Boundary Layer Flashback in Premixed Hydrogen–Air Flames With Acoustic Excitation

Author(s):  
Vera Hoferichter ◽  
Thomas Sattelmayer

Lean premixed combustion is prevailing in gas turbines to minimize nitrogen oxide emissions. However, this technology bears the risk of flame flashback and thermoacoustic instabilities. Thermoacoustic instabilities induce velocity oscillations at the burner exit which, in turn, can trigger flame flashback. This article presents an experimental study at ambient conditions on the effect of longitudinal acoustic excitation on flashback in the boundary layer of a channel burner. The acoustic excitation simulates the effect of thermoacoustic instabilities. Flashback limits are determined for different excitation frequencies characterizing intermediate frequency dynamics in typical gas turbine combustors (100–350 Hz). The excitation amplitude is varied from 0% to 36% of the burner bulk flow velocity. For increasing excitation amplitude, the risk of flame flashback increases. This effect is strongest at low frequencies. For increasing excitation frequency, the influence of the velocity oscillations decreases as the flame has less time to follow the changes in bulk flow velocity. Two different flashback regimes can be distinguished based on excitation amplitude. For low excitation amplitudes, flashback conditions are reached if the minimum flow velocity in the excitation cycle falls below the flashback limit of unexcited unconfined flames. For higher excitation amplitudes, where the flame starts to periodically enter the burner duct, flashback is initiated if the maximum flow velocity in the excitation cycle is lower than the flashback limit of confined flames. Consequently, flashback limits of confined flames should also be considered in the design of gas turbine burners as a worst case scenario.

Author(s):  
Vera Hoferichter ◽  
Thomas Sattelmayer

Lean premixed combustion is prevailing in gas turbines to minimize nitrogen oxide emissions. However, this technology bears the risk of flame flashback and thermoacoustic instabilities. Thermoacoustic instabilities induce velocity oscillations at the burner exit which, in turn, can trigger flame flashback. This article presents an experimental study at ambient conditions on the effect of longitudinal acoustic excitation on flashback in the boundary layer of a channel burner. The acoustic excitation simulates the effect of thermoacoustic instabilities. Flashback limits are determined for different excitation frequencies characterizing intermediate frequency dynamics in typical gas turbine combustors (100–350 Hz). The excitation amplitude is varied from 0 to 36 % of the burner bulk flow velocity. For increasing excitation amplitude, the risk of flame flashback increases. This effect is strongest at low frequencies. For increasing excitation frequency the influence of the velocity oscillations decreases as the flame has less time to follow the changes in bulk flow velocity. Two different flashback regimes can be distinguished based on excitation amplitude. For low excitation amplitudes flashback conditions are reached if the minimum flow velocity in the excitation cycle falls below the flashback limit of unexcited unconfined flames. For higher excitation amplitudes, where the flame starts to periodically enter the burner duct, flashback is initiated if the maximum flow velocity in the excitation cycle is lower than the flashback limit of confined flames. Consequently, flashback limits of confined flames should also be considered in the design of gas turbine burners as a worst case scenario.


Author(s):  
Dominik Ebi ◽  
Peter Jansohn

Abstract Operating stationary gas turbines on hydrogen-rich fuels offers a pathway to significantly reduce greenhouse gas emissions in the power generation sector. A key challenge in the design of lean-premixed burners, which are flexible in terms of the amount of hydrogen in the fuel across a wide range and still adhere to the required emissions levels, is to prevent flame flashback. However, systematic investigations on flashback at gas turbine relevant conditions to support combustor development are sparse. The current work addresses the need for an improved understanding with an experimental study on boundary layer flashback in a generic swirl burner up to 7.5 bar and 300°C preheat temperature. Methane-hydrogen-air flames with 50 to 85% hydrogen by volume were investigated. Flashback limits are reported in terms of the equivalence ratio for a given pressure, preheat temperature, bulk flow velocity and hydrogen content. The wall temperature of the center body along which the flame propagated during flashback events has been controlled by an oil heating/cooling system. This way, the effect any of the control parameters, e.g. pressure, had on the flashback limit was de-coupled from the otherwise inherently associated change in heat load on the wall and thus change in wall temperature. The results show that the preheat temperature has a weaker effect on the flashback propensity than expected. Increasing the pressure from atmospheric conditions to 2.5 bar strongly increases the flashback risk, but hardly affects the flashback limit beyond 2.5 bar.


