Production Cost–Efficiency Relation for Room Air Conditioners and Its Economic and Environmental Impact

2017 ◽  
Vol 139 (6) ◽  
Author(s):  
Esmail M. A. Mokheimer ◽  
Syed Hussain ◽  
Magd DinAli Nadeem ◽  
Ahmed Ali Mahmoud Abdulrahman

A large amount of the operating costs in a building is determined by the energy requirements of its air conditioning system. The demand for more energy efficient units desired by both manufacturers and the consumers results in a dire necessity to have air conditioning units that are more energy efficient than the existing ones. In order to achieve the abovementioned features, a tool must be designed to simulate the thermal behavior of the air conditioners. In this work, a mathematical model is developed for air conditioning units and coded into a computer program to estimate the overall performance, as indicated by the unit energy efficiency ratio (EER). The main objective is to maximize the unit EER by proposing modifications or enhancements in the existing unit and to study the economics of these modifications based on the measured terms such as the energy savings and the operating cost. Finally, the effect of the proposed design modifications on the economy and environment at the national level in Saudi Arabia is estimated and presented as an example.

2011 ◽  
Vol 280 ◽  
pp. 71-75
Author(s):  
Zhong Chao Zhao ◽  
Dong Hui Zhang ◽  
Yu Ping Chen

In this paper, the operation mechanism of combined air-conditioning system with temperature and humidity decoupled treatment (CACSTHDT) was presented, and the energy saving potential and economics of CACSTHDT were primarily analyzed through compared with a traditional air-conditioning system. The results indicated that CACSTHDT could save up to 28.64% energy consumption in comparison with a traditional air-conditioning system. The operating cost in one summer only was 71.36% of that cost of traditional air-conditioning system.


2014 ◽  
Vol 699 ◽  
pp. 828-833 ◽  
Author(s):  
Sumeru ◽  
Markus ◽  
Farid Nasir Ani ◽  
Henry Nasution

Air conditioning system consumes approximately 50% of the total energy consumption of buildings. Split-type air conditioner is the most widely used in residential and commercial buildings. As a result, enhancement on the performance of the air conditioners will yield a significant energy savings. The use of ejector as an expansion device on the split-type air conditioners is one method to increase the system performance. Exergy analysis on a split-type air conditioner uses an ejector as an expansion device at room and outdoor temperatures of 24 °C and 34 °C, respectively, yielded the percentage of exergy reduction up to 40.6%. Also, the exergy losses on in the compressor had the highest impact on the performance improvement of the split-type air conditioner.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


2019 ◽  
Vol 111 ◽  
pp. 04042
Author(s):  
Nicolás Ablanque ◽  
Santiago Torras ◽  
Carles Oliet ◽  
Joaquim Rigola ◽  
Carlos-David Pérez-Segarra

The simulation of HVAC systems is a powerful tool to improve the energy efficiency in buildings. The modelling of such systems faces several obstacles due to both the physical phenomenology present and the numerical resolution difficulties. The present work is an attempt to develop a robust, fast, and accurate model for HVAC systems that can interact with the other relevant systems involved in buildings thermal management. The whole system model has been developed in the form of libraries under the Modelica language to exploit its advantageous characteristics: object-oriented programming, equationbased modelling, and handling of multi-physics. The global resolution is carried out dynamically so that not only steady-state predictions can be conducted but also control strategies can be studied over meaningful periods of time. This latter aspect is crucial for optimizing energy savings. The libraries include models for all the system individual components such as pumps, compressors or heat exchangers (operating with twophase flows and/or moist air) and also models assemblies to account for vapour compression units and liquid circuits. An illustrative example of an indirect air conditioning system is detailed in the present work in order to highlight the model potential.


2018 ◽  
Author(s):  
Hamad H. Almutairi ◽  
Abdulrahman Almutairi ◽  
Jaber H. Almutairi

Buildings account for significant energy consumption worldwide particularly in regions where energy patterns influenced primarily by weather. Air conditioning system became an essential evaluation factor during building design and construction. The level of curiosity about air conditioning system efficiency in terms of energy usage is increasing quickly. In Kuwait; which is a hot climate country; air conditioners account for 70% of total electrical power. Electricity in Kuwait is produced entirely by the non-renewable energy resources. This work aims to assess the potential electrical savings that could be acquired by reducing building’s façade area towards East-West directional orientation in Kuwait. For this purpose, a detached building model with uniform geometry; was simulated by Energy Plus Thermal Simulation Engine through its interface with DesignBuilder software. Two cases were developed for the analysis; both have the same simulation inputs. The only difference was the orientation of the facades. The results show a reduction of about 900 kWh cooling annually if the largest facades were positioned towards north and south. The obtained saving in annual basis is attributed to about 420 kWh electrical power. Equivalent CO2 emissions associated with the saved electrical energy from power plants in Kuwait were estimated. The resulted savings are promising for early decision making for prospective buildings to be built in future.


1998 ◽  
Vol 18 (5) ◽  
pp. 327-335 ◽  
Author(s):  
Adnan A. Kinsara ◽  
Omar M. Al-Rabghi ◽  
Moustafa M. Elsayed

Sign in / Sign up

Export Citation Format

Share Document