Visualization of Two-phase Bursting Flow Effect on the Two-Phase Closed Thermosyphon

2019 ◽  
Vol 141 (10) ◽  
Author(s):  
Yeonghwan Kim ◽  
Dong Hwan Shin ◽  
Jin Sub Kim ◽  
Seung M. You ◽  
Jungho Lee

Abstract Two-phase flow inside the two-phase closed thermosyphon (TPCT) including evaporator, adiabatic and condenser sections was visually investigated in order to qualitatively analyze the complicated behaviors of both liquid film and vapor flows simultaneously. The semi-cylindrical channel which is 650 mm long was formed in the long copper block and the flat face of the channel was covered with a flat Pyrex glass for visual observation. The inner diameter of the semi-cylindrical channel was 25 mm and distilled water was used as a working fluid. The filling ratio of the thermosyphon was fixed at 0.5 and the inclination angle was set to 60º. As the heat flux increases, nucleate boiling becomes dominant and the bursting motion starts to begin in the liquid pool at the evaporator section. The bursting liquid flow reaches the condenser section and changes the condensation regime from dropwise to filmwise by flooding the condenser wall, which results in the decrease of condensation heat transfer coefficient. In addition, the vigorous vapor generation which occurs in the liquid pool at the evaporator section disturbs the circulation of the condensate film from the condenser to the evaporator section. As a result, the local dry-out occurs on the evaporator section with increasing heat flux, so the boiling heat transfer coefficient is decreased. [This research was supported by the Ministry of Science and ICT through the National Research Foundation of Korea (NRF-2018H1D3A2000929).]

Author(s):  
Hongbin He ◽  
Biao Shen ◽  
Sumitomo Hidaka ◽  
Koji Takahashi ◽  
Yasuyuki Takata

Heat transfer characteristic of a closed two-phase thermosyphon with enhanced boiling surface is studied and compared with that of a copper mirror surface. Two-phase cooling improves heat transfer coefficient (HTC) a lot compared to single-phase liquid cooling. The evaporator surfaces, coated with a pattern of hydrophobic circle spots (non-electroplating Ni-PTFE, 0.5∼2 mm in diameter and 1.5–3 mm in pitch) on Cu substrates, achieve very high heat transfer coefficient and lower the incipience temperature overshoot using water as the working fluid. Sub-atmospheric boiling on the hydrophobic spot-coated surface shows a much better heat transfer performance. Tests with heat loads (30 W to 260 W) reveals the coated surfaces enhance nucleate boiling performance by increasing the bubbles nucleation sites density. Hydrophobic circle spots coated surface with diameter 1 mm, pitch 1.5 mm achieves the maximal heat transfer enhancement with the minimum boiling thermal resistance as low as 0.03 K/W. The comparison of three evaporator surfaces with same spot parameters but different coating materials is carried out experimentally. Ni-PTFE coated surface with immersion method performs the optimal performance of the thermosyphon.


Kerntechnik ◽  
2021 ◽  
Vol 86 (5) ◽  
pp. 365-374
Author(s):  
A. M. Refaey ◽  
S. Elnaggar ◽  
S. H. Abdel-Latif ◽  
A. Hamza

Abstract The nucleate boiling regime and two-phase flow are greater importance to the safety analysis of nuclear reactors. In this study, the boiling heat transfer in nuclear reactor is numerical investigated. The computational fluid dynamics (CFD) code, ANSYS Fluent 17.2 is used and the boiling model is employed. The numerical predictions obtained are compared with the experimental data reported by A. Hamza et al. [9]. An experimental test rig is designed and constructed to investigate the effect of cooling water chemistry control and the material of heater surface. CFD software, allows the detailed analysis of the two-phase flow and heat transfer. In this paper, we evaluate the accuracy of the boiling model implemented in the ANSYS Fluent code. This model is based on the heat flux partitioning approach and accommodates the heat flux due to single-phase convection, quenching and evaporation. The validation carried out of surfactant fluid/vapor two-phase flow inside the 2-D cylindrical boiling vessel. A heated horizontal pipe with stainless steel, Aluminum, and Zircalloy surface materials are used to numerically predict the field temperature and void fraction. Different surfactant concentrations ranging from 0, (pure water) to 1500 ppm, and heat fluxes ranging from 31 to 110 kW/m2 are used. The results of the predicted model depict that the addition of SDS Surfactant and increasing the heat flux improves the coefficient of boiling heat transfer for a given concentration. Also, it was found that the increasing of the concentration of aqueous surfactant solution increases the pool boiling heat transfer coefficient. The aqueous surfactant solution SDS improved the heat transfer coefficient of Aluminum, Zircalloy and stainless steel surface materials by 135%.138% and 120% respectively. The results of the numerical model are nearly in agreement with that measured in experimental.