Entropy ◽  
2021 ◽  
Vol 23 (5) ◽  
pp. 567
Author(s):  
Xudong Jiang ◽  
Yihao Tang ◽  
Zhaohui Liu ◽  
Venkat Raman

When operating under lean fuel–air conditions, flame flashback is an operational safety issue in stationary gas turbines. In particular, with the increased use of hydrogen, the propagation of the flame through the boundary layers into the mixing section becomes feasible. Typically, these mixing regions are not designed to hold a high-temperature flame and can lead to catastrophic failure of the gas turbine. Flame flashback along the boundary layers is a competition between chemical reactions in a turbulent flow, where fuel and air are incompletely mixed, and heat loss to the wall that promotes flame quenching. The focus of this work is to develop a comprehensive simulation approach to model boundary layer flashback, accounting for fuel–air stratification and wall heat loss. A large eddy simulation (LES) based framework is used, along with a tabulation-based combustion model. Different approaches to tabulation and the effect of wall heat loss are studied. An experimental flashback configuration is used to understand the predictive accuracy of the models. It is shown that diffusion-flame-based tabulation methods are better suited due to the flashback occurring in relatively low-strain and lean fuel–air mixtures. Further, the flashback is promoted by the formation of features such as flame tongues, which induce negative velocity separated boundary layer flow that promotes upstream flame motion. The wall heat loss alters the strength of these separated flows, which in turn affects the flashback propensity. Comparisons with experimental data for both non-reacting cases that quantify fuel–air mixing and reacting flashback cases are used to demonstrate predictive accuracy.


Author(s):  
Dominik Ebi ◽  
Peter Jansohn

Abstract Operating stationary gas turbines on hydrogen-rich fuels offers a pathway to significantly reduce greenhouse gas emissions in the power generation sector. A key challenge in the design of lean-premixed burners, which are flexible in terms of the amount of hydrogen in the fuel across a wide range and still adhere to the required emissions levels, is to prevent flame flashback. However, systematic investigations on flashback at gas turbine relevant conditions to support combustor development are sparse. The current work addresses the need for an improved understanding with an experimental study on boundary layer flashback in a generic swirl burner up to 7.5 bar and 300° C preheat temperature. Methane-hydrogen-air flames with 50 to 85% hydrogen by volume were investigated. High-speed imaging was applied to reveal the flame propagation pathway during flashback events. Flashback limits are reported in terms of the equivalence ratio for a given pressure, preheat temperature, bulk flow velocity and hydrogen content. The wall temperature of the center body along which the flame propagated during flashback events has been controlled by an oil heating/cooling system. This way, the effect any of the control parameters, e.g. pressure, had on the flashback limit was de-coupled from the otherwise inherently associated change in heat load on the wall and thus change in wall temperature. The results show that the preheat temperature has a weaker effect on the flashback propensity than expected. Increasing the pressure from atmospheric conditions to 2.5 bar strongly increases the flashback risk, but hardly affects the flashback limit beyond 2.5 bar.


Author(s):  
Christian Felsmann ◽  
Uwe Gampe ◽  
Manfred Freimark

Solar hybrid gas turbine technology has the potential to increase the efficiency of future solar thermal power plants by utilizing solar heat at a much higher temperature level than state of the art plants based on steam turbine cycles. In a previous paper the authors pointed out, that further development steps are required for example in the field of component development and in the investigation of the system dynamics to realize a mature technology for commercial application [1]. In this paper new findings on system dynamics are presented based on the simulation model of a solar hybrid gas turbine with parallel arrangement of the combustion chamber and solar receivers. The operational behavior of the system is described by means of two different scenarios. The System operation in a stand-alone electrical supply network is investigated in the first scenario. Here it is shown that fast load changes in the network lead to a higher shaft speed deviation of the electric generator compared to pure fossil fired systems. In the second scenario a generator load rejection, as a worst case, is analyzed. The results make clear that additional relief concepts like blow-off valves are necessary as the standard gas turbine protection does not meet the specific requirements of the solar hybrid operation. In general the results show, that the solar hybrid operational modes are much more challenging for the gas turbines control and safety system compared to pure fossil fired plants due to the increased volumetric storage capacity of the system.


