Acoustic Boundary Layer Attenuation in Ducts With Rigid and Elastic Walls Applied to Cochlear Mechanics

2017 ◽  
Vol 139 (10) ◽  
Author(s):  
Frank Böhnke ◽  
Sebastian Semmelbauer

The cochlea is the most important part of the hearing system, due to the fact that it transforms sound guided through air, bone, and lymphatic fluid to vibrations of the cochlear partition which includes the organ of Corti with its sensory cells. These send nerve impulses to the brain leading to hearing perception. The work presents the wave propagation in rigid ducts filled with air or water including viscous-thermal boundary layer damping. In extension, a mechanical box model of the human cochlea represented by a rectangular duct limited by the tapered basilar membrane at one side is developed and evaluated numerically by the finite element method. The results match with rare experiments on human temporal bones without using the physically unfounded assumption of Rayleigh damping. A forecast on the concept of the traveling wave parametric amplification is given to potentially explain the high hearing sensitivity and otoacoustic emissions.

1989 ◽  
Vol 98 (5_suppl) ◽  
pp. 23-34 ◽  
Author(s):  
Michele Roberto ◽  
Roger P. Hamernik ◽  
George A. Turrentine

This paper reviews the results of several studies on the effects of blast wave exposure on the auditory system of the chinchilla, the pig, and the sheep. The chinchillas were exposed at peak sound pressure levels of approximately 160 dB under well-controlled laboratory conditions. A modified shock tube was used to generate the blast waves. The pigs and sheep were exposed under field conditions in an instrumented hard-walled enclosure. Blast trauma was induced by the impact of a single explosive projectile. The peak sound pressure levels varied between 178 and 209 dB. All animals were killed immediately following exposure, and their temporal bones were removed for fixation and histologic analysis using light microscopy and scanning electron microscopy. Middle ears were examined visually for damage to the conductive system. There were well-defined differences in susceptibility to acoustic trauma among species. However, common findings in each species were the acute mechanical fracture and separation of the organ of Corti from the basilar membrane, and tympanic membrane and ossicular failure.


2005 ◽  
Vol 2 (4) ◽  
pp. 341-348 ◽  
Author(s):  
Hongxue Cai ◽  
Daphne Manoussaki ◽  
Richard Chadwick

The cochlea transduces sound-induced vibrations in the inner ear into electrical signals in the auditory nerve via complex fluid–structure interactions. The mammalian cochlea is a spiral-shaped organ, which is often uncoiled for cochlear modelling. In those few studies where coiling has been considered, the cochlear partition was often reduced to the basilar membrane only. Here, we extend our recently developed hybrid analytical/numerical micromechanics model to include curvature effects, which were previously ignored. We also use a realistic cross-section geometry, including the tectorial membrane and cellular structures of the organ of Corti, to model the apical and basal regions of a guinea-pig cochlea. We formulate the governing equations of the fluid and solid domains in a curvilinear coordinate system. The WKB perturbation method is used to treat the propagation of travelling waves along the coiled cochlear duct, and the O (1) system of the governing equations is solved in the transverse plane using finite-element analysis. We find that the curvature of the cochlear geometry has an important functional significance; at the apex, it greatly increases the shear gain of the cochlear partition, which is a measure of the bending efficiency of the outer hair cell stereocilia.


2020 ◽  
Author(s):  
C. Elliott Strimbu ◽  
Yi Wang ◽  
Elizabeth S. Olson

ABSTRACTThe mammalian hearing organ, the cochlea, contains an active amplifier to boost the vibrational response to low level sounds. Hallmarks of this active process are sharp location-dependent frequency tuning and compressive nonlinearity over a wide stimulus range. The amplifier relies on outer hair cell (OHC) generated forces driven in part by the endocochlear potential (EP), the ~ +80 mV potential maintained in scala media, generated by the stria vascularis. We transiently eliminated the EP in vivo by an intravenous injection of furosemide and measured the vibrations of different layers in the cochlea’s organ of Corti using optical coherence tomography. Distortion product otoacoustic emissions (DPOAE) were monitored at the same times. Following the injection, the vibrations of the basilar membrane lost the best frequency (BF) peak and showed broad tuning similar to a passive cochlea. The intra-organ of Corti vibrations measured in the region of the OHCs lost their BF peak and showed low-pass responses, but retained nonlinearity, indicating that OHC electromotility was still operational. Thus, while electromotility is presumably necessary for amplification, its presence is not sufficient for amplification. The BF peak recovered nearly fully within 2 hours, along with a non-monotonic DPOAE recovery that suggests that physical shifts in operating condition are a final step in the recovery process.SIGNIFICANCEThe endocochlear potential, the +80 mV potential difference across the fluid filled compartments of the cochlea, is essential for normal mechanoelectrical transduction, which leads to receptor potentials in the sensory hair cells when they vibrate in response to sound. Intracochlear vibrations are boosted tremendously by an active nonlinear feedback process that endows the cochlea with its healthy sensitivity and frequency resolution. When the endocochlear potential was reduced by an injection of furosemide, the basilar membrane vibrations resembled those of a passive cochlea, with broad tuning and linear scaling. The vibrations in the region of the outer hair cells also lost the tuned peak, but retained nonlinearity at frequencies below the peak, and these sub-BF responses recovered fairly rapidly. Vibration responses at the peak recovered nearly fully over 2 hours. The staged vibration recovery and a similarly staged DPOAE recovery suggests that physical shifts in operating condition are a final step in the process of cochlear recovery.


