scholarly journals Method for Calibration of Left Ventricle Material Properties Using Three-Dimensional Echocardiography Endocardial Strains

2019 ◽  
Vol 141 (9) ◽  
Author(s):  
Yaghoub Dabiri ◽  
Kevin L. Sack ◽  
Nuno Rebelo ◽  
Peter Wang ◽  
Yunjie Wang ◽  
...  

We sought to calibrate mechanical properties of left ventricle (LV) based on three-dimensional (3D) speckle tracking echocardiographic imaging data recorded from 16 segments defined by American Heart Association (AHA). The in vivo data were used to create finite element (FE) LV and biventricular (BV) models. The orientation of the fibers in the LV model was rule based, but diffusion tensor magnetic resonance imaging (MRI) data were used for the fiber directions in the BV model. A nonlinear fiber-reinforced constitutive equation was used to describe the passive behavior of the myocardium, whereas the active tension was described by a model based on tissue contraction (Tmax). isight was used for optimization, which used abaqus as the forward solver (Simulia, Providence, RI). The calibration of passive properties based on the end diastolic pressure volume relation (EDPVR) curve resulted in relatively good agreement (mean error = −0.04 ml). The difference between the experimental and computational strains decreased after segmental strain metrics, rather than global metrics, were used for calibration: for the LV model, the mean difference reduced from 0.129 to 0.046 (circumferential) and from 0.076 to 0.059 (longitudinal); for the BV model, the mean difference nearly did not change in the circumferential direction (0.061) but reduced in the longitudinal direction from 0.076 to 0.055. The calibration of mechanical properties for myocardium can be improved using segmental strain metrics. The importance of realistic fiber orientation and geometry for modeling of the LV was shown.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tomoyo Y. Irie ◽  
Tohru Irie ◽  
Alejandro A. Espinoza Orías ◽  
Kazuyuki Segami ◽  
Norimasa Iwasaki ◽  
...  

AbstractThis study investigated in vivo the three-dimensional distribution of CT attenuation in the lumbar spine pedicle wall measured in Hounsfield Unit (HU). Seventy-five volunteers underwent clinical lumbar spine CT scans. Data was analyzed with custom-written software to determine the regional variation in pedicle wall attenuation values. A cylindrical coordinate system oriented along the pedicle’s long axis was used to calculate the pedicular wall attenuation distribution three-dimensionally and the highest attenuation value was identified. The pedicular cross-section was divided into four quadrants: lateral, medial, cranial, and caudal. The mean HU value for each quadrant was calculated for all lumbar spine levels (L1–5). The pedicle wall attenuation was analyzed by gender, age, spinal levels and anatomical quadrant. The mean HU values of the pedicle wall at L1 and L5 were significantly lower than the values between L2–4 in both genders and in both age groups. Furthermore, the medial quadrant showed higher HU values than the lateral quadrant at all levels and the caudal quadrant showed higher HU values at L1–3 and lower HU values at L4–5 than the cranial quadrant. These findings may explain why there is a higher incidence of pedicle screw breach in the pedicle lateral wall.


2013 ◽  
Vol 113 (suppl_1) ◽  
Author(s):  
Liudmila Zakharova ◽  
Hikmet Nural ◽  
James R Nimlos ◽  
Snjezana Popovic ◽  
Lorraine Feehery ◽  
...  

A pilot clinical study using autologous c-Kit+ cells showed improvement in cardiac functions in congestive heart failure (CHF), however, it is unclear if c-Kit+ cells isolated from CHF hearts are equally as potent as cells from controls. To test the potency of CHF c-Kit+ cells, myocardial infarction (MI) was created by permanent ligation of the left anterior descending coronary artery. Six weeks after MI, animals with left ventricle end-diastolic pressure (LVEDP) ≥20 mmHg and scar size ≥30% of left ventricle (LV) were designated as CHF rats. We found that CHF atrial explants generated less c-Kit+ cells compared to shams (15.7% vs. 11% sham vs. CHF). CHF c-Kit+ cells exhibited elevated levels of epicardial to mesenchymal transition markers, including Snail (2.5 fold) and Pai1 (3 fold), while the expression level of epithelial marker, E-cadherin was 3 fold lower in CHF c-Kit+ cells. Moreover, CHF c-Kit+ cells exhibited reduced gene expressions of pluripotency markers; 2.1 fold decrease in Nanog and 4.5 fold decrease in Sox 2 compared to sham cells. To evaluate the potency of the c-Kit+ cells, 1 x 10 6 cells isolated from CHFs or shams were delivered to 3 weeks post-MI CHF hearts. Cells were pre-labeled with GFP to enable their tracing in vivo and delivered to the infarcted myocardium via left coronary vein by a retrograde coronary sinus cell infusion (RCI). RCI delivery resulted in a cell distribution of LV (30%), right atrium (30%) and right ventricle (20%), while only 10% of cells were found in a left atrium. Three weeks after cells delivery, rats transplanted with sham c-Kit+ cells showed improved LVEDP (29.4 ± 6 vs. 11.7 ± 3.5 mmHg, CHF vs. CHF+ sham c-Kit+ cells) and a rise in peak rate of pressure (dPdt max) (3988 ± 520 vs. 5333 ± 597 mmHg/s). In contrast, no functional improvement was detected in rats transplanted with CHF c-Kit+ cells. Histological analysis demonstrated that transplanted c-Kit+/GFP+ cells were mostly incorporated into blood vessels and co-localized with endothelial marker vWf, and α-smooth muscle actin. Our results showed that left coronary vein is an efficient route for c-Kit+ cell delivery and that c-Kit+ cells isolated from CHF rats are less potent when transplanted in chronic heart failure rat model compared to those isolated from control.


