Experimental Study of Load Variations on Pressure Fluctuations in a Prototype Reversible Pump Turbine in Generating Mode

2017 ◽  
Vol 139 (7) ◽  
Author(s):  
Yuning Zhang ◽  
Ting Chen ◽  
Jinwei Li ◽  
Jixing Yu

The characteristics of pressure fluctuations in a prototype reversible pump turbine (RPT) is investigated within a wide range of load conditions with a focus on the low-load condition (e.g., 25% of rated power) with the aid of pressure signals obtained at several typical recording points (i.e., spiral casing, vaneless space, draft tube cone, and draft tube elbow). Our findings reveal that at the low-load condition, the pressure fluctuation is quite significant (e.g., above 12% in terms of nondimensional values), especially in the vaneless space and spiral casing with the dominant frequency being the blade passing frequency. Furthermore, based on the characteristics of pressure fluctuation, the investigated load range is divided into three zones. For zone I (with low load), the amplitude of pressure fluctuation is highest and the dominant mechanism is the rotor–stator interaction in the vaneless space with the blade passing frequency. For zone II (with medium load), the amplitude of pressure fluctuation is less prominent (below 5%) and the dominant mechanism is the low-frequency fluctuations induced by the swirling vortex rope. For zone III (with high load), the amplitude of pressure fluctuation is quite limited (less than 3%) and the dominant mechanism is still the rotor–stator interaction but with the dominant frequency being the harmonics of blade passing frequency. Detailed examples for all three zones are given and discussed with quantitative descriptions of propagation mechanism of fluctuation.

Author(s):  
Wenjie Wang ◽  
Shouqi Yuan ◽  
Ji Pei ◽  
Giorgio Pavesi ◽  
Yandong Gu

To investigate the influence of relative positions between a radial diffuser and an annular volute on the unsteady pressure at the centrifugal pump outlet, experiment tests were carried out with five positions between the diffuser and volute in an open test rig. Statistical and frequency spectrum analyses were carried out to obtain the pressure fluctuation amplitude range and the frequency domain respectively. The results showed that the relative position has greater influence on the pressure at large flow rate than at part load condition. The dominant frequency and the Power Spectrum Density (PSD) values are affected by diffuser azimuthal position and the harmonic frequencies are determined by number of blades and vanes. The investigation can give a reference to optimize the relative angle between diffuser and volute to reduce the pressure fluctuations.


2019 ◽  
Vol 36 (4) ◽  
pp. 401-410 ◽  
Author(s):  
Xiao-Qi Jia ◽  
Bao-Ling Cui ◽  
Zu-Chao Zhu ◽  
Yu-Liang Zhang

Abstract Affected by rotor–stator interaction and unstable inner flow, asymmetric pressure distributions and pressure fluctuations cannot be avoided in centrifugal pumps. To study the pressure distributions on volute and front casing walls, dynamic pressure tests are carried out on a centrifugal pump. Frequency spectrum analysis of pressure fluctuation is presented based on Fast Fourier transform and steady pressure distribution is obtained based on time-average method. The results show that amplitudes of pressure fluctuation and blade-passing frequency are sensitive to the flow rate. At low flow rates, high-pressure region and large pressure gradients near the volute tongue are observed, and the main factors contributing to the pressure fluctuation are fluctuations in blade-passing frequency and high-frequency fluctuations. By contrast, at high flow rates, fluctuations of rotating-frequency and low frequencies are the main contributors to pressure fluctuation. Moreover, at low flow rates, pressure near volute tongue increases rapidly at first and thereafter increases slowly, whereas at high flow rates, pressure decreases sharply. Asymmetries are observed in the pressure distributions on both volute and front casing walls. With increasing of flow rate, both asymmetries in the pressure distributions and magnitude of the pressure decrease.


2014 ◽  
Vol 6 ◽  
pp. 923937 ◽  
Author(s):  
Yuekun Sun ◽  
Zhigang Zuo ◽  
Shuhong Liu ◽  
Jintao Liu ◽  
Yulin Wu

Pressure fluctuations are very important characteristics in pump turbine's operation. Many researches have focused on the characteristics (amplitude and frequencies) of pressure fluctuations at specific locations, but little researches mentioned the distribution of pressure fluctuations in a pump turbine. In this paper, 3D numerical simulations using SSTk − ω turbulence model were carried out to predict the pressure fluctuations distribution in a prototype pump turbine at pump mode. Three operating points with different mass flow rates and different guide vanes’ openings were simulated. The numerical results show how pressure fluctuations at blade passing frequency (BPF) and its harmonics vary along the whole flow path direction, as well as along the circumferential direction. BPF is the first dominant frequency in vaneless space. Pressure fluctuation component at this frequency rapidly decays towards upstream (to draft tube) and downstream (to spiral casing). In contrast, pressure fluctuations component at 3BPF spreads to upstream and downstream with almost constant amplitude. Amplitude and frequencies of pressure fluctuations also vary along different circumferential locations in vaneless space. When the mass flow and guide vanes’ opening are different, the distribution of pressure fluctuations along the two directions is different basically.


