Right–Left Differences in Knee Extension Stiffness for the Normal Rat Knee: In Vitro Measurements Using a New Testing Apparatus

2016 ◽  
Vol 138 (4) ◽  
Author(s):  
Keith L. Markolf ◽  
Denis Evseenko ◽  
Frank Petrigliano

Knee stiffness following joint injury or immobilization is a common clinical problem, and the rat has been used as a model for studies related to joint stiffness and limitation of motion. Knee stiffness measurements have been reported for the anesthetized rat, but it is difficult to separate the contributions of muscular and ligamentous restraints to the recorded values. in vitro testing of isolated rat knees devoid of musculature allows measurement of joint structural properties alone. In order to measure the effects of therapeutic or surgical interventions designed to alter joint stiffness, the opposite extremity is often used as a control. However, right–left stiffness differences for the normal rat knee have not been reported in the literature. If stiffness changes observed for a treatment group are within the normal right–left variation, validity of the results could be questioned. The objectives of this study were to utilize a new testing apparatus to measure right–left stiffness differences during knee extension in a population of normal rat knees and to document repeatability of the stiffness measurements on successive testing days. Moment versus rotation curves were recorded for 15 right–left pairs of normal rat knees on three consecutive days, with overnight specimen storage in a refrigerator. Each knee was subjected to ten loading–unloading cycles, with the last loading curve used for analysis. Angular rotation (AR), defined here as the change in flexion–extension angle from a specified applied joint moment, is commonly used as a measure of overall joint stiffness. For these tests, ARs were measured from the recorded test curves with a maximum applied extension moment of 100 g cm. Mean rotations for testing days 2 and 3 were 0.81–1.25 deg lower (p < 0.001) than for day 1, but were not significantly different from each other. For each testing day, mean rotations for right knees were 1.12–1.30 deg greater (p < 0.001) than left knees. These right–left stiffness differences should be considered when interpreting the results of knee treatment studies designed to alter knee stiffness when using the opposite extremity as a control.

1999 ◽  
Vol 121 (2) ◽  
pp. 222-228 ◽  
Author(s):  
A. M. Ahmed ◽  
N. A. Duncan ◽  
M. Tanzer

This study sought to determine whether a general pattern describing the three-dimensional tracking characteristics of the human patella could be established, and if not, then to determine the extent and nature of interspecimen variations in the characteristics in a normal population. Using 32 fresh-frozen knees subjected to extensor moment magnitudes similar to those in “static-lifting” and “leg-raising against resistance” maneuvers, patellar displacements were measured in the knee extension range 120 to 0 deg. For static-lifting, a constant foot-floor reaction of 334 N was applied. For leg-raising, a constant net quadriceps tension of 668 N was used throughout the extension range. Measurements were taken with a calibrated six-degree-of-freedom electromechanical goniometer and a displacement coordinate system referenced to the geometry of individual specinens. The three patellar displacements in the plane of knee extension/flexion (extension rotation, and anterior and proximal translations) consistently demonstrated the same pattern in the entire knee extension range with an average coefficient of variation of 13 percent. For knee angles greater than 45 deg, the three other displacements (medial lateral translation, and rotations about the anterior–posterior and proximal–distal axes) followed a general pattern. However, for knee angles less than 45 deg, these displacements differed considerably between specimens for each loading condition, both in terms of magnitude (average coefficient of variation: 70 percent), and direction.


2002 ◽  
Vol 22 (12) ◽  
pp. 1476-1489 ◽  
Author(s):  
Nancy F. Cruz ◽  
Gerald A. Dienel

The concentration of glycogen, the major brain energy reserve localized mainly in astrocytes, is generally reported as about 2 or 3 μmol/g, but sometimes as high as 3.9 to 8 μmol/g, in normal rat brain. The authors found high but very different glycogen levels in two recent studies in which glycogen was determined by the routine amyloglucosidase procedure in 0.03N HCl digests either of frozen powders (4.8 to 6 μmol/g) or of ethanol-insoluble fractions (8 to 12 μmol/g). To evaluate the basis for these discrepant results, glycogen was assayed in parallel extracts of the same samples. Glycogen levels in ethanol extracts were twice those in 0.03N HCl digests, suggesting incomplete enzyme inactivation even with very careful thawing. The very high glycogen levels were biologically active and responsive to physiologic and pharmacological challenge. Glycogen levels fell after brief sensory stimulation, and metabolic labeling indicated its turnover under resting conditions. About 95% of the glycogen was degraded under in vitro ischemic conditions, and its “carbon equivalents” recovered mainly as glc, glc-P, and lactate. Resting glycogen stores were reduced by about 50% by chronic inhibition of nitric oxide synthase. Because neurotransmitters are known to stimulate glycogenolysis, stress or sensory activation due to animal handling and tissue-sampling procedures may stimulate glycogenolysis during an experiment, and glycogen lability during tissue sampling and extraction can further reduce glycogen levels. The very high glycogen levels in normal rat brain suggest an unrecognized role for astrocytic energy metabolism during brain activation.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ryosuke Nakamura ◽  
Nao Hiwatashi ◽  
Renjie Bing ◽  
Carina P. Doyle ◽  
Ryan C. Branski