Author(s):  
Alireza Kalantari ◽  
Nicolas Auwaijan ◽  
Vincent McDonell

Abstract Lean-premixed combustion is commonly used in gas turbines to achieve low pollutant emissions, in particular nitrogen oxides. But use of hydrogen-rich fuels in premixed systems can potentially lead to flashback. Adding significant amounts of hydrogen to fuel mixtures substantially impacts the operating range of the combustor. Hence, to incorporate high hydrogen content fuels into gas turbine power generation systems, flashback limits need to be determined at relevant conditions. The present work compares two boundary layer flashback prediction methods developed for turbulent premixed jet flames. The Damköhler model was developed at University of California Irvine (UCI) and evaluated against flashback data from literature including actual engines. The second model was developed at Paul Scherrer Institut (PSI) using data obtained at gas turbine premixer conditions and is based on turbulent flame speed. Despite different overall approaches used, both models characterize flashback in terms of similar parameters. The Damköhler model takes into account the effect of thermal coupling and predicts flashback limits within a reasonable range. But the turbulent flame speed model provides a good agreement for a cooled burner, but shows less agreement for uncooled burner conditions. The impact of hydrogen addition (0 to 100% by volume) to methane or carbon monoxide is also investigated at different operating conditions and flashback prediction trends are consistent with the existing data at atmospheric pressure.


Author(s):  
Vera Hoferichter ◽  
Payam Mohammadzadeh Keleshtery ◽  
Christoph Hirsch ◽  
Thomas Sattelmayer ◽  
Yoshikazu Matsumura

Alternative fuels like hydrogen are presently discussed as one possibility to reduce carbon dioxide emissions from gas turbines. Premixed lean combustion is a current standard to minimize nitrogen oxide emissions. However, the early mixing of fuel and oxidizer upstream of the combustion chamber opens up the possibility of upstream flame propagation, referred to as flame flashback. Flame flashback in gas turbines has to be prevented as it leads to immediate engine shut down or even structural damage. Due to high burning velocities and low quenching distances, flashback is especially critical in premixed hydrogen flames. In particular, the low velocity region near the burner wall promotes flashback. Diluting the mixture near the wall by fluid injection is one approach to counteract this phenomenon and to enhance the safe operating range of a gas turbine burner. This article presents an experimental study on the effect of air injection on flame flashback investigated at a channel burner configuration. Different injection mass flow rates, positions and angles are compared to a reference case without injection regarding their flashback limits. The effectiveness of the injection increases with the injected mass flow rate. The resulting flashback limits can be correlated with the equivalence ratio at the wall by concepts taken from film cooling. However, the fluid injector is a source of boundary layer disturbances leading to an initial penalty regarding flashback resistance. This penalty increases the closer the injector is located to the burner exit. Furthermore, the penalty increases for lower injection angles as the area of the injector and the corresponding boundary layer disturbances increase.


