A Needlelike Probe for Temperature Monitoring During Laser Ablation Based on Fiber Bragg Grating: Manufacturing and Characterization

2015 ◽  
Vol 9 (4) ◽  
Author(s):  
Davide Polito ◽  
Michele Arturo Caponero ◽  
Andrea Polimadei ◽  
Paola Saccomandi ◽  
Carlo Massaroni ◽  
...  

Temperature distribution monitoring in tissue undergoing laser ablation (LA) could be beneficial for improving treatment outcomes. Among several thermometric techniques employed in LA, fiber Bragg grating (FBG) sensors show valuable characteristics, although their sensitivity to strain entails measurement error for patient respiratory movements. Our work describes a solution to overcome this issue by housing an FBG in a surgical needle. The metrological properties of the probes were assessed in terms of thermal sensitivity (0.027 nm °C−1 versus 0.010 nm °C−1 for epoxy liquid encapsulated probe and thermal paste one, respectively) and response time (about 100 ms) and compared with properties of nonencapsulated FBG (sensitivity of 0.010 nm °C−1, response time of 43 ms). The error due to the strain caused by liver movements, simulating a typical respiratory pattern, was assessed: the strain induces a probes output error less than 0.5 °C, which is negligible when compared to the response of nonencapsulated FBG (2.5 °C). The metallic needle entails a measurement error, called artifact, due to direct absorption of the laser radiation. The analysis of the artifact was performed by employing the probes for temperature monitoring on liver undergoing LA. Experiments were performed at two laser powers (i.e., 2 W and 4 W) and at nine distances between the probes and the laser applicator. The artifact decreases with the distance and increases with the power: it exceeds 10 °C at 4 W, when the encapsulated probes are placed at 3.6 mm and 0 deg from the applicator, and it is lower than 1 °C for distance higher than 5 mm and angle higher than 30 deg.

2019 ◽  
Vol 9 (15) ◽  
pp. 3107 ◽  
Author(s):  
Carlo Molardi ◽  
Tiago Paixão ◽  
Aidana Beisenova ◽  
Rui Min ◽  
Paulo Antunes ◽  
...  

The characterization of Fiber Bragg Grating (FBG) sensors on a high-scattering fiber, having the core doped with MgO nanoparticles for polarization-dependent temperature sensing is reported. The fiber has a scattering level 37.2 dB higher than a single-mode fiber. FBGs have been inscribed by mean of a near-infrared femtosecond laser and a phase mask, with Bragg wavelength around 1552 nm. The characterization shows a thermal sensitivity of 11.45 pm/°C. A polarization-selective thermal behavior has been obtained, with sensitivity of 11.53 pm/°C for the perpendicular polarization (S) and 11.08 pm/°C for the parallel polarization (P), thus having 4.0% different sensitivity between the two polarizations. The results show the inscription of high-reflectivity FBGs onto a fiber core doped with nanoparticles, with the possibility of having reflectors into a fiber with tailored Rayleigh scattering properties.


Author(s):  
Ruiqi Ma ◽  
Guoqing Feng ◽  
Huilong Ren ◽  
Peng Fu ◽  
Shuang Wu ◽  
...  

Hull monitoring system with Fiber Bragg Grating (FBG) sensors increasingly receives people’s attentions. However, for the ship hull monitoring, the deformation of hull girder changes a lot as is subjected to a huge temperature variation. Therefore, the compensation method with only FBG temperature self-correction is not suitable for the hull monitoring sensors because no material thermal expansion effects are reasonably included. In this paper, the new compensation method of hull monitoring FBG sensor based on the sensor theory with both FBG temperature self-correction and steel thermal expansion effects correction is studied. The coupled compensation method suitable for hull monitoring sensor is obtained by theoretical derivation. As the comparison, the coupled compensation experiment was carried out. The results show that the relative error under the temperature compensation method is large in the case of drastic strain and temperature changes, and the correction results of the tested method will be closer to the true level.