2019 ◽  
Vol 116 (28) ◽  
pp. 13977-13982 ◽  
Author(s):  
Stefan Raufer ◽  
John J. Guinan ◽  
Hideko Heidi Nakajima

Mammals detect sound through mechanosensitive cells of the cochlear organ of Corti that rest on the basilar membrane (BM). Motions of the BM and organ of Corti have been studied at the cochlear base in various laboratory animals, and the assumption has been that the cochleas of all mammals work similarly. In the classic view, the BM attaches to a stationary osseous spiral lamina (OSL), the tectorial membrane (TM) attaches to the limbus above the stationary OSL, and the BM is the major moving element, with a peak displacement near its center. Here, we measured the motion and studied the anatomy of the human cochlear partition (CP) at the cochlear base of fresh human cadaveric specimens. Unlike the classic view, we identified a soft-tissue structure between the BM and OSL in humans, which we name the CP “bridge.” We measured CP transverse motion in humans and found that the OSL moved like a plate hinged near the modiolus, with motion increasing from the modiolus to the bridge. The bridge moved almost as much as the BM, with the maximum CP motion near the bridge–BM connection. BM motion accounts for 100% of CP volume displacement in the classic view, but accounts for only 27 to 43% in the base of humans. In humans, the TM–limbus attachment is above the moving bridge, not above a fixed structure. These results challenge long-held assumptions about cochlear mechanics in humans. In addition, animal apical anatomy (inSI Appendix) doesn’t always fit the classic view.


1983 ◽  
Vol 76 (4) ◽  
pp. 269-278 ◽  
Author(s):  
A Wright

The human cochlea has been preserved from post-mortem autolysis by perfusion with a fixative shortly after death. Subsequent staining with osmium permits dissection of this structure from the temporal bone. (Temporal bones were obtained from eight patients). When prepared for examination in the scanning electron microscope, the auditory sensory cells are found to be located in the band-like organ of Corti which extends the length of the cochlea. The sensory cells have a cluster of stereocilia projecting from their free upper surface and because of this are called hair cells. The hair cells are divided into two separate groups: a single row of inner hair cells, which show little variation in their surface appearance along the length of the cochlea, and three or four rows of outer hair cells whose cilia change in conformation and increase in length along the cochlea.


2003 ◽  
Vol 90 (1) ◽  
pp. 444-455 ◽  
Author(s):  
Jiefu Zheng ◽  
Chunfu Dai ◽  
Peter S. Steyger ◽  
Youngki Kim ◽  
Zoltan Vass ◽  
...  

Capsaicin, the vanilloid that selectively activates vanilloid receptors (VRs) on sensory neurons for noxious perception, has been reported to increase cochlear blood flow (CBF). VR-related receptors have also been found in the inner ear. This study aims to address the question as to whether VRs exist in the organ of Corti and play a role in cochlear physiology. Capsaicin or the more potent VR agonist, resiniferatoxin (RTX), was infused into the scala tympani of guinea pig cochlea, and their effects on cochlear sensitivity were investigated. Capsaicin (20 μM) elevated the threshold of auditory nerve compound action potential and reduced the magnitude of cochlear microphonic and electrically evoked otoacoustic emissions. These effects were reversible and could be blocked by a competitive antagonist, capsazepine. Application of 2 μM RTX resulted in cochlear sensitivity alterations similar to that by capsaicin, which could also be blocked by capsazepine. A desensitization phenomenon was observed in the case of prolonged perfusion with either capsaicin or RTX. Brief increase of CBF by capsaicin was confirmed, and the endocochlear potential was not decreased. Basilar membrane velocity (BM) growth functions near the best frequency and BM tuning were altered by capsaicin. Immunohistochemistry study revealed the presence of vanilloid receptor type 1 of the transient receptor potential channel family in the hair cells and supporting cells of the organ of Corti and the spiral ganglion cells of the cochlea. The results indicate that the main action of capsaicin is on outer hair cells and suggest that VRs in the cochlea play a role in cochlear homeostasis.