AbstractVocal fold (VF) fibrosis is a major cause of intractable voice-related disability and reduced quality of life. Excision of fibrotic regions is suboptimal and associated with scar recurrence and/or further iatrogenic damage. Non-surgical interventions are limited, putatively related to limited insight regarding biochemical events underlying fibrosis, and downstream, the lack of therapeutic targets. YAP/TAZ integrates diverse cell signaling events and interacts with signaling pathways related to fibrosis, including the TGF-β/SMAD pathway. We investigated the expression of YAP/TAZ following vocal fold injury in vivo as well as the effects of TGF-β1 on YAP/TAZ activity in human vocal fold fibroblasts, fibroblast-myofibroblast transition, and TGF-β/SMAD signaling. Iatrogenic injury increased nuclear localization of YAP and TAZ in fibrotic rat vocal folds. In vitro, TGF-β1 activated YAP and TAZ in human VF fibroblasts, and inhibition of YAP/TAZ reversed TGF-β1-stimulated fibroplastic gene upregulation. Additionally, TGF-β1 induced localization of YAP and TAZ in close proximity to SMAD2/3, and nuclear accumulation of SMAD2/3 was inhibited by a YAP/TAZ inhibitor. Collectively, YAP and TAZ were synergistically activated with the TGF-β/SMAD pathway, and likely essential for the fibroplastic phenotypic shift in VF fibroblasts. Based on these data, YAP/TAZ may evolve as an attractive therapeutic target for VF fibrosis.


2021 ◽  
Vol 11 (8) ◽  
pp. 3391
Author(s):  
Jan Marušič ◽  
Goran Marković ◽  
Nejc Šarabon

The purpose of this study was to evaluate intra- and inter-session reliability of the new, portable, and externally fixated dynamometer called MuscleBoard® for assessing the strength of hip and lower limb muscles. Hip abduction, adduction, flexion, extension, internal and external rotation, knee extension, ankle plantarflexion, and Nordic hamstring exercise strength were measured in three sessions (three sets of three repetitions for each test) on 24 healthy and recreationally active participants. Average and maximal value of normalized peak torque (Nm/kg) from three repetitions in each set and agonist:antagonist ratios (%) were statistically analyzed; the coefficient of variation and intra-class correlation coefficient (ICC2,k) were calculated to assess absolute and relative reliability, respectively. Overall, the results display high to excellent intra- and inter-session reliability with low to acceptable within-individual variation for average and maximal peak torques in all bilateral strength tests, while the reliability of unilateral strength tests was moderate to good. Our findings indicate that using the MuscleBoard® dynamometer can be a reliable device for assessing and monitoring bilateral and certain unilateral hip and lower limb muscle strength, while some unilateral strength tests require some refinement and more extensive familiarization.


2021 ◽  
Vol 49 (4) ◽  
pp. 994-1004
Author(s):  
Andreas Martin Seitz ◽  
Florian Schall ◽  
Steffen Paul Hacker ◽  
Stefan van Drongelen ◽  
Sebastian Wolf ◽  
...  

Background: The anatomic appearance and biomechanical and clinical importance of the anterior meniscus roots are well described. However, little is known about the loads that act on these attachment structures under physiological joint loads and movements. Hypotheses: As compared with uniaxial loading conditions under static knee flexion angles or at very low flexion-extension speeds, more realistic continuous movement simulations in combination with physiological muscle force simulations lead to significantly higher anterior meniscus attachment forces. This increase is even more pronounced in combination with a longitudinal meniscal tear or after total medial meniscectomy. Study Design: Controlled laboratory study. Methods: A validated Oxford Rig–like knee simulator was used to perform a slow squat, a fast squat, and jump landing maneuvers on 9 cadaveric human knee joints, with and without muscle force simulation. The strains in the anterior medial and lateral meniscal periphery and the respective attachments were determined in 3 states: intact meniscus, medial longitudinal tear, and total medial meniscectomy. To determine the attachment forces, a subsequent in situ tensile test was performed. Results: Muscle force simulation resulted in a significant strain increase at the anterior meniscus attachments of up to 308% ( P < .038) and the anterior meniscal periphery of up to 276%. This corresponded to significantly increased forces ( P < .038) acting in the anteromedial attachment with a maximum force of 140 N, as determined during the jump landing simulation. Meniscus attachment strains and forces were significantly influenced ( P = .008) by the longitudinal tear and meniscectomy during the drop jump simulation. Conclusion: Medial and lateral anterior meniscus attachment strains and forces were significantly increased with physiological muscle force simulation, corroborating our hypothesis. Therefore, in vitro tests applying uniaxial loads combined with static knee flexion angles or very low flexion-extension speeds appear to underestimate meniscus attachment forces. Clinical Relevance: The data of the present study might help to optimize the anchoring of meniscal allografts and artificial meniscal substitutes to the tibial plateau. Furthermore, this is the first in vitro study to indicate reasonable minimum stability requirements regarding the reattachment of torn anterior meniscus roots.


