Modeling Dynamic Response of Hydraulic Fluid Within Tapered Transmission Lines

Author(s):  
Jeremy W. ven der Buhs ◽  
Travis K. Wiens

This paper examines modeling of the laminar dynamic fluid responses within hydraulic transmission lines that have a tapered shape between the inlet and the outlet. There are excellent models available for fast simulation of pressure and flow dynamics within uniform lines; however, the established models for tapered lines either cannot be implemented in the time domain, are complex to implement, or have long simulation times. The enhanced transmission line method (TLM) structure is applied in this paper since it can be computed quickly in the time domain and has shown to accurately model the effects of frequency-dependent friction. This paper presents a method of optimizing the TLM weighting functions, minimizing the error between the TLM transmission matrix terms and a numerical ordinary differential equation (ODE) solution calculated using a boundary value solver. Optimizations have shown that using the TLM to model tapered lines can provide a fair approximation when compared in the frequency domain. Two-dimensional (2D) interpolation of a look-up table is possible allowing for quick selection of the optimized parameters. Further investigation into the effects of pipe wall elasticity and its inclusion into the TLM is also performed. Also, an experiment was performed to validate high frequency harmonic peaks present in the frequency response, which yielded acceptable results when compared to the theory, and the proposed tapered TLM. This model can be used in numerous applications where line dynamic effects must be accounted for, especially with digital hydraulic switched inertance converters where high frequencies are present.

1988 ◽  
Vol 110 (1) ◽  
pp. 43-47 ◽  
Author(s):  
J. N. Brekke ◽  
T. N. Gardner

The avoidance of “slack” tethers is one of the factors which may establish the required tether pretension in a tension leg platform (TLP) design. Selection of an appropriate safety factor on loss of tension depends on how severe the consequences may be. It is sometimes argued that if tethers go slack, the result may be excessive platform pitch or roll motions, tether buckling, or “snap” or “snatch” loading of the tether. The results reported here show that a four-legged TLP would not be susceptible to larger angular motions until two adjacent legs lose tension simultaneously. Even then, this analysis shows that a brief period of tether tension loss (during the passage of a large wave trough) does not lead to excessive platform motion. Similarly, momentary tension loss does not cause large bending stress in the tether or significant tension amplification as the tether undergoes retensioning. This paper presents TLP platform and tether response analysis results for a representative deepwater Gulf of Mexico TLP with large-diameter, self-buoyant tethers. The time-domain, dynamic computer analysis included nonlinear effects and platform/tether coupling.


1982 ◽  
Vol 19 (4) ◽  
pp. 511-517 ◽  
Author(s):  
T. H. W. Baker ◽  
J. L. Davis ◽  
H. N. Hayhoe ◽  
G. C. Topp

The time-domain reflectometry technique was compared with the temperature measurement method for locating the frozen–unfrozen interface in water and sandy soils. This technique depends on the high-frequency (1–1000 MHz) electrical properties of water that change significantly and abruptly between the liquid and solid phases. Parallel wire transmission lines were inserted into the soil to guide electromagnetic pulses produced by a time-domain reflectometer (TDR). The frozen–unfrozen interface produced reflections measured by the TDR which were in turn used to locate the interface as it moved along the transmission line. In the laboratory it was possible to locate the interface using the TDR to within ±0.5 cm and in the field to within ±2.4 cm. These errors were equal to those associated with the temperature measurements. Keywords: soil freezing, temperature measurements, dielectric constant, time-domain reflectometry.


1983 ◽  
Vol 50 (2) ◽  
pp. 415-420 ◽  
Author(s):  
W. D. Iwan ◽  
C. M. Krousgrill

An approximate method is presented for determining the dynamical response of certain continuous nonlinear systems. In the proposed method, the system equation is linearized in the time domain prior to generation of a solution in the spatial domain. The approach is particularly suited to problems with complex boundary conditions which make selection of realistic global, spatial, domain comparison functions difficult. The approach is ideally suited to problems where discretization using finite elements is appropriate. The transverse response of a nonlinear rectangular plate is examined by way of the application of the proposed method.


Sign in / Sign up

Export Citation Format

Share Document