Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter

2016 ◽  
Vol 138 (3) ◽  
Author(s):  
L. (Bert) van de Ridder ◽  
Wouter B. J. Hakvoort ◽  
Johannes van Dijk ◽  
Joost C. Lötters ◽  
André de Boer

In this paper, a vibration isolated design of a Coriolis mass-flow meter (CMFM) is proposed by introducing a compliant connection between the casing and the tube displacement sensors, with the objective to obtain a relative displacement measurement of the fluid conveying tube, dependent on the tube actuation and mass-flow, but independent of external vibrations. The transfer from external vibrations to the relative displacement measurement is analyzed and the design is optimized to minimize this transfer. The influence of external vibrations on a compliant sensor element and the tube are made equal by tuning the resonance frequency and damping of the compliant sensor element and therefore the influence on the relative displacement measurement is minimized. The optimal tuning of the parameters is done actively by acceleration feedback. Based on simulation results, a prototype is built and validated. The validated design shows more than 24 dB reduction of the influence of external vibrations on the mass-flow measurement value of a CMFM, without affecting the sensitivity for mass-flow.

Author(s):  
L. (Bert) van de Ridder ◽  
Wouter B. J. Hakvoort ◽  
Johannes van Dijk

In this paper a vibration isolated design of the Coriolis Mass-Flow Meter (CMFM) is proposed, by introducing a compliant connection between the casing and the tube displacement sensors with the intention to obtain a relative displacement measurement of the fluid conveying tube, dependent on the tube actuation and mass-flow, but independent of casing excitations. Analyses are focussed on changing the transfer function of support excitations to the relative displacement measurement. The influence of external vibrations on a compliant sensor element and the tube are made equal by tuning the resonance frequency and damping of the compliant sensor element and therefore the influence on the relative displacement measurement is minimised. Based on simulation results, a prototype is built and validated. The validated design show a 20dB reduction of the influence of external vibrations on the mass-flow measurement value of a CMFM, without affecting the sensitivity for mass-flow.


Mechatronics ◽  
2016 ◽  
Vol 36 ◽  
pp. 167-179 ◽  
Author(s):  
L. van de Ridder ◽  
W.B.J. Hakvoort ◽  
D.M. Brouwer ◽  
J. van Dijk ◽  
J.C. Lötters ◽  
...  

2019 ◽  
Vol 90 ◽  
pp. 311-318 ◽  
Author(s):  
A. García-Berrocal ◽  
C. Montalvo ◽  
P. Carmona ◽  
J. Blázquez

2016 ◽  
Vol 165 ◽  
pp. 759-764 ◽  
Author(s):  
Chih-Wei Lin ◽  
Mahmoud Nazeri ◽  
Ayan Bhattacharji ◽  
George Spicer ◽  
M. Mercedes Maroto-Valer

Sign in / Sign up

Export Citation Format

Share Document