Simplified Analysis for the Association of a Constrained Receptor to an Oscillating Ligand

2016 ◽  
Vol 83 (9) ◽  
Author(s):  
Xiaofeng Chen ◽  
Bin Chen

The stability of a bond cluster upon oscillated loads under physiological conditions is strongly regulated by the kinetics of association and dissociation of a single bond, which can play critical roles in cell–matrix adhesion, cell–cell adhesion, etc. Here, we obtain a simplified analysis for the bond association process of a constrained receptor to an oscillating ligand due to its diffusion-independence, which can facilitate the potential multiscale studies in the future. Based on the analysis, our results indicate that the mean passage time for bond association intriguingly saturates at high oscillating frequencies, and there can also surprisingly exist optimal bond elasticity for bond association. This work can bring important insights into understanding of the behaviors of bond cluster under cyclic loads at the level of a single bond.

1988 ◽  
Vol 255 (2) ◽  
pp. H375-H385 ◽  
Author(s):  
M. Miniati ◽  
J. C. Parker ◽  
M. Pistolesi ◽  
J. T. Cartledge ◽  
D. J. Martin ◽  
...  

The reabsorption of albumin from the pleural space was measured in eight dogs receiving 0.5 ml intrapleural injection of 131I-labeled albumin and a simultaneous intravenous injection of 125I-labeled albumin. Plasma curves for both tracers were obtained over 24 h. The 125I-albumin curve served as input function of albumin for interstitial spaces, including pleura, whereas the 131I-albumin curve represented the output function from pleural space. The frequency function of albumin transit times from pleural space to plasma was obtained by deconvolution of input-output plasma curves. Plasma recovery of 131I-albumin was complete by 24 h, and the mean transit time from pleura to plasma averaged 7.95 +/- 1.57 (SD) h. Albumin reabsorption occurred mainly via lymphatics as indicated by experiments in 16 additional dogs in which their right lymph ducts or thoracic ducts were ligated before intrapleural injection. A pleural lymph flow of 0.020 +/- 0.003 (SD) ml.kg-1.h-1 was estimated, which is balanced by a comparable filtration of fluid into the pleural space. This suggests that, under physiological conditions, the subpleural lymphatics represent an important control mechanism of pleural liquid pressure.


2020 ◽  
Vol 49 (1) ◽  
pp. 69-85 ◽  
Author(s):  
Ron Elber

Recent advances in theory and algorithms for atomically detailed simulations open the way to the study of the kinetics of a wide range of molecular processes in biophysics. The theories propose a shift from the traditionally very long molecular dynamic trajectories, which are exact but may not be efficient in the study of kinetics, to the use of a large number of short trajectories. The short trajectories exploit a mapping to a mesh in coarse space and allow for efficient calculations of kinetics and thermodynamics. In this review, I focus on one theory: Milestoning is a theory and an algorithm that offers a hierarchical calculation of properties of interest, such as the free energy profile and the mean first passage time. Approximations to the true long-time dynamics can be computed efficiently and assessed at different steps of the investigation. The theory is discussed and illustrated using two biophysical examples: ion permeation through a phospholipid membrane and protein translocation through a channel.


2016 ◽  
Vol 08 (03) ◽  
pp. 1650040 ◽  
Author(s):  
Ji Lin ◽  
Jin Qian ◽  
Jun Yin ◽  
Yuan Lin

We investigate the cohesive response of biointerfaces mediated by noncovalent receptor–ligand bonding under monotonic, cyclic or other types of loading. By examining the spatiotemporal evolution of the state probability distribution that describes the collective association and dissociation kinetics of interfacial bonds, we show that such interfaces resist the imposed surface separation in a strongly rate-dependent manner. Remarkable hysteresis is exhibited when the interfaces are exposed to single stretching and relaxation cycles at high loading rates, and this hysteretic response shifts in consecutive multiple cycles. There generally exists an optimal ramping velocity that gives rise to the maximum energy dissipation at the interfaces. These results should be useful in understanding the cell-matrix adhesion and de-adhesion phenomena under dynamic and repetitive forces, as well as the adhesion-mediated cellular behaviors such as migration and reorientation.


Author(s):  
Valentin Rausch ◽  
Sina Neugebauer ◽  
Tim Leschinger ◽  
Lars Müller ◽  
Kilian Wegmann ◽  
...  