1978 ◽  
Vol 235 (2) ◽  
pp. H247-H250 ◽  
Author(s):  
L. Role ◽  
D. Bogen ◽  
T. A. McMahon ◽  
W. H. Abelmann

Principal radii of curvature and wall thickness were measured at the apex and three other loci on the free wall of the left ventricle in 16 rat hearts that had been fixed at end-diastolic pressure. The law of Laplace was applied to calculate the mean tensile stress at each locus. No significant variation was found among the nonapical loci, but apical stress was approximately twice the stress calculated for any nonapical locus. The higher stresses that must be borne by the apex may be a predisposing factor for apical aneurysm in certain cardiomyopathies such as Chagas' disease. These higher stresses may also help to promote apical aneurysms in patients with ischemic heart disease.


1976 ◽  
Vol 40 (4) ◽  
pp. 625-629 ◽  
Author(s):  
R. L. Coon ◽  
N. C. Lai ◽  
J. P. Kampine

A newly developed, dual-function pH and PCO2 sensor was evaluated in this study. The sensors were placed in the femoral arteries of dogs anesthetized with sodium pentobarbital. Comparisons were made between systemic arterial pH and PCO2 measured using the sensor and those measured from blood samples drawn at 15-min intervals over a 7-h period using a bench instrument. The mean pH of the bench instrument measurements was 7.43. The mean difference of the sensor measurements from the bench instrument measurements for 207 comparisons was 0.0003 pH +/- 0.061 SD. The mean PCO2 of the bench instrument measurements was 40 mmHg. The mean difference of the sensor measurements from those of the bench instrument for 212 comparisons was -1.43 mmHg +/- 5.17 SD. The sensors performed equally well in the presence of metabolic or respiratory acidosis and alkalosis. The dual-function sensors evaluated in this study are useful for trend monitoring of pH and PCO2 over at least a 7-h period without recalibration. With improvement in the consistency of sensor construction, these sensors will be reliable in vivo sensing devices for blood pH and PCO2 and thus valuable research and clinical instruments.


Materials ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 203 ◽  
Author(s):  
Chun-Hao Tsai ◽  
Chih-Hung Hung ◽  
Che-Nan Kuo ◽  
Cheng-Yu Chen ◽  
Yu-Ning Peng ◽  
...  

Recently, cases of bone defects have been increasing incrementally. Thus, repair or replacement of bone defects is gradually becoming a huge problem for orthopaedic surgeons. Three-dimensional (3D) scaffolds have since emerged as a potential candidate for bone replacement, of which titanium (Ti) alloys are one of the most promising candidates among the metal alloys due to their low cytotoxicity and mechanical properties. However, bioactivity remains a problem for metal alloys, which can be enhanced using simple immersion techniques to coat bioactive compounds onto the surface of Ti–6Al–4V scaffolds. In our study, we fabricated magnesium-calcium silicate (Mg–CS) and chitosan (CH) compounds onto Ti–6Al–4V scaffolds. Characterization of these surface-modified scaffolds involved an assessment of physicochemical properties as well as mechanical testing. Adhesion, proliferation, and growth of human Wharton’s Jelly mesenchymal stem cells (WJMSCs) were assessed in vitro. In addition, the cell attachment morphology was examined using scanning electron microscopy to assess adhesion qualities. Osteogenic and mineralization assays were conducted to assess osteogenic expression. In conclusion, the Mg–CS/CH coated Ti–6Al–4V scaffolds were able to exhibit and retain pore sizes and their original morphologies and architectures, which significantly affected subsequent hard tissue regeneration. In addition, the surface was shown to be hydrophilic after modification and showed mechanical strength comparable to natural bone. Not only were our modified scaffolds able to match the mechanical properties of natural bone, it was also found that such modifications enhanced cellular behavior such as adhesion, proliferation, and differentiation, which led to enhanced osteogenesis and mineralization downstream. In vivo results indicated that Mg–CS/CH coated Ti–6Al–4V enhances the bone regeneration and ingrowth at the critical size bone defects of rabbits. These results indicated that the proposed Mg–CS/CH coated Ti–6Al–4V scaffolds exhibited a favorable, inducive micro-environment that could serve as a promising modification for future bone tissue engineering scaffolds.


