Development of a Solar Receiver Based on Compact Heat Exchanger Technology for Supercritical Carbon Dioxide Power Cycles

2015 ◽  
Vol 137 (3) ◽  
Author(s):  
Saeb M. Besarati ◽  
D. Yogi Goswami ◽  
Elias K. Stefanakos

Supercritical carbon dioxide (s-CO2) can be used both as a heat transfer and working fluid in solar power tower plants. The main concern in the design of a direct s-CO2 receiver is the high operating pressures, i.e., close to 20 MPa. At such high pressures, conventional receivers do not exhibit the necessary mechanical strength or thermal performance. In this paper, a receiver based on compact heat exchanger technology is developed. The receiver consists of a group of plates with square-shaped channels which are diffusion bonded together to tolerate the high operating pressure. A computational model is developed and validated against data in the literature. Inconel 625 is used as the base material because of its superior resistance against corrosion in the presence of s-CO2. The receiver heats s-CO2 with mass flow rate of 1 kg/s from 530 °C to 700 °C under a solar flux density of 500 kW/m2. The influence of different parameters on the performance of the receiver is evaluated by a parametric analysis. Subsequently, a multi-objective optimization is performed to determine the optimal geometry of the heat exchanger considering the tradeoff between objective functions, such as unit thermal resistance and pressure drop. The design variables are hydraulic diameter, number of layers, and distance between the channels. The mechanical strength of the system is the constraint to the problem, which is evaluated using an ASME code for the pressure vessels. Finally, the temperature profiles inside the channels and the surface of the receiver are presented. It is shown that the fluid reaches the desired temperature while the maximum temperature of the surface remains well below the material limit.

2020 ◽  
pp. 1-34
Author(s):  
Matthew Carlson ◽  
Francisco Alvarez

Abstract A new generation of Concentrating Solar Power (CSP) technologies is under development to provide dispatchable renewable power generation and reduce the levelized cost of electricity (LCOE) to 6 cents/kWh by leveraging heat transfer fluids (HTF) capable of operation at higher temperatures and coupling with higher efficiency power conversion cycles. The U.S. Department of Energy (DOE) has funded three pathways for Generation 3 CSP (Gen3CSP) technology development to leverage solid, liquid, and gaseous HTFs to transfer heat to a supercritical carbon dioxide (sCO2) Brayton cycle. This paper presents the design and off-design capabilities of a 1 MWth sCO2 test system that can provide sCO2 coolant to the primary heat exchangers (PHX) coupling the high-temperature HTFs to the sCO2 working fluid of the power cycle. This system will demonstrate design, performance, lifetime, and operability at a scale relevant to commercial CSP. A dense-phase high pressure canned motor pump is used to supply up to 5.3 kg/s of sCO2 flow to the primary heat exchanger at pressures up to 250 bar and temperatures up to 715 °C with ambient air as the ultimate heat sink. Key component requirements for this system are presented in this paper.


Author(s):  
Joshua Schmitt ◽  
David Amos ◽  
Jayanta Kapat

The goal of this study is to design and assess the effectiveness of a micro-channel recuperator using supercritical carbon dioxide as a working fluid. A one-dimensional thermal analysis is performed for a micro-channel recuperator suitable for a Brayton cycle with a nominal 100 MW class turbomachine. The impact of supercritical carbon dioxide properties near the critical point on the thermal performance of the recuperator is studied in detail. The cycle parameters are first obtained from an overall cycle analysis. Two adjacent flow passages with square cross-section in counter-flow configuration are considered for this analysis along with appropriate symmetry. The high pressure of SCO2 is also addressed and the structural stresses on the micro-channel walls are analyzed. Only the axial temperature variations in the hot stream and the cold stream are considered in the one-dimensional analysis. Each channel is discretized in the axial direction. Axial conduction through the wall is included in the energy balance. Of particular interest in this analysis is the variation of transport properties of the CO2 working fluid as thermodynamic conditions approach the critical point. These property variations are provided to the computer code through the REFPROP database. Over the length of the heat exchanger local changes in Reynolds number, Nusselt number, and heat transfer coefficient are charted. From the results of the heat transfer calculations, the log mean temperature difference and heat exchange effectiveness of the heat exchanger is calculated. Using the code to produce multiple results, the optimum heat exchanger design is found. Recommendations on the manufacturing method of a micro-channel recuperator are made.


Author(s):  
Alan Kruizenga ◽  
Mark Anderson ◽  
Roma Fatima ◽  
Michael Corradini ◽  
Aaron Towne ◽  
...  

The increasing importance of improving efficiency and reducing capital costs has led to significant work studying advanced Brayton cycles for high temperature energy conversion. Using compact, highly efficient, diffusion-bonded heat exchangers for the recuperators has been a noteworthy improvement in the design of advanced carbon dioxide Brayton cycles. These heat exchangers will operate near the pseudocritical point of carbon dioxide, making use of the drastic variation of the thermophysical properties. This paper focuses on the experimental measurements of heat transfer under cooling conditions, as well as pressure drop characteristics within a prototypic printed circuit heat exchanger. Studies utilize type-316 stainless steel, nine channel, semi-circular test section, and supercritical carbon dioxide serves as the working fluid throughout all experiments. The test section channels have a hydraulic diameter of 1.16 mm and a length of 0.5 m. The mini-channels are fabricated using current chemical etching technology, emulating techniques used in current diffusion-bonded printed circuit heat exchanger manufacturing. Local heat transfer values were determined using measured wall temperatures and heat fluxes over a large set of experimental parameters that varied system pressure, inlet temperature, and mass flux. Experimentally determined heat transfer coefficients and pressure drop data are compared to correlations and earlier data available in literature. Modeling predictions using the computational fluid dynamics (CFD) package FLUENT are included to supplement experimental data. All nine channels were modeled using known inlet conditions and measured wall temperatures as boundary conditions. The CFD results show excellent agreement in total heat removal for the near pseudocritical region, as well as regions where carbon dioxide is a high or low density fluid.


2017 ◽  
Vol 139 (6) ◽  
Author(s):  
Jiangfeng Guo ◽  
Xiulan Huai

A printed circuit heat exchanger (PCHE