Author(s):  
Muhannad Altimemy ◽  
Justin Caspar ◽  
Alparslan Oztekin

Abstract Computational fluid dynamics simulations are conducted to characterize the spatial and temporal characteristics of the flow field inside a Francis turbine operating in the excess load regime. A high-fidelity Large Eddy Simulation (LES) turbulence model is applied to investigate the flow-induced pressure fluctuations in the draft tube of a Francis Turbine. Probes placed alongside the wall and in the center of the draft tube measure the pressure signal in the draft tube, the pressure over the turbine blades, and the power generated to compare against previous studies featuring design point and partial load operating conditions. The excess load is seen during Francis turbines in order to satisfy a spike in the electrical demand. By characterizing the flow field during these conditions, we can find potential problems with running the turbine at excess load and inspire future studies regarding mitigation methods. Our studies found a robust low-pressure region on the edges of turbine blades, which could cause cavitation in the runner region, which would extend through the draft tube, and high magnitude of pressure fluctuations were observed in the center of the draft tube.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1734
Author(s):  
Xing Zhou ◽  
Changzheng Shi ◽  
Kazuyoshi Miyagawa ◽  
Hegao Wu ◽  
Jinhong Yu ◽  
...  

Under the circumstances of rapid expansion of diverse forms of volatile and intermittent renewable energy sources, hydropower stations have become increasingly indispensable for improving the quality of energy conversion processes. As a consequence, Francis turbines, one of the most popular options, need to operate under off-design conditions, particularly for partial load operation. In this paper, a prototype Francis turbine was used to investigate the pressure fluctuations and hydraulic axial thrust pulsation under four partial load conditions. The analyses of pressure fluctuations in the vaneless space, runner, and draft tube are discussed in detail. The observed precession frequency of the vortex rope is 0.24 times that of the runner rotational frequency, which is able to travel upstream (from the draft tube to the vaneless space). Frequencies of both 24.0 and 15.0 times that of the runner rotational frequency are detected in the recording points of the runner surface, while the main dominant frequency recorded in the vaneless zone is 15.0 times that of the runner rotational frequency. Apart from unsteady pressure fluctuations, the pulsating property of hydraulic axial thrust is discussed in depth. In conclusion, the pulsation of hydraulic axial thrust is derived from the pressure fluctuations of the runner surface and is more complicated than the pressure fluctuations.


Author(s):  
Naoki Shibukawa ◽  
Yoshifumi Iwasaki ◽  
Mitsunori Watanabe

Experimental investigations with a six stage real scale low pressure steam turbine operated at a very low load conditions are presented in this paper. Although the tested 35 inch last stage blades are circumferentially coupled at both tip and mid span with an intention to reduce the vibration stress, still its increase was observed at extremely low load condition. The pressure fluctuations were measured by several silicon diaphragm sensors which were mounted on both inner and outer casings of the stator inlet, exit and blade exit position. The measurement of the vibration stress was performed by strain gauges on several blades. The power spectra of unsteady pressures were precisely investigated considering both their location and steam flow condition. And the results implied that huge reverse flow and re-circulation started in the same location as a blade-to-blade CFD predicted. In terms of the correlation between vibration stress and the flow feature, the pressure fluctuation around the blade tip produces dominant effects on the vibration stress. The unsteady pressure frequency were also investigated and compared with those of the blade resonance and rotational speed. Basic trends observed in the results are similar to what other researchers reported, and on top of that, the continuous trends of pressure fluctuation and blade vibration stress were systematically investigated. Even the wall pressure, not the pressure on blade surface, showed the effective fluctuations which excited the several nodes of natural frequencies of the last stage blade. A series of FFT of fluid force by a full annulus quasi-steady CFD simulation seems to predict dominant mode of the excitation which account for the behavior of vibration stresses. The mechanism of the rapid stress increase was examined by considering CFD results and measured unsteady pressure data together. As the test facility takes a responsibility as an independent power producer, the tests were conducted in real plant operations which include multi stage effects, inlet distortions, Reynolds Number effect and so on. The obtained data and the particular indicator of vibration stress increase can be used as a part of design tool validation with neither aerodynamic nor mechanical corrections.


