Experimental Study on the Effect of Low Acute Side Angles on Heat Transfer in Rhombic Shaped Microchannel

2018 ◽  
Vol 141 (2) ◽  
Author(s):  
Sunil K. Dwivedi ◽  
Sandip K. Saha

This experimental study on rhombic shaped microchannels was conducted to understand the effect of a low acute side angle on the Nusselt number and compare the results with the published numerical results for H1 (axially constant heat flux and circumferentially constant temperature) and H2 (constant axial and circumferential wall heat flux) boundary conditions. The hydraulic and heat transfer characteristics of the rhombic geometry with a side angle of 30 deg for different mass flow rates and heat flux inputs are obtained using a three-dimensional (3D) conjugate heat transfer model, which is validated with the experimental results. It is found that the average Nusselt number obtained from the experimental and numerical results can be approximated closely with that computed using the H1 boundary condition. The local Nusselt number of hydrodynamically and thermally developed regions obtained from the numerical analysis is compared with a correlation for the H1 boundary condition. These results will be useful in design and optimization of a rhombic shaped microchannel for electronic cooling applications.

Author(s):  
Ivan Otic

Abstract One important issue in understanding and modeling of turbulent heat transfer is the behavior of fluctuating temperature close to the wall. Common engineering computational approach assumes constant heat flux boundary condition on heated walls. In the present paper constant heat flux boundary condition was assumed and effects of temperature fluctuations are investigated using large eddy simulations (LES) approach. A series of large eddy simulations for two geometries is performed: First, forced convection in channels and second, forced convection over a backward facing step. LES simulation data is statistically analyzed and compared with results of direct numerical simulations (DNS) from the literature which apply three cases of heat flux boundary conditions: 1. ideal heat flux boundary condition, 2. non-ideal heat flux boundary condition, 3. conjugate heat transfer boundary condition. For low Prandtl number flows LES results show that, despite very good agreement for velocities and mean temperature, predictions of temperature fluctuations may have strong deficiencies if simplified boundary conditions are applied.


1994 ◽  
Vol 116 (3) ◽  
pp. 536-542 ◽  
Author(s):  
A. A. Kornhauser ◽  
J. L. Smith

Heat transfer during compression and expansion can be out of phase with bulk gas-wall temperature difference. An ordinary convective heat transfer model is incapable of predicting this phenomenon. Expressions for compression/expansion heat transfer developed from simple conduction models use a complex heat transfer coefficient. Thus, heat flux consists of one part proportional to temperature difference plus a second part proportional to rate of change of temperature. Surface-averaged heat flux was calculated from experimental pressure-volume data for piston-cylinder gas springs over a range of speeds, pressures, gases, and geometries. The complex Nusselt number model proved capable of correlating both magnitude and phase of the measured heat transfer as functions of an oscillation Peclet number.


2021 ◽  
Vol 9 (12) ◽  
pp. 686-695
Author(s):  
Waleed Abdulhadiethbayah ◽  

Many engineering and industrial applications always seek to find ways to dissipate heat from heated surfaces used in these industries. As it is involved in the cooling of electronic parts and electrical transformers, as well as the design of solar collectors, in addition to being a process of heat exchange between hot surfaces and the fluids in contact with them. Since most electronic devices or their parts are cooled by removing the heat generated inside them by using air as a heat transfer medium and in a free convection way, and the fact that heat transfer by free convection occurs in many fields, so there were many studies that dealt with this topic. The free load is generated by the buoyant force (Bouncy force) As a result of the difference in the density of the fluid adjacent to the heated surface due to the difference in temperatures between the fluid and the surface. The laminar flow along surfaces has been extensively studied analytically [1,2,3,4] In the horizontal, inclined and vertical case, whether by constant heat flux or constant surface temperature, there are also many experimental studies of heat transfer by free convection from horizontal, inclined and vertical surfaces with constant heat flux or constant surface temperature [5,6,7,8]. Some experimental studies have also been conducted on heat transfer by convection from heated surfaces in the form of a disk (ring)The outcome of these studies was to extract an exponential mathematical relationship between the average of Nusselt number and the Kirchhoff number or Rayleigh number and the following formula: (Nu=C(Ra) n It is one of the most suitable formulas for heat transfer by free convection from heated surfaces in all its forms and over a wide range of Rayleigh number . It is noted that not all of these studies dealt with the study of the effect of the cavity ratio on heat transfer by free convection from square-shaped surfaces, which is the form that is more applied in electronic devices. Therefore, the current research means studying the rate of change in the average of Nusselt number, which represents a function of the rate of change in the rate of heat transfer by convection, as well as studying the thermal gradient above the surface, and this was done through using three hollow surfaces in proportions (0.25,0.5,0.75) of the total area.


Author(s):  
P. A. Walsh ◽  
E. J. Walsh ◽  
Y. S. Muzychka

The problem of elevated heat flux in modern electronics has led to the development of numerous liquid cooling devices which yield superior heat transfer coefficients over their air based counterparts. This study investigates the use of liquid/gas slug flows where a liquid coolant is segregated into discrete slugs, resulting in a segmented flow, and heat transfer rates are enhanced by an internal circulation within slugs. This circulation directs cooler fluid from the center of the slug towards the heated surface and elevates the temperature difference at the wall. An experimental facility is built to examine this problem in circular tube flow with a constant wall heat flux boundary condition. This was attained by Joule heating a thin walled stainless steel tube. Water was used as the coolant and air as the segregating phase. The flow rates of each were controlled using high precision syringe pumps and a slug producing mechanism was introduced for segmenting the flow into slugs of various lengths at any particular flow rate. Tube flows with Reynolds numbers in the range 10 to 1500 were examined ensuring a well ordered segmented flow throughout. Heat transfer performance was calculated by measuring the exterior temperature of the thin tube wall at various locations using an Infrared camera. Nusselt number results are presented for inverse Graetz numbers over four decades, which spans both the thermally developing and developed regions. The results show that Nu in the early thermally developing region are slightly inferior to single phase flows for heat transfer performance but become far superior at higher values of inverse Gr. Additionally, the slug length plays an important role in maximizing Nusselt number in the fully developed region as Nu plateaus at different levels for slugs of differing lengths. Overall, this paper provides a new body of experimental findings relating to segmented flow heat transfer in constant heat flux tubes without boiling. Put abstract text here.


Author(s):  
Md. Faizan ◽  
Sukumar Pati ◽  
Pitamber R Randive

In this paper, the effect of non-uniform heating on the conjugate thermal and hydraulic characteristics for Al2O3–water nanofluid flow through a converging duct is examined numerically. An Eulerian–Lagrangian model is employed to simulate the two-phase flow for the following range of parameters: Reynolds number (100 ≤ Re ≤ 800), nanoparticle volume fraction (0% ≤  ϕ ≤ 5%) and amplitude of the sinusoidal heat flux ( A = 0, 0.5 and 1). The results reveal a similar affinity between the applied heat flux and local Nusselt number variation qualitatively, mainly at the middle of the duct. The results also indicate that there is a considerable enhancement of Nusselt number with the increase in Reynolds number and the thermal conductivity of wall materials. In addition, increasing the particle loading contributes to an enhanced rate of heat transfer. The heat transfer rate is lower for non-uniform heating when compared with the constant heat flux and the same can be compensated by the application of volume fraction of nanoparticles


Author(s):  
Z. X. Jia ◽  
G. Q. Xu ◽  
J. Wen ◽  
H. W. Deng

Experiments are performed to study the effect of surface coke deposition on heat transfer of aviation hydrocarbon RP-3 under supercritical pressure. The flowing RP-3 kerosene is stressed to 5MPa, and heated up to 130°C to 450°C in a stainless tube (1.8mm I.D., 2.2mm O.D., 1Cr18Ni9Ti) with a constant heat flux, and the mass flow rate is 3g/s. The working fluids flowed downwards through an 1800mm long tube. The experimental results indicated that insoluble products deposited onto metal surface have a significant impact on flow resistance and heat transfer the effect of coke deposition on heat transfer coefficient can be divided into four regimes: a) onset heat transfer enhancement zone; b) transition zone; c) heat transfer impairment zone; d) heat transfer stabilizing zone.


2012 ◽  
Author(s):  
Vedanth Srinivasan ◽  
Rok Kopun

In this paper, we discuss the implementation and testing of a novel boiling mass transfer model to simulate the thermal and phase transformation behavior, generated due to boiling of binary mixtures, using the commercial CFD code AVL FIRE® v2011. The phase change model, based on detailed bubble dynamics effects, is solved in conjunction with incompressible phasic momentum, turbulence and energy equations in a segregated fashion, to study the flow boiling process inside a rectangular duct. Full three dimensional validation studies including the effect of flow velocity and exit pressure conditions, acting on a wide range of operating wall (superheat) temperatures, clearly shows the suppression of heat and mass transfer coefficients with enhancement in flow convection. Competing mechanisms such as phase change process and turbulent convection are identified to influence the heat transfer characteristics. In particular, the varying influence of the mass transfer effects on the heat flux characteristics with alteration in wall temperature is well demonstrated. Comparisons of the predicted total heat flux, computed as the sum of the convection and phase change components, indicate a very good agreement with experimental data, wherever available. Description of the flow field inclusive of phasic fraction, temperature and velocity field provides extensive details of the multiphase behavior of the boiling flow. Some preliminary results on the phase change work flow to model heat transfer in cooling jackets, for automotive applications, is also discussed.