Author(s):  
Yiding Cao ◽  
Mingcong Gao

This paper introduces a novel heat transfer mechanism that facilitates two-phase heat transfer while eliminating the so-called cavitation problem commonly encountered by a conventional pump. The heat transfer device is coined as the reciprocating-mechanism driven heat loop (RMDHL), which includes a hollow loop having an interior flow passage, an amount of working fluid filled within the loop, and a reciprocating driver. The hollow loop has an evaporator section, a condenser section, and a liquid reservoir. The reciprocating driver is integrated with the liquid reservoir and facilitates a reciprocating flow of the working fluid within the loop, so that liquid is supplied from the condenser section to the evaporator section under a substantially saturated condition and the so-called cavitation problem associated with a conventional pump is avoided. The reciprocating driver could be a solenoid-operated reciprocating driver for electronics cooling applications and a bellows-type reciprocating driver for high-temperature applications. Experimental study has been undertaken for a solenoid-operated heat loop in connection with high heat flux thermal management applications. Experimental results show that the heat loop worked very effectively and a heat flux as high as 300 W/cm2 in the evaporator section could be handled. The applications of the bellows-type reciprocating heat loop for gas turbine nozzle guide vanes and the leading edges of hypersonic vehicles are also illustrated. The new heat transfer device is expected to advance the current two-phase heat transfer device and open up a new frontier for further research and development.


Author(s):  
M. Hamayun Maqbool ◽  
Bjo¨rn Palm ◽  
R. Khodabandeh ◽  
Rashid Ali

Experiments have been performed to investigate heat transfer in a circular vertical mini channel made of stainless steel (AISI 316) with internal diameter of 1.70 mm and a uniformly heated length of 245 mm using ammonia as working fluid. The experiments are conducted for a heat flux range of 15 to 350 kW/m2 and mass flux range of 100 to 500 kg/m2s. The effects of heat flux, mass flux and vapour quality on the heat transfer coefficient are explored in detail. The experimental results show that the heat transfer coefficient increases with imposed wall heat flux while mass flux and vapour quality have no considerable effect. Experimental results are compared to predictive methods available in the literature for boiling heat transfer. The correlations of Cooper et al. [1] and Shah [3] are in good agreement with our experimental data.


2018 ◽  
Vol 26 (01) ◽  
pp. 1850001
Author(s):  
Yushazaziah Mohd-Yunos ◽  
Normah Mohd-Ghazali ◽  
Maziah Mohamad ◽  
Agus Sunjarianto Pamitran ◽  
Jong-Taek Oh

Heat transfer coefficient as an important characteristic in heat exchanger design is determined by the correlation developed from previous experimental work or accumulation of published data. Although discrepancies still exist between the existing correlations and practical data, several researchers claimed theirs as a generalized heat transfer correlation. Through optimization method, this study predicts the heat transfer coefficient of two-phase flow of propane in a small channel at the saturation temperature of 10[Formula: see text]C using two categories of correlation — superposition and asymptotic. Both methods consist of the contribution of nucleate boiling and forced convective heat transfer, the mechanisms that contribute to the total two-phase heat transfer coefficient, which become as two objective functions to be maximized. The optimization of experimental parameters of heat flux, mass flux, channel diameter and vapor quality is done by using genetic algorithm within a range of 5–20[Formula: see text]kW/m2, 100–250[Formula: see text]kg/m2[Formula: see text]s, 1.5–3[Formula: see text]mm and 0.009–0.99, respectively. In the result, the selected correlations under optimized condition agreed on the dominant mechanism at low and high vapor qualities are caused by the nucleate boiling and forced convective heat transfer, respectively. The optimization work served as an alternative approach in identifying optimized parameters from different correlations to achieve high heat transfer coefficient by giving a fast prediction of parameter range, particularly for the investigation of any new refrigerant. In parallel with some experimental works, a quick prediction is possible to reduce time and cost. From the four selected generalized correlations, Bertsch et al. show the closer trend with the reference experimental work until vapor quality of 0.6.


1998 ◽  
Vol 120 (2) ◽  
pp. 477-484 ◽  
Author(s):  
M. S. El-Genk ◽  
H. H. Saber

Heat transfer correlations were developed for the liquid film region, in the evaporator section of closed, two-phase, gravity-assisted thermosyphons in the following regimes: (a) laminar convection, at low heat fluxes, (b) combined convection, at intermediate heat fluxes, and (c) nucleate boiling, at high heat fluxes. These correlations were based on a data set consisting of a total of 305 points for ethanol, acetone, R-11, and R-113 working fluids, wall heat fluxes of 0.99–52.62 kW/m2, working fluid filling ratios of 0.01–0.62, inner diameters of 6–37 mm, evaporator section lengths of 50–609.6 mm, and vapor temperatures of 261–352 K. The combined convention data were correlated by superimposing the correlations of laminar convention and nucleate boiling using a power law approach, to ensure smooth transition among the three heat transfer regimes. The three heat transfer correlations developed in this work are within ±15 percent of experimental data.


