An Experimental Investigation of Adiabatic Film Cooling Effectiveness and Heat Transfer Coefficient on a Transonic Squealer Tip

2019 ◽  
Vol 141 (9) ◽  
Author(s):  
Andrew J. Saul ◽  
Peter T. Ireland ◽  
John D. Coull ◽  
Tsun Holt Wong ◽  
Haidong Li ◽  
...  

The effect of film cooling on a transonic squealer tip has been examined in a high speed linear cascade, which operates at engine-realistic Mach and Reynolds numbers. Tests have been performed on two uncooled tip geometries with differing pressure side rim edge radii, and a cooled tip matching one of the uncooled cases. The pressure sensitive paint technique has been used to measure adiabatic film cooling effectiveness on the blade tip at a range of tip gaps and coolant mass flow rates. Complementary tip heat transfer coefficients have been measured using transient infrared thermography, and the effects of the coolant film on the tip heat transfer and engine heat flux were examined. The uncooled data show that the tip heat transfer coefficient distribution is governed by the nature of flow reattachments and impingements. The squealer tip can be broken down into three regions, each exhibiting a distinct response to a change in the tip gap, depending on the local behavior of the overtip leakage flow. Complementary computational fluid dynamics (CFD) shows that the addition of casing motion causes no change in the flow over the pressure side rim. Injected coolant interacts with the overtip leakage flow, which can locally enhance the tip heat transfer coefficient. The film effectiveness is dependent on both the coolant mass flow rate and tip clearance. At increased coolant mass flow, areas of high film effectiveness on the pressure side rim coincide strongly with a net heat flux reduction and in the subsonic tip region with low heat transfer coefficient.

Author(s):  
Andrew J. Saul ◽  
Peter T. Ireland ◽  
John D. Coull ◽  
Tsun Holt Wong ◽  
Haidong Li ◽  
...  

The effect of film cooling on a high pressure turbine blade with an open squealer tip has been examined in a high speed linear cascade. The cascade operates at engine realistic Mach and Reynolds numbers, producing transonic flow conditions over the blade tip. Tests have been performed on two uncooled tip geometries with differing pressure side rim edge radii, and a cooled tip matching one of the uncooled cases. The pressure sensitive paint technique has been used to measure adiabatic film cooling effectiveness on the blade tip at a range of tip gaps and coolant mass flow rates. Complementary tip heat transfer coefficients (HTC) have been measured using transient infrared thermography, and the effects of the coolant film on the tip heat transfer and engine heat flux examined. The uncooled data show that the tip heat transfer coefficient distribution is governed by the nature of flow reattachments and impingements. The squealer tip can be broken down into three regions, each exhibiting a distinct response to a change in the tip gap, depending on the local behaviour of the overtip leakage flow. The edge radius of the pressure side rim causes the overtip leakage flow to change dramatically at low clearance. Complementary CFD shows that the addition of casing motion causes no further change on the pressure side rim. Injected coolant interacts with the overtip leakage flow, which can locally enhance the tip heat transfer coefficient compared to the uncooled tip. The film effectiveness is dependent on both the coolant mass flow rate and tip clearance. At increased coolant mass flow, areas of high film effectiveness on the pressure side rim coincide strongly with a net heat flux reduction and in the subsonic tip region with low heat transfer coefficient.


2004 ◽  
Vol 10 (5) ◽  
pp. 345-354 ◽  
Author(s):  
Jan Dittmar ◽  
Achmed Schulz ◽  
Sigmar Wittig

The demand of improved thermal efficiency and high power output of modern gas turbine engines leads to extremely high turbine inlet temperature and pressure ratios. Sophisticated cooling schemes including film cooling are widely used to protect the vanes and blades of the first stages from failure and to achieve high component lifetimes. In film cooling applications, injection from discrete holes is commonly used to generate a coolant film on the blade's surface.In the present experimental study, the film cooling performance in terms of the adiabatic film cooling effectiveness and the heat transfer coefficient of two different injection configurations are investigated. Measurements have been made using a single row of fanshaped holes and a double row of cylindrical holes in staggered arrangement. A scaled test model was designed in order to simulate a realistic distribution of Reynolds number and acceleration parameter along the pressure side surface of an actual turbine guide vane. An infrared thermography measurement system is used to determine highly resolved distribution of the models surface temperature. Anin-situcalibration procedure is applied using single embedded thermocouples inside the measuring plate in order to acquire accurate local temperature data.All holes are inclined 35° with respect to the model's surface and are oriented in a streamwise direction with no compound angle applied. During the measurements, the influence of blowing ratio and mainstream turbulence level on the adiabatic film cooling effectiveness and heat transfer coefficient is investigated for both of the injection configurations.


