kyle R. Vinton ◽  
Travis B. Watson ◽  
Lesley M. Wright ◽  
Daniel C. Crites ◽  
Mark C. Morris ◽  
...  

The combined effects of a favorable, mainstream pressure gradient and coolant-to-mainstream density ratio have been investigated. Detailed film cooling effectiveness distributions have been obtained on a flat plate with either cylindrical (θ = 30°) or laidback, fan-shaped holes (θ = 30°, β = γ = 10°) using the pressure sensitive paint (PSP) technique. In a low speed wind tunnel, both non-accelerating and accelerating flows were considered while the density ratio varied from 1–4. In addition, the effect of blowing ratio was considered, with this ratio varying from 0.5 to 1.5. The film produced by the shaped hole outperformed the round hole under the presence of a favorable pressure gradient for all blowing and density ratios. At the lowest blowing ratio, in the absence of freestream acceleration, the round holes outperformed the shaped holes. However, as the blowing ratio increases, the shaped holes prevent lift-off of the coolant and offer enhanced protection. The effectiveness afforded by both the cylindrical and shaped holes, with and without freestream acceleration, increased with density ratio.


Author(s):  
Yong W. Kim ◽  
Chad Coon ◽  
Hee-Koo Moon

Pressure-side discharge is commonly employed in turbine blades and nozzle guide vanes to keep the trailing edge metal temperatures within an allowable limit while minimizing aerodynamic penalties. Despite its widespread use, film-cooling data of the discharge slot are scarce in open literature. The objectives of the present experimental study were to measure detailed local heat transfer and film-cooling effectiveness from a 10x scale trailing-edge model of an industrial gas turbine airfoil in a low speed wind tunnel. To simulate the mainstream flow acceleration in vane and blade row passages, a linear velocity gradient was imposed using an adjustable top wall. The present work employed the composite slab quasi-steady liquid crystal method that allows measurements of local heat transfer coefficients and film-cooling effectiveness from two related tests. With this technique, the heat transfer measurement can be performed in a cold wind tunnel. The coolant-to-mainstream blowing ratio was varied between 0.25 and 1.0. The slot hydraulic diameter based Reynolds number ranged from 4,760 to 19,550. The coolant-to-mainstream density ratio was fixed at 0.95. Slot discharge coefficients were also measured with mainstream acceleration. Both local heat transfer coefficients and film-cooling effectiveness displayed a strong dependency on blowing ratio and mainstream acceleration. However, the discharge coefficients showed little dependency on the mainstream acceleration.