1993 ◽  
Vol 107 (10) ◽  
pp. 883-891 ◽  
Author(s):  
G. Rossi ◽  
R. Actis ◽  
P. Solero ◽  
M. Rolando ◽  
M. D. Pejrone

AbstractFollowing stimulation of one ear with white noise (WN) or 0.5, 1 and 2 kHz tone bursts a statistically valid mean reduction in the amplitude of delayed evoked otoacoustic emissions (DEOE), elicited from the contralateral ear by bursts of the same frequencies, was observed in 10 people (19–23-years-old) with normal hearing. This reduction only appeared in response to a contralateral stimulus delivered 7, 8 and 9 ms earlier than that used to produce the DEOE. This inhibitory effect was just referable to the activity of the medial olivocochlear efferent system (MOES). This research has shown that: (i) the cochlear interdependence is linked to activation of the MOES; (ii) in man the activity of MOES is inhibitory and only appears for a stimulus of the same frequency or (for WN) including that used to elicit DEOE; (iii) the cochlear interdependence is frequency selective and the MOES thus establishes a direct functional interdependence between homologous sectors of the organs of Corti on the two sides; (iv) DEOE would appear to be no more than partly generated by outer hair cells (OHC) of the organ of Corti in relation to the frequency of the stimulus employed, thus substantiating the hypothesis that in their production the effects of an 'active' mechanism, represented by the 'slow' contractile activity of the OHC, is overlain by those of a 'passive' mechanism formed by the oscillations induced by the movements of the stapes in the basilar membrane (BM) or in the set of membranes and liquids of cochlear canal.


2018 ◽  
Author(s):  
A. Zosuls ◽  
L. C. Rupprecht ◽  
D. C. Mountain

AbstractThe presence of forward and reverse traveling wave modes on the basilar membrane has important implications to how the cochlea functions as a filter, transducer, and amplifier of sound. The presence and parameters of traveling waves are of particular importance to interpreting otoacoustic emissions (OAE). OAE are vibrations that propagate out of the cochlea and are measureable as sounds emitted from the tympanic membrane. The interpretation of OAE is a powerful research and clinical diagnostic tool, but OAE use has not reached full potential because the mechanisms of their generation and propagation are not fully understood. Of particular interest and deliberation is whether the emissions propagate as a fluid compression wave or a structural traveling wave. In this study a mechanical probe was used to simulate an OAE generation site and optical imaging was used to measure displacement of the inner hair cell stereocilia of the gerbil cochlea. Inner hair cell stereocilia displacement measurements were made in the radial dimension as a function of their longitudinal location along the length of the basilar membrane in response to a transverse stimulation from the probe. The analysis of the spatial frequency response of the inner hair cell stereocilia at frequencies near the characteristic frequency (CF) of the measurement location suggests that a traveling wave propagates in the cochlear partition simultaneously basal and apical (forward and reverse) from the probe location. The traveling wave velocity was estimated to be 5.9m/s - 8m/s in the base (near CF of 29kHz - 40kHz) and 1.9m/s - 2.4m/s in the second turn (near CF of 2kHz - 3kHz). These results suggest that the cochlear partition is capable of supporting both forward and reverse traveling wave modes generated by a source driving the basilar membrane. This suggests that traveling waves in the cochlear partition contribute to OAE propagation.


Author(s):  
R.J. Mount ◽  
R.V. Harrison

The sensory end organ of the ear, the organ of Corti, rests on a thin basilar membrane which lies between the bone of the central modiolus and the bony wall of the cochlea. In vivo, the organ of Corti is protected by the bony wall which totally surrounds it. In order to examine the sensory epithelium by scanning electron microscopy it is necessary to dissect away the protective bone and expose the region of interest (Fig. 1). This leaves the fragile organ of Corti susceptible to physical damage during subsequent handling. In our laboratory cochlear specimens, after dissection, are routinely prepared by the O-T- O-T-O technique, critical point dried and then lightly sputter coated with gold. This processing involves considerable specimen handling including several hours on a rotator during which the organ of Corti is at risk of being physically damaged. The following procedure uses low cost, readily available materials to hold the specimen during processing ,preventing physical damage while allowing an unhindered exchange of fluids.Following fixation, the cochlea is dehydrated to 70% ethanol then dissected under ethanol to prevent air drying. The holder is prepared by punching a hole in the flexible snap cap of a Wheaton vial with a paper hole punch. A small amount of two component epoxy putty is well mixed then pushed through the hole in the cap. The putty on the inner cap is formed into a “cup” to hold the specimen (Fig. 2), the putty on the outside is smoothed into a “button” to give good attachment even when the cap is flexed during handling (Fig. 3). The cap is submerged in the 70% ethanol, the bone at the base of the cochlea is seated into the cup and the sides of the cup squeezed with forceps to grip it (Fig.4). Several types of epoxy putty have been tried, most are either soluble in ethanol to some degree or do not set in ethanol. The only putty we find successful is “DUROtm MASTERMENDtm Epoxy Extra Strength Ribbon” (Loctite Corp., Cleveland, Ohio), this is a blue and yellow ribbon which is kneaded to form a green putty, it is available at many hardware stores.


Sign in / Sign up

Export Citation Format

Share Document