Author(s):  
Stefan Bauer ◽  
Balbina Hampel ◽  
Thomas Sattelmayer

Abstract Vortex generators are known to be effective in augmenting the mixing of fuel jets with air. The configuration investigated in this study is a tubular air passage with fuel injection from one single orifice placed in the side wall. In the range of typical gas turbine combustor inlet temperatures, the performance vortex generator premixers (VGPs) have already been investigated for natural gas as well as for blends of natural gas and hydrogen. However, for highly reactive fuels, the application of VGPs in recuperated gas turbines is particularly challenging because the high combustor inlet temperature leads to potential risk with regard to premature self-ignition and flame flashback. As the current knowledge does not cover the temperature range far above the self-ignition temperature, an experimental investigation of the operational limits of VGPs is currently being conducted at the Thermodynamics Institute of the Technical University of Munich, Garching, Germany, which is particularly focused on reactive fuels and the thermodynamic conditions present in recuperated gas turbines with pressure ratios of 4–5. For the study presented in this paper, an atmospheric combustion VGP test rig has been designed, which facilitates investigations in a wide range of operating conditions in order to comply with the situation in recuperated microgas turbines (MGT), namely, global equivalence ratios between 0.2 and 0.7, air preheating temperatures between 288 K and 1100 K, and air bulk flow rates between 6 and 16 g/s. Both the entire mixing zone in the VGP and the primary combustion zone of the test rig are optically accessible. High-speed OH* chemiluminescence imaging is used for the detection of the flashback and blow-off limits of the investigated VGPs. Flashback and blow-off limits of hydrogen in a wide temperature range covering the autoignition regime are presented, addressing the influences of equivalence ratio, air preheating temperature, and momentum ratio between air and hydrogen on the operational limits in terms of bulk flow velocity. It is shown that flashback and blow-off limits are increasingly influenced by autoignition in the ultrahigh temperature regime.


Author(s):  
Peter T. McGuigan

Contaminants are ever-present in the air. Contaminated air entering a Gas Turbine will damage internal components and bring about a reduction in overall efficiency. The amount of contaminant entering a Gas Turbine, therefore, needs to be minimised. This paper describes recent developments in the understanding of one such contaminant, salt. It describes how salt is produced, how it varies climatically and how it varies from location to location and is presented here in the context of the author’s particular field of competence — air filtration system design. Salt ingestion by a Gas Turbine intake can cause corrosion and, given time, can accumulate on the compressor blades and reduce the aerodynamic efficiency. The removal of salt in the air is therefore of primary concern to all those involved in the design and operation of Gas Turbines. Salt removal systems are manufactured in various guises. The concept, however, remains the same — salt capture upstream of the Compressor stage. The drawback to this method of salt removal is that it results in a decrease in air pressure entering the Compressor and will consequently bring about a decrease in the overall system performance. As the requirement to remove more and more salt contaminant increases, the pressure drop across the method of filtration required to achieve this, increases. The responsibility of the Filtration Engineer is therefore to fully understand the requirements of the Gas Turbine, to understand the balance between pressure drop, salt removal and salt size and, consequently, to design an appropriate filtration system — one fit for purpose. Gas Turbines in the marine environment are generally found at heights less than 50m above sea level. It is this environment (the Marine Boundary Layer) which historically has been difficult to fully quantify. Herein lies the problem for those involved — if the environment is not fully understood how can the proper exploitation of the technologies be achieved? Recent developments, however, have led to a better understanding of salt in the Marine Boundary Layer. This paper describes these recent developments.


Author(s):  
Marco Mastrovito ◽  
Antonio Ferrante ◽  
Sergio M. Camporeale ◽  
Federico Bonzani ◽  
Rosanna Ninni

Modern gas turbines are prone to trigger and sustain pressure oscillations induced by heat release in their combustor; these oscillations, called humming, can cause severe damage on the machine structure, or, on a less detrimental level, can limit gas turbine performance from load point of view or NOx emissions, increasing their concentration in flue gas. Thermoacoustic oscillation problem, although deeply investigated during the last 15 years, is far from being solved, so that both theoretical and experimental approaches are being used in order to improve basic knowledge of this phenomenon. With this aim an optoelectronic detector based system has been developed to be installed on a 270MW gas turbine to detect radiative energy release fluctuations due to thermoacoustic oscillations. This optoelectronic device has been used in combination with standard piezoelectric sensors with the target to get a better insight of the humming phenomenon. A data analysis method based on well established data processing techniques has been applied to data gathered from the field. The ensemble of data processing techniques seems to offer a method to evaluate the actual risk of thermoacoustic instabilities. This is the very first application of the proposed tool, and a long way has to be run before it is assessed as a prognostic device. Nevertheless in the h.o. of the authors, this first application encourages the continuation of developing the tool extending the base of monitored plants.