2013 ◽  
Vol 01 (01) ◽  
pp. 030-032
Author(s):  
Amit Sharma ◽  
Abhimanyu Singh Chauhan ◽  
Jagmohan Lal ◽  
Ravneet Kaur ◽  
Navreet Sandhu

AbstractTraditional materials utilized for dental applications have been selected based on their mechanical properties and ability to remain inert in vivo; this selection process has provided materials that satifisfy physiological loading conditions but do not duplicate the mechanical, chemical, and architectural properties of bone. The less than optimal surface properties of conventional materials have resulted in clinical complications that necessitate surgical removal of many such failed bone implants due to insufficient bonding to juxtaposed bone. Due to unique surface and mechanical properties, as well as the ability to simulate the three-dimensional architecture of physiological bone, one possible consideration for the next generation of orthopedic and dental implants with improved efficacy are nanophase materials.


2011 ◽  
Vol 300 (5) ◽  
pp. R1079-R1090 ◽  
Author(s):  
Erin K. Englund ◽  
Christopher P. Elder ◽  
Qing Xu ◽  
Zhaohua Ding ◽  
Bruce M. Damon

The purposes of this study were to create a three-dimensional representation of strain during isometric contraction in vivo and to interpret it with respect to the muscle fiber direction. Diffusion tensor MRI was used to measure the muscle fiber direction of the tibialis anterior (TA) muscle of seven healthy volunteers. Spatial-tagging MRI was used to measure linear strains in six directions during separate 50% maximal isometric contractions of the TA. The strain tensor (E) was computed in the TA's deep and superficial compartments and compared with the respective diffusion tensors. Diagonalization of E revealed a planar strain pattern, with one nonzero negative strain (εN) and one nonzero positive strain (εP); both strains were larger in magnitude ( P < 0.05) in the deep compartment [εN = −40.4 ± 4.3%, εP = 35.1 ± 3.5% (means ± SE)] than in the superficial compartment (εN = −24.3 ± 3.9%, εP = 6.3 ± 4.9%). The principal shortening direction deviated from the fiber direction by 24.0 ± 1.3° and 39.8 ± 6.1° in the deep and superficial compartments, respectively ( P < 0.05, deep vs. superficial). The deviation of the shortening direction from the fiber direction was due primarily to the lower angle of elevation of the shortening direction over the axial plane than that of the fiber direction. It is concluded that three-dimensional analyses of strain interpreted with respect to the fiber architecture are necessary to characterize skeletal muscle contraction in vivo. The deviation of the principal shortening direction from the fiber direction may relate to intramuscle variations in fiber length and pennation angle.


2006 ◽  
Vol 105 (4) ◽  
pp. 561-567 ◽  
Author(s):  
Christopher R. Mascott

Object Image guidance systems involving the use of frameless referencing of surgical space to compile volumetric imaging data sets recently have come into widespread use. Few studies have addressed the true intraoperative surgical accuracy (that is, the application accuracy) of these systems except in a subjective manner. Calculated accuracies given by the systems do not necessarily reflect true intraoperative accuracy. Methods To objectively assess the stereotactic accuracy of a frameless image guidance system using optical spatial referencing, the author analyzed postoperative magnetic resonance (MR) images after placement of depth electrodes for the investigation of epilepsy. Preoperative planning for the treatment of seven patients included implanting skull fiducial screws and obtaining computed tomography/MR fusion images by using ImMerge image fusion software on the StealthStation (Medtronic, Inc.). A total of 42 electrodes were placed. Postoperative volumetric MR images were fused with preoperative study images. The difference between the planned electrode trajectories and targets and the visualized electrodes was measured in stereotactic space. Conclusions The mean distance between the distal electrode contact and the distal end of the planned trajectory for the 42 targets was 3 ± 1.5 mm. The most common error was in depth. The author’s technique did not involve rigid skull fixation of electrodes because they were subsequently tunneled subcutaneously and later removed at the bedside of the patient. Errors in depth were known to be due to traction at the time of tunneling and not due to stereotactic factors. Correcting for depth along the electrode trajectory, the mean accuracy was found to be 2.4 ± 1 mm.