Author(s):  
Jae Su Kwak ◽  
Je-Chin Han

The detailed distributions of heat transfer coefficient and film cooling effectiveness on a gas turbine blade tip were measured using a hue detection based transient liquid crystal technique. Tests were performed on a five-bladed linear cascade with blow down facility. The blade was a 2-dimensional model of a first stage gas turbine rotor blade with a profile of the GE-E3 aircraft gas turbine engine rotor blade. The Reynolds number based on cascade exit velocity and axial chord length was 1.1 × 106 and the total turning angle of the blade was 97.7°. The overall pressure ratio was 1.32 and the inlet and exit Mach number were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. The blade model was equipped with a single row of film cooling holes at both the tip portion along the camber line and near the tip region of the pressure-side. All measurements were made at the three different tip gap clearances of 1%, 1.5%, and 2.5% of blade span and the three blowing ratios of 0.5, 1.0, and 2.0. Results showed that, in general, heat transfer coefficient and film effectiveness increased with increasing tip gap clearance. As blowing ratio increased, heat transfer coefficient decreased, while film effectiveness increased. Results also showed that adding pressure-side coolant injection would further decrease blade tip heat transfer coefficient but increase film effectiveness.


2021 ◽  
Vol 3 (12) ◽  
Author(s):  
Patrick Jagerhofer ◽  
Jakob Woisetschläger ◽  
Gerhard Erlacher ◽  
Emil Göttlich

Abstract A measurement technique for recording convective heat transfer coefficient and adiabatic film cooling effectiveness in demanding environments with highly curved surfaces and limited optical access, such as turbomachinery, is presented. Thermography and tailor-made flexible heating foils are used in conjunction with a novel multistep calibration and data reduction method. This method compensates for sensor drift, angle dependence of surface emissivity and window transmissivity, heat flux inhomogeneity, and conductive losses. The 2D infrared images are mapped onto the 3D curved surfaces and overlapped, creating surface maps of heat transfer coefficient and film cooling effectiveness covering areas significantly larger than the window size. The measurement technique’s capability is demonstrated in a sector-cascade test rig of a turbine center frame (TCF), an inherent component of modern two-spool turbofan engines. The horseshoe vortices were found to play a major role for the thermal integrity of turbine center frames, as they lead to a local increase in heat transfer, and at the same instance, to a reduction of film cooling effectiveness. It was also found that the horseshoe vortices lift off from the curved surface at 50% hub length, resulting in a pair of counter-rotating vortices. The measurement technique was validated by comparing the data against flat plate correlations and also by the linear relation between temperature difference and heat flux. This study is complemented with an extensive error and uncertainty analysis. Article highlights This paper presents an accurate measurement technique for heat transfer and film cooling on 3D curved surfaces with limited optical access using flexible tailor-made heating foils, infrared thermography and a high-fidelity multistep calibration process. Graphical abstract


Author(s):  
Chun-yi Yao ◽  
Hui-ren Zhu ◽  
Cun-liang Liu ◽  
Bo-lun Zhang ◽  
Xin-lei Li

Abstract A number of experimental studies have been performed to study the effect of geometric and aerodynamic parameters on the film cooling performance on the flat plate and turbine blade, however, the experimental investigations on a fully-cooled turbine vane is limited, especially at different density ratios. Consequently, an experiment on a fully-cooled turbine vane with multi-row film cooling holes was carried out to investigate the effect of mass flow ratio and density ratio on the film cooling performance, in which the film cooling effectiveness and heat transfer coefficient was measured by transient liquid crystal. The mainstream inlet Reynolds number based on the inlet velocity and the true chord length is 120000 and the mainstream turbulence intensity is 15%, three mass flow ratios of 5.5%, 8.4% and 11% and two density ratios of 1.0 and 1.5 were tested. The air was selected as the mainstream, the air and carbon dioxide were independently selected as secondary flow to produce two density ratios of 1.0 and 1.5. The test vane is similar in geometry to a first stage turbine vane of a normal aeroengine. Two cavities were manufactured in the test vane to feed 18 rows of film cooling holes. Results show that with the mass flow ratio increasing for DR = 1.0 and 1.5, the film cooling effectiveness on pressure side gradually increases, however, that on the suction side gradually decreases. Generally, increased density ratio produces higher film cooling effectiveness because the injection momentum was reduced, however, the film cooling effectiveness on the suction side for DR = 1.5 is lower than that for DR = 1.0. The coolant outflow significantly enhances the surface heat transfer coefficient for 0 < S/C < 0.5 and S/C < −0.5. The heat transfer coefficient in the leading edge is less affected by the density ratio, however, the increase in density ratio reduces the heat transfer coefficient ratio in other regions, especially for large mass flow ratios.


Author(s):  
Chunyi Yao ◽  
Zheng Zhang ◽  
Bo-lun Zhang ◽  
Hui Ren Zhu ◽  
Cun Liang Liu

Abstract The objective of this experimental investigation was to determine the cooling performance of a fully cooled vane with 18 rows of cylinder cooling holes. The exit Reynolds number in the wind tunnel normalized by the true chord was 500,000 with a turbulence intensity of 15%. The film cooling effectiveness and heat transfer coefficient distribution were obtained by the transient liquid crystal technology, three mass flow ratios (MFR=7.0%, 9.9%, 11%) and two density ratios (DR=1.0, 1.5) were tested. The results show that the film cooling effectiveness distribution on the suction side is more uniform and the coolant injection trajectory is much longer than that on the pressure side. As the density ratio increasing to 1.5, the more laterally uniform film cooling effectiveness contour on the pressure side is observed and the spatially averaged film cooling effectiveness is increased by 11%∼43%. For the MFR=7.0%, the coolant injection with low momentum thickens the boundary layer and reduces the heat transfer coefficient in the mid-chord region of the pressure side. Both the increased mass flow ratio and decreased density ratio result in a higher heat transfer coefficient, while do not alter the distribution trend. By calculating the heat flux ratio, the reduction in the heat flux at DR=1.5 is found to be within 20% in most areas than that of DR=1.0 on the vane surface.


Author(s):  
Mats Kinell ◽  
Esa Utriainen ◽  
Hossein Nadali Najafabadi ◽  
Matts Karlsson ◽  
Botond Barabas

In order to protect a solid surface exposed to high temperature gaseous flows, e.g. gas turbines and rocket engines, a second gas at lower temperature may be introduced into the hot boundary layer, i.e. one obtains a three temperature problem. The impact of the film cooling on a prototype vane due to variation in blowing ratio, the shape of the hole-outlet and position has been experimentally investigated. The semi-infinite and low conductive test object, initially at a uniform temperature, was exposed to a sudden step change in main flow temperature and a time-resolved surface temperature was measured using an IR camera. By assuming constant values of the heat transfer coefficient and the film cooling effectiveness over time, the heat equation was solved using least squares. The prototype vane was tested for different film cooling row positions on the pressure and suction side. Both cylindrical as well as fan shaped holes were investigated with and without showerhead cooling. The resulting heat transfer coefficient and film cooling effectiveness on the pressure side is compared to flat plate studies and to the results from the suction side. Also, the applicability of using superposition on showerhead cooling and on single/double rows is investigated. Furthermore, the results are compared to other published airfoil film cooling experiments and to CFD analysis for which conclusions are drawn on quantitative and qualitative capabilities of this tool.


2003 ◽  
Vol 125 (3) ◽  
pp. 494-502 ◽  
Author(s):  
Jae Su Kwak ◽  
Je-Chin Han

The detailed distributions of heat transfer coefficient and film cooling effectiveness on a gas turbine blade tip were measured using a hue detection based transient liquid crystals technique. Tests were performed on a five-bladed linear cascade with blow-down facility. The Reynolds number based on cascade exit velocity and axial chord length was 1.1×106 and the total turning angle of the blade was 97.7°. The overall pressure ratio was 1.2 and the inlet and exit Mach numbers were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. The blade model was equipped with a single row of film cooling holes at both the tip portion along the camber line and near the tip region of the pressure side. All measurements were made at the three different tip gap clearances of 1.0%, 1.5%, and 2.5% of blade span and the three blowing ratios of 0.5, 1, and 2. Results showed that, in general, heat transfer coefficient and film effectiveness increased with increasing tip gap clearance. As blowing ratio increased, heat transfer coefficient decreased, while film effectiveness increased. Results also showed that adding pressure side coolant injection would further decrease the blade tip heat transfer coefficient but increase film-cooling effectiveness.


Author(s):  
A. Arisi ◽  
J. Phillips ◽  
W. F. Ng ◽  
S. Xue ◽  
H. K. Moon ◽  
...  

Detailed heat transfer coefficient (HTC) and film cooling effectiveness (Eta) distribution on a squealer tipped first stage rotor blade were measured using an infrared (IR) technique. The blade tip design, obtained from a Solar Turbines Inc. gas turbine, consisted of double purge hole exits and four ribs within the squealer cavity, with a bleeder exit port on the pressure side close to the trailing edge. The tests were carried out in a transient linear transonic wind tunnel facility under land-based engine representative Mach/Reynolds number. Measurements were taken at an inlet turbulent intensity of Tu = 12%, with exit Mach numbers of 0.85 (Reexit=9.75×105) and 1.0 (Reexit = 1.15×106) with the Reynolds number based on the blade axial chord and the cascade exit velocity. The tip clearance was fixed at 1% (based on engine blade span) with a purge flow blowing ratio BR = 1.0. At each test condition, an accompanying numerical study was performed using Reynolds Averaged Navier Stokes (RANS) equations solver ANSYS Fluent to further understand the tip flow characteristics. The results showed that the tip purge flow has a blocking effect on the leakage flow path. Furthermore, the ribs significantly altered the flow (and consequently heat transfer) characteristics within the squealer tip cavity resulting in a significant reduction in film cooling effectiveness. This was attributed to increased coolant-leakage flow mixing due to increased recirculation within the squealer cavity. Overall, the peak heat transfer coefficient on the cavity floor increased with exit Mach/Reynolds number.


Author(s):  
Bo-lun Zhang ◽  
Li Zhang ◽  
Hui-ren Zhu ◽  
Jian-sheng Wei ◽  
Zhong-yi Fu

Film cooling performance of the double-wave trench was numerically studied to improve the film cooling characteristics. Double-wave trench was formed by changing the leading edge and trailing edge of transverse trench into cosine wave. The film cooling characteristics of transverse trench and double-wave trench were numerically studied using Reynolds Averaged Navier Stokes (RANS) simulations with realizable k-ε turbulence model and enhanced wall treatment. The film cooling effectiveness and heat transfer coefficient of double-wave trench at different trench width (W = 0.8D, 1.4D, 2.1D) conditions are investigated, and the distribution of temperature field and flow field were analyzed. The results show that double-wave trench effectively improves the film cooling effectiveness and the uniformity of jet at the downstream wall of the trench. The span-wise averaged film cooling effectiveness of the double-wave trench model increases 20–63% comparing with that of the transverse trench at high blowing ratio. The anti-counter-rotating vortices which can press the film on near-wall are formed at the downstream wall of the double-wave trench. With the double-wave trench width decreasing, the film cooling effectiveness gradually reduces at the hole center-line region of the downstream trench. With the increase of the blowing ratio, the span-wise averaged heat transfer coefficient increases. The span-wise averaged heat transfer coefficient of the double-wave trench with 0.8D and 2.1D trench width is higher than that of the double-wave trench with 1.4D trench width at the high blowing ratio conditions.