Abstract Introduction This study aimed to describe the involvement of the lesser sigmoid notch in fractures to the coronoid process. We hypothesized that injuries to the lateral aspect of the coronoid process regularly involve the annular ligament insertion at the anterior lesser sigmoid notch. Material and Methods Patients treated for a coronoid process fracture at our institution between 06/2011 and 07/2018 were included. We excluded patients < 18 years, patients with arthritic changes or previous operative treatment to the elbow, and patients with concomitant injuries to the proximal ulna. In patients with involvement of the lesser sigmoid notch, the coronoid height and fragment size (anteroposterior, mediolateral, and craniocaudal) were measured. Results Seventy-two patients (mean age: 47 years ± 17.6) could be included in the study. Twenty-one patients (29.2%) had a fracture involving the lateral sigmoid notch. The mean anteroposterior fragment length was 7 ± 1.6 mm. The fragment affected a mean of 43 ± 10.8% of the coronoid height. The mean mediolateral size of the fragment was 10 ± 5.0 mm, and the mean cranio-caudal size was 7 ± 2.7 mm. Conclusion Coronoid fractures regularly include the lesser sigmoid notch. These injuries possibly affect the anterior annular ligament insertion which is important for the stability of the proximal radioulnar joint and varus stability of the elbow.


1977 ◽  
Vol 16 (04) ◽  
pp. 157-162 ◽  
Author(s):  
C. Schümichen ◽  
B. Mackenbrock ◽  
G. Hoffmann

SummaryThe bone-seeking 99mTc-Sn-pyrophosphate compound (compound A) was diluted both in vitro and in vivo and proved to be unstable both in vitro and in vivo. However, stability was much better in vivo than in vitro and thus the in vitro stability of compound A after dilution in various mediums could be followed up by a consecutive evaluation of the in vivo distribution in the rat. After dilution in neutral normal saline compound A is metastable and after a short half-life it is transformed into the other 99mTc-Sn-pyrophosphate compound A is metastable and after a short half-life in bone but in the kidneys. After dilution in normal saline of low pH and in buffering solutions the stability of compound A is increased. In human plasma compound A is relatively stable but not in plasma water. When compound B is formed in a buffering solution, uptake in the kidneys and excretion in urine is lowered and blood concentration increased.It is assumed that the association of protons to compound A will increase its stability at low concentrations while that to compound B will lead to a strong protein bond in plasma. It is concluded that compound A will not be stable in vivo because of a lack of stability in the extravascular space, and that the protein bond in plasma will be a measure of its in vivo stability.


1983 ◽  
Vol 22 (05) ◽  
pp. 246-250 ◽  
Author(s):  
M. Al-Hilli ◽  
H. M. A. Karim ◽  
M. H. S. Al-Hissoni ◽  
M. N. Jassim ◽  
N. H. Agha

Gelchromatography column scanning has been used to study the fractions of reduced hydrolyzed 99mTc, 99mTc-pertechnetate and 99mTc-chelate in a 99mTc-glucoheptonate (GH) preparation. A stable high labelling yield of 99mTc-GH complex in the radiopharmaceutical has been obtained with a concentration of 40-50 mg of glucoheptonic acid-calcium salt and not less than 0.45 mg of SnCl2 2 H2O at an optimal pH between 6.5 and 7.0. The stability of the complex has been found significantly affected when sodium hydroxide solution was used for the pH adjustment. However, an alternative procedure for final pH adjustment of the preparation has been investigated providing a stable complex for the usual period of time prior to the injection. The organ distribution and the blood clearance data of 99mTc-GH in rabbits were relatively similar to those reported earlier. The mean concentration of the radiopharmaceutical in both kidneys has been studied in normal subjects for one hour with a scintillation camera and the results were satisfactory.


1980 ◽  
Vol 45 (3) ◽  
pp. 777-782 ◽  
Author(s):  
Milan Šolc

The establishment of chemical equilibrium in a system with a reversible first order reaction is characterized in terms of the distribution of first passage times for the state of exact chemical equilibrium. The mean first passage time of this state is a linear function of the logarithm of the total number of particles in the system. The equilibrium fluctuations of composition in the system are characterized by the distribution of the recurrence times for the state of exact chemical equilibrium. The mean recurrence time is inversely proportional to the square root of the total number of particles in the system.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Biao Xiang ◽  
Xingxing Wang ◽  
Gang Wu ◽  
Yichen Xu ◽  
Menghan Wang ◽  
...  

AbstractNumerous factors can influence the force exerted by clear aligners on teeth. This study aimed to investigate the stability of the force delivered by two different material appliances. 90 clear aligners with 2 materials and three different activations were designed and fabricated. Then, a device was employed to measure the force generated by the two types of PET-G material appliances immersed in artificial saliva for 0, 3, 7, 10, 14 days. Scanning electron microscopy was applied to observe the morphologic alterations on the aligner surfaces, respectively. The forces generated by different activation appliance exhibited differently, 0.0 mm < 0.1 mm < 0.2 mm. In addition, increasing the immersion times and the orthodontic force also decreased, but the forces decreased differently. Compared with the forces of conventional PETG appliances with 0.20 mm activation, the modified PETG appliances with the same activation exhibited significantly higher mean force. When comparing the mean force for modified PETG appliances after 10 and 14 days with conventional PETG appliances, the delivery forces exhibited significant differences (P < 0.05). The force delivered by both materials decreased obviously following artificial saliva immersion, and the force generated by modified aligners exhibited better stability than conventional aligners.


Sign in / Sign up

Export Citation Format

Share Document