2013 ◽  
Vol 328 ◽  
pp. 193-197
Author(s):  
Si Jin Xin ◽  
Zhen Tong

The metal fatigue is an important factor to cause an accident in machine operation, so metal fatigue test is a significant procedure in manufacturing. Fiber Bragg Grating (FBG), as an innovative sensor, has been applied to the measurement of various rotating machines. In this paper, the time-frequency analysis is used to detect the fatigue feature of a titanium alloy measured by FBG sensors. Furthermore, the Hilbert-Huang transform (HHT) is more effective to observe the fatigue limit of the titanium alloy sheet, compared to the Wavelet transform (WT).


Author(s):  
Hong-Il Kim ◽  
Lae-Hyong Kang ◽  
Jae-Hung Han

Dimensional stability of the space structures, such as large telescope mirrors or metering substructures, is very important because even extremely small deformations of these structures might degrade the optical performances. Therefore, precise deformation data of the space structures according to environment change are required to design these structures correctly. Also, real-time deformation monitoring of these structures in space environment is demanded to verify whether these structures are properly designed or manufactured. FBG (fiber Bragg grating) sensors are applicable to real time monitoring of the space structure because they can be embedded onto the structures with minimal weight penalty. In this research, therefore, thermal deformation measurement system for the space structures, composed of FBG sensors for real time strain measurement and DMI (displacement measuring interferometers) for accurate specimen expansion data acquisition, is developed. Thermal strains measured by distributed FBG sensors are evaluated by the comparison with the strains obtained by highly accurate DMI.


2022 ◽  
Vol 12 (2) ◽  
pp. 886
Author(s):  
Hun-Kook Choi ◽  
Young-Jun Jung ◽  
Bong-Ahn Yu ◽  
Jae-Hee Sung ◽  
Ik-Bu Sohn ◽  
...  

This paper demonstrates the fabrication of radiation-resistant fiber Bragg grating (FBG) sensors using infrared femtosecond laser irradiation. FBG sensors were written inside acrylate-coated fluorine-doped single-mode specialty optical fibers. We detected the Bragg resonance at 1542 nm. By controlling the irradiation conditions, we improved the signal strength coming out from the FBG sensors. A significant reduction in the Bragg wavelength shift was detected in the fabricated FBG sensors for a radiation dose up to 105 gray, indicating excellent radiation resistance capabilities. We also characterized the temperature sensitivity of the radiation-resistant FBG sensors and detected outstanding performance.


Sensors ◽  
2018 ◽  
Vol 18 (6) ◽  
pp. 1799 ◽  
Author(s):  
Yiming Zhao ◽  
Nong Zhang ◽  
Guangyao Si ◽  
Xuehua Li

Fiber Bragg grating (FBG) measuring bolts, as a useful tool to evaluate the behaviors of steel bolts in underground engineering, can be manufactured by gluing the FBG sensors inside the grooves, which are usually symmetrical cuts along the steel bolt rod. The selection of the cut shape and the glue types could perceivably affect the final supporting strength of the bolts. Unfortunately, the impact of cut shape and glue type on bolting strength is not yet clear. In this study, based on direct tension tests, full tensile load–displacement curves of rock bolts with different groove shapes were obtained and analyzed. The effects of groove shape on the bolt strength were discussed, and the stress redistribution in the cross-section of a rock bolt with different grooves was simulated using ANSYS. The results indicated that the trapezoidal groove is best for manufacturing the FBG bolt due to its low reduction of supporting strength. Four types of glues commonly used for the FBG sensors were assessed by conducting tensile tests on the mechanical testing and simulation system and the static and dynamic optical interrogators system. Using linear regression analysis, the relationship between the reflected wavelength of FBG sensors and tensile load was obtained. Practical recommendations for glue selection in engineering practice are also provided.


2018 ◽  
Vol 16 (7) ◽  
pp. 070604 ◽  
Author(s):  
Xiaofeng Wang Xiaofeng Wang ◽  
Yongxing Guo Yongxing Guo ◽  
Li Xiong Li Xiong

2020 ◽  
Author(s):  
N. A. Rosman ◽  
C. B. M. Rashidi ◽  
S. A. Aljunid ◽  
R. Endut

Sign in / Sign up

Export Citation Format

Share Document