Author(s):  
Yanfeng Fan ◽  
Ibrahim Hassan

Flow oscillation is a crucial issue for the development of flow boiling heat transfer in the applications. Inlet orifice has been proven be an option to eliminate the oscillation. However, the effects of inlet orifice on critical heat flux and flow boiling heat transfer coefficient are lack of study. In this work, the effects of inlet restriction on critical heat flux and heat transfer coefficient in single horizontal microtube under uniform heating condition is experimentally investigated using FC-72 as working fluid. A stainless steel microtube with an inner diameter of 889 μm is selected as main microtube. Two smaller microtubes are assembled at the inlet of main microtube to achieve the restriction configurations of 50% and 20% area ratios. The experimental measurement is carried out at mass fluxes ranging from 160–870 kg/m2·s and heat fluxes varying from 6–170 kW/m2. Two saturation pressures, 10 and 45 kPa, are tested. The experimental results of critical heat flux and two phase heat transfer coefficient obtained in the microtube without orifice are compared with the existing correlations. The addition of an orifice does not enhance the normal critical heat flux but increases the premature critical heat flux. In aspect of heat transfer, the orifice shows improvement on heat transfer coefficient at low mass flux and high saturation pressure.


Author(s):  
Ronald Akbar ◽  
Jong Taek Oh ◽  
Agus Sunjarianto Pamitran

Various experiments have been conducted on the heat transfer coefficient of two-phase flow boiling in mini channel tubes. In addition to obtaining data on the heat transfer coefficients through experiments, many researchers have also compared their experimental data using existing correlations. This research aims to determine the characteristics of the heat transfer coefficient of refrigerant R290 from the data used by processing and knowing the best heat transfer coefficient correlation in predicting the experimental data so that the results are expected to be a reference for designing a heat exchanger or for further research. The experimental data predicted is the two-phase flow boiling in a horizontal tube 3 mm diameter, with the mass flux of 50-180 kg/m2s, heat flux of 5-20 kW/m2, saturation temperature of 0-11 °C, and vapor quality of 0-1. The correlation used in this research is based on the asymptotic flow model, where the model is a combination of the nucleate and convective flow boiling mechanisms. The results show an effect of mass flux and heat flux on the experimental heat transfer coefficient and the predicted R290 heat transfer coefficient with asymptotic correlations had a good and similar result to the experimental data.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4891
Author(s):  
Magdalena Piasecka ◽  
Kinga Strąk

This paper reports the results of heat transfer during refrigerant flow in rectangular mini-channels at stationary conditions. The impacts of selected parameters on boiling are discussed, i.e., thermal and flow parameters, dimensions and orientation of the channels. Four refrigerants (FC-72, HFE-649, HFE-7000 and HFE-7100) were used as the working fluid. Research was carried out on the experimental set-up with the test section with a single rectangular mini-channel of 180 mm long and with a group of five parallel mini-channels, each 32 mm long. The temperature of the mini-channel’s heated wall was measured by infrared thermography. Local values of the heat transfer coefficient at the contact surface between the fluid and the plate were calculated using the 1D mathematical method. The results are presented as the relationship between the heat transfer coefficient and the distance along the mini-channel length and boiling curves. Two-phase flow patterns are shown. Moreover, the results concerning various refrigerants and the use of modified heater surfaces are discussed. The main factors influencing the heat transfer process were: mini-channel inclination to the horizontal pane (the highest heat transfer coefficient at 270° and 0°), using modified heater surfaces (especially electroerosion texturing and vibration-assisted laser No. 2 texturing) and working fluids (FC-72 and HFE-7000).


Author(s):  
Wei Tong ◽  
Alireza Ganjali ◽  
Omidreza Ghaffari ◽  
Chady Alsayed ◽  
Luc Frechette ◽  
...  

Abstract In a two-phase immersion cooling system, boiling on the spreader surface has been experimentally found to be non-uniform, and it is highly related to the surface temperature and the heat transfer coefficient. An experimentally obtained temperature-dependent boiling heat transfer coefficient has been applied to a numerical model to investigate the spreader's cooling performance. It is found that the surface temperature distribution becomes less uniform with higher input power. But it is more uniform when the thickness is increased. By defining the characteristic temperatures that represent different boiling regimes on the surface, the fraction of the surface area that has reached the critical heat flux has been numerically calculated, showing that increasing the thickness from 1 mm to 6 mm decreases the critical heat flux reached area by 23% at saturation liquid temperatures. Therefore, on the thicker spreader, more of the surface is utilized for nucleate boiling while localized hot regions that lead to surface dry-out are avoided. At a base temperature of 90 oC, the optimal thickness is found to be 4 mm, beyond which no significant improvement in heat removal can be obtained. Lower coolant temperatures can further increase the heat removal; it is reduced from an 18% improvement in the input power for the 1 mm case to only 3% in the 6 mm case for a coolant temperature drop of 24 oC. Therefore, a trade-off exists between the cost of maintaining the low liquid temperature and the increased heat removal capacity.