2011 ◽  
Vol 36 (4) ◽  
pp. 297-302 ◽  
Author(s):  
J. Henderson ◽  
M. Sutcliffe ◽  
P. Gillespie

Extensor tendons in the finger are flat and not amenable to repair by core and epitendinous sutures. Mattress sutures and Kessler repairs without epitendinous stitching are often used for extensor tendon divisions in the fingers. Except when in full extension, the finger presents a series of curved surfaces (at each joint) to the tendon. It was hypothesized that extensor tendons are subject to the ‘tension band’ principle and that they might be amenable to repair by dorsal-only epitendinous sutures. A Silfverskiöld dorsal-only repair was compared with mattress and Kessler repairs in vitro on a curvilinear testing apparatus. The epitendinous technique was found to be significantly more resistant to gapping and rupture, as well as more resistant to deformation (i.e. stiffer) than the conventional techniques.


2017 ◽  
Vol 59 (3) ◽  
pp. 327-335 ◽  
Author(s):  
David Volkheimer ◽  
Fabio Galbusera ◽  
Christian Liebsch ◽  
Sabine Schlegel ◽  
Friederike Rohlmann ◽  
...  

Background Several in vitro studies investigated how degeneration affects spinal motion. However, no consensus has emerged from these studies. Purpose To investigate how degeneration grading systems influence the kinematic output of spinal specimens. Material and Methods Flexibility testing was performed with ten human T12-S1 specimens. Degeneration was graded using two different classifications, one based on X-ray and the other one on magnetic resonance imaging (MRI). Intersegmental rotation (expressed by range of motion [ROM] and neutral zone [NZ]) was determined in all principal motion directions. Further, shear translation was measured during flexion/extension motion. Results The X-ray grading system yielded systematically lesser degeneration. In flexion/extension, only small differences in ROM and NZ were found between moderately degenerated motion segments, with only NZ for the MRI grading reaching statistical significance. In axial rotation, a significant increase in NZ for moderately degenerated segments was found for both grading systems, whereas the difference in ROM was significant only for the MRI scheme. Generally, the relative increases were more pronounced for the MRI classification compared to the X-ray grading scheme. In lateral bending, only relatively small differences between the degeneration groups were found. When evaluating shear translations, a non-significant increase was found for moderately degenerated segments. Motion segment segments tended to regain stability as degeneration progressed without reaching the level of statistical significance. Conclusion We found a fair agreement between the grading schemes which, nonetheless, yielded similar degeneration-related effects on intersegmental kinematics. However, as the trends were more pronounced using the Pfirrmann classification, this grading scheme appears superior for degeneration assessment.


2007 ◽  
Vol 40 (12) ◽  
pp. 2767-2773 ◽  
Author(s):  
Joseph J. Crisco ◽  
Lindsey Fujita ◽  
David B. Spenciner

2022 ◽  
pp. 1-9

OBJECTIVE The traditional anterior approach for multilevel severe cervical ossification of the posterior longitudinal ligament (OPLL) is demanding and risky. Recently, a novel surgical procedure—anterior controllable antedisplacement and fusion (ACAF)—was introduced by the authors to deal with these problems and achieve better clinical outcomes. However, to the authors’ knowledge, the immediate and long-term biomechanical stability obtained after this procedure has never been evaluated. Therefore, the authors compared the postoperative biomechanical stability of ACAF with those of more traditional approaches: anterior cervical discectomy and fusion (ACDF) and anterior cervical corpectomy and fusion (ACCF). METHODS To determine and assess pre- and postsurgical range of motion (ROM) (2 Nm torque) in flexion-extension, lateral bending, and axial rotation in the cervical spine, the authors collected cervical areas (C1–T1) from 18 cadaveric spines. The cyclic fatigue loading test was set up with a 3-Nm cycled load (2 Hz, 3000 cycles). All samples used in this study were randomly divided into three groups according to surgical procedures: ACDF, ACAF, and ACCF. The spines were tested under the following conditions: 1) intact state flexibility test; 2) postoperative model (ACDF, ACAF, ACCF) flexibility test; 3) cyclic loading (n = 3000); and 4) fatigue model flexibility test. RESULTS After operations were performed on the cadaveric spines, the segmental and total postoperative ROM values in all directions showed significant reductions for all groups. Then, the ROMs tended to increase during the fatigue test. No significant crossover effect was detected between evaluation time and operation method. Therefore, segmental and total ROM change trends were parallel among the three groups. However, the postoperative and fatigue ROMs in the ACCF group tended to be larger in all directions. No significant differences between these ROMs were detected in the ACDF and ACAF groups. CONCLUSIONS This in vitro biomechanical study demonstrated that the biomechanical stability levels for ACAF and ACDF were similar and were both significantly greater than that of ACCF. The clinical superiority of ACAF combined with our current results showed that this procedure is likely to be an acceptable alternative method for multilevel cervical OPLL treatment.


Sign in / Sign up

Export Citation Format

Share Document