2014 ◽  
Vol 6 ◽  
pp. 159380 ◽  
Author(s):  
Ji Pei ◽  
Wenjie Wang ◽  
Shouqi Yuan ◽  
Jieyun Mao

Pressure fluctuations are the main factors that can give rise to reliability problems in centrifugal pumps. The periodically unsteady pressure characteristics caused by rotor-stator interaction have been investigated by CFD calculation in a residual heat removal pump. Side chamber flow effect is also considered for the simulation to accurately predict the flow in whole flow passage. The pressure fluctuation results in time and frequency domains were considered for several typical monitoring points in impeller and diffuser channels. In addition, the pressure fluctuation intensity coefficient (PFIC) based on standard deviation was defined on each grid node for entire space and impeller revolution period. The results show that strong pressure fluctuation intensity can be found in the gap between impeller and diffuser. As a source, the fluctuation can spread to the upstream and downstream flow channels as well as the side chamber channels. Meanwhile, strong pressure fluctuation intensity can be found in the discharge tube of the circular casing. In addition, the obvious influence of operational flow rate on the PFIC distribution can be found. The analysis indicates that the pressure fluctuations in the aspects of both frequency and intensity can be used to comprehensively evaluate the unsteady pressure characteristics in centrifugal pumps.


2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Lei Cao ◽  
Zhengwei Wang ◽  
Yexiang Xiao ◽  
Yongyao Luo

Clearance flows in the sidewall gaps of centrifugal pumps are unsteady as well as main flows in the volute casing and impeller, which may cause vibration and noise, and the corresponding pressure fluctuations are related to the axial clearance size. In this paper, unsteady numerical simulations were conducted to predict the unsteady flows within the entire flow passage of a centrifugal pump operating in the design condition. Pressure fluctuation characteristics in the volute casing, impeller, and sidewall gaps were investigated with three axial clearance sizes. Results show that an axial clearance variation affects the pressure fluctuation characteristics in each flow domain by different degree. The greatest pressure fluctuation occurs at the blade pressure surface and is almost not influenced by the axial clearance variation which has a certainly effect on the pressure fluctuation characteristics around the tongue. The maximum pressure fluctuation amplitude in the sidewall gaps is larger than that in the volute casing, and different spectrum characteristics show up in the three models due to the interaction between the clearance flow and the main flow as well as the rotor-stator interaction. Therefore, clearance flow should be taken into consideration in the hydraulic design of centrifugal pumps.


2011 ◽  
Vol 133 (10) ◽  
Author(s):  
Zhifeng Yao ◽  
Fujun Wang ◽  
Lixia Qu ◽  
Ruofu Xiao ◽  
Chenglian He ◽  
...  

Pressure fluctuation is the primary reason for unstable operations of double-suction centrifugal pumps. By using flush mounted pressure transducers in the semispiral suction chamber and the volute casing of a double-suction pump, the pressure fluctuation signals were obtained and recorded at various operating conditions. Spectral analyses were performed on the pressure fluctuation signals in both frequency domain and time-frequency domain based on fast Fourier transform (FFT) and an adaptive optimal-kernel time-frequency representation (AOK TFR). The results show that pressure fluctuations at the impeller rotating frequency and some lower frequencies dominated in the semispiral suction chamber. Pressure fluctuations at the blade passing frequency, the impeller rotating frequency, and their harmonic frequencies were identified in the volute casing. The amplitude of pressure fluctuation at the blade passing frequency significantly increased when the flow rate deviated from the design flow rate. At 107% of the design flow rate, the amplitude increased more than 254% than that at the design flow rate. The time-frequency characteristics of these pressure fluctuations were affected greatly by both operating conditions and measurement locations. At partial flow rates the pulsation had a great irregularity and the amplitudes at the investigated frequencies were much larger than ones at the design flow rate. An asymmetrical pressure fluctuation structure in the volute casing was observed at all flow rates. The pulsation behavior at the blade passing frequency was the most prominent near the volute tongue zone, and the pressure waves propagated in both the radial and circumferential directions.


2015 ◽  
Vol 32 (6) ◽  
pp. 1549-1566 ◽  
Author(s):  
Lei Tan ◽  
Baoshan Zhu ◽  
Yuchuan Wang ◽  
Shuliang CAO ◽  
Shaobo Gui

Purpose – The purpose of this paper is to elucidate the detailed flow field and cavitation effect in the centrifugal pump volute at partial load condition. Design/methodology/approach – Unsteady flows in a centrifugal pump volute at non-cavitation and cavitation conditions are investigated by using a computation fluid dynamics framework combining the re-normalization group k-e turbulence model and the mass transport cavitation model. Findings – The flow field in pump volute is very complicated at part load condition with large pressure gradient and intensive vortex movement. Under cavitation conditions, the dominant frequency for most of the monitoring points in volute transit from the blade passing frequency to a lower frequency. Generally, the maximum amplitudes of pressure fluctuations in volute at serious cavitation condition is twice than that at non-cavitation condition because of the violent disturbances caused by cavitation shedding and explosion. Originality/value – The detailed flow field and cavitation effect in the centrifugal pump volute at partial load condition are revealed and analysed.