scholarly journals Contributions of Kinetic Energy and Viscous Dissipation to Airway Resistance in Pulmonary Inspiratory and Expiratory Airflows in Successive Symmetric Airway Models With Various Bifurcation Angles

2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Sanghun Choi ◽  
Jiwoong Choi ◽  
Ching-Long Lin

The aim of this study was to investigate and quantify contributions of kinetic energy and viscous dissipation to airway resistance during inspiration and expiration at various flow rates in airway models of different bifurcation angles. We employed symmetric airway models up to the 20th generation with the following five different bifurcation angles at a tracheal flow rate of 20 L/min: 15 deg, 25 deg, 35 deg, 45 deg, and 55 deg. Thus, a total of ten computational fluid dynamics (CFD) simulations for both inspiration and expiration were conducted. Furthermore, we performed additional four simulations with tracheal flow rate values of 10 and 40 L/min for a bifurcation angle of 35 deg to study the effect of flow rate on inspiration and expiration. Using an energy balance equation, we quantified contributions of the pressure drop associated with kinetic energy and viscous dissipation. Kinetic energy was found to be a key variable that explained the differences in airway resistance on inspiration and expiration. The total pressure drop and airway resistance were larger during expiration than inspiration, whereas wall shear stress and viscous dissipation were larger during inspiration than expiration. The dimensional analysis demonstrated that the coefficients of kinetic energy and viscous dissipation were strongly correlated with generation number. In addition, the viscous dissipation coefficient was significantly correlated with bifurcation angle and tracheal flow rate. We performed multiple linear regressions to determine the coefficients of kinetic energy and viscous dissipation, which could be utilized to better estimate the pressure drop in broader ranges of successive bifurcation structures.

Water ◽  
2021 ◽  
Vol 13 (16) ◽  
pp. 2179
Author(s):  
Jonathan Graciano-Uribe ◽  
Toni Pujol ◽  
Jaume Puig-Bargués ◽  
Miquel Duran-Ros ◽  
Gerard Arbat ◽  
...  

The small open area available at the slots of underdrains in pressurized granular bed filters for drip irrigation implies: (1) the existence of a region with non-uniform flow, and (2) local values of modified particle Reynolds number >500. These flow conditions may disagree with those accepted as valid for common pressure drop-flow rate correlations proposed for packed beds. Here, we carried out detailed computational fluid dynamics (CFD) simulations of a laboratory filter to analyze the results obtained with five different equations of head losses in porous media: (1) Ergun, (2) Darcy-Forchheimer, (3) Darcy, (4) Kozeny-Carman and (5) power function. Simulations were compared with experimental data at different superficial velocities obtained from previous studies. Results for two silica sand media indicated that all equations predicted total filter pressure drop values within the experimental uncertainty range when superficial velocities <38.3 m h−1. At higher flow rates, Ergun equation approximated the best to the observed results for silica sand media, being the expression recommended. A simple analytical model of the pressure drop along flow streamlines that matched CFD simulation results was developed.


2000 ◽  
Author(s):  
Snezana Konecni ◽  
Nathan K. Bultman

Abstract Water flow in cooling channels was simulated using the computational fluid dynamics (CFD) code CFX4. Pressure drop in the cooling channels of the coupled-cavity linac (CCL) cavity was calculated. The effects of the manifold on the pressure drop were studied also. Reducing the pressure drop was a primary goal of this exercise that led to changing the cooling channel entrance regions. Results of this analysis were used in sizing pumps required for the cooling system. For the validation of the simplified numerical model, an experiment was performed to measure the pressure drop in the cooling channels for variable flow rate, using a flow loop. Deionized water was circulated through the test section with a pump and its flow rate was monitored with a turbine flow meter. Pressure was monitored with pressure transducers at five locations including a differential pressure transducer across the test section, and water temperature was taken at the exit of the pump. Pressure drop across the inlet and outlet of the test section was measured and recorded for different flow rates. Flow rate was also monitored and stored simultaneously. From the recorded data, an empirical correlation was derived to describe the pressure drop, dp, as a function of flow rate through the four cooling channels.


1989 ◽  
Vol 199 ◽  
pp. 563-568 ◽  
Author(s):  
S. M. Richardson

It is well-known that laminar flow of a liquid in a duct is predicted to choke if the viscosity of the liquid increases exponentially with increasing pressure. In other words, the pressure drop in the duct is predicted to become unbounded when the volumetric flow rate reaches a critical finite value. Choking is not observed in practice, however: the reason why is investigated here. It is shown that choking is always predicted to occur if the viscosity is independent of temperature or heat generation by viscous dissipation is neglected. If the viscosity decreases exponentially with increasing temperature and heat generation is not neglected, however, and if the temperature field is fully developed or if the flow is adiabatic, it is shown that choking is predicted not to occur.


Author(s):  
Murthy Lakshmiraju ◽  
Jie Cui ◽  
Stephen Idem ◽  
Sastry Munukutla

As governmental regulations on the emission of the power industry became more restrictive, many power plants operating today experience severe problems. The fans that handle the flow through the stack, that were originally designed to handle a certain maximum flow rate, are now required to handle even higher flow rates due to the introduction of emission control devices. In this study, computational fluid dynamics (CFD) and experimental studies have been carried out on the scale model of a stack to identify means for pressure drop reduction. The CFD model was constructed using the commercial software CFX-5.6. The model solves the Reynolds averaged Navier-Stokes equation with Shear-Stress turbulence model (SST) and the CFD results are validated by data taken from the scale model. Baffles of different orientation have been installed in the stack under different flow conditions. Both numerical and experimental results confirm that adding baffles can reduce the pressure drop in a stack significantly. Thus, with minimum effort, power plants can keep running the stacks at a higher flow rate.


2019 ◽  
Vol 7 (1) ◽  
pp. 1
Author(s):  
Novi Sylvia ◽  
Anisa Anisa ◽  
Lukman Hakim

To increasing the heating value of biogas and natural gas on  industry needed a way to separate the carbon dioxide (CO2) use technology absorption. Many methods have been used to absorb the CO2 that has been researched, but most still use the absorption process in batch system. Therefore, this research will be conducted on the process of absorption of carbon dioxide (CO2) and water (H2O) will be simulated using Computational Fluid Dynamic (CFD). This research aims to test the performance of column absorption absorption on the process of carbon dioxide (CO2) and uses Autodesk Inventor  2016 and Fluent 16.0 to model the absorption and the pressure drop on the absorption column. This research was conducted with varying influence of the flow rate of water and carbon dioxide by comparison 2:1, i.e. CO2 117.75; 141.3 ;188.4 liters/min  and  H2O 235.5; 282.6 and 376.8 liters/minute.The results obtained show that the Percent of the maximum absorption i.e. 45.89% of flow rate of CO2 occurs at 117.75 liters/minute and H2O at 235.5 litres/minute, while the percent the minimum absorption i.e. 28.32% occurred at a flow rate of CO2 188.4 liters/minute and H2O 376.8 liters/minute. The highest pressure drop occurs at 188.4 liters/minute flow rate of CO2 and H2O 376.8 liters/minute, with a value of ∆P 0.66 atm, while the lowest pressure drop occurs at 177.75 liters/minute of CO2 and H2O at 235.5 litres/minute with the value of ∆P 0.17 atm.Key words:    absorption, water, Computational Fluid Dynamic, carbon dioxide, pressure drop


2018 ◽  
Vol 13 (3) ◽  
pp. 1-10 ◽  
Author(s):  
I.Sh. Nasibullayev ◽  
E.Sh Nasibullaeva ◽  
O.V. Darintsev

The flow of a liquid through a tube deformed by a piezoelectric cell under a harmonic law is studied in this paper. Linear deformations are compared for the Dirichlet and Neumann boundary conditions on the contact surface of the tube and piezoelectric element. The flow of fluid through a deformed channel for two flow regimes is investigated: in a tube with one closed end due to deformation of the tube; for a tube with two open ends due to deformation of the tube and the differential pressure applied to the channel. The flow rate of the liquid is calculated as a function of the frequency of the deformations, the pressure drop and the physical parameters of the liquid.


2021 ◽  
Vol 11 (4) ◽  
pp. 520
Author(s):  
Emily R. Nordahl ◽  
Susheil Uthamaraj ◽  
Kendall D. Dennis ◽  
Alena Sejkorová ◽  
Aleš Hejčl ◽  
...  

Computational fluid dynamics (CFD) has grown as a tool to help understand the hemodynamic properties related to the rupture of cerebral aneurysms. Few of these studies deal specifically with aneurysm growth and most only use a single time instance within the aneurysm growth history. The present retrospective study investigated four patient-specific aneurysms, once at initial diagnosis and then at follow-up, to analyze hemodynamic and morphological changes. Aneurysm geometries were segmented via the medical image processing software Mimics. The geometries were meshed and a computational fluid dynamics (CFD) analysis was performed using ANSYS. Results showed that major geometry bulk growth occurred in areas of low wall shear stress (WSS). Wall shape remodeling near neck impingement regions occurred in areas with large gradients of WSS and oscillatory shear index. This study found that growth occurred in areas where low WSS was accompanied by high velocity gradients between the aneurysm wall and large swirling flow structures. A new finding was that all cases showed an increase in kinetic energy from the first time point to the second, and this change in kinetic energy seems correlated to the change in aneurysm volume.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Antoine Riaud ◽  
Cui Wang ◽  
Jia Zhou ◽  
Wanghuai Xu ◽  
Zuankai Wang

AbstractElectric energy generation from falling droplets has seen a hundred-fold rise in efficiency over the past few years. However, even these newest devices can only extract a small portion of the droplet energy. In this paper, we theoretically investigate the contributions of hydrodynamic and electric losses in limiting the efficiency of droplet electricity generators (DEG). We restrict our analysis to cases where the droplet contacts the electrode at maximum spread, which was observed to maximize the DEG efficiency. Herein, the electro-mechanical energy conversion occurs during the recoil that immediately follows droplet impact. We then identify three limits on existing droplet electric generators: (i) the impingement velocity is limited in order to maintain the droplet integrity; (ii) much of droplet mechanical energy is squandered in overcoming viscous shear force with the substrate; (iii) insufficient electrical charge of the substrate. Of all these effects, we found that up to 83% of the total energy available was lost by viscous dissipation during spreading. Minimizing this loss by using cascaded DEG devices to reduce the droplet kinetic energy may increase future devices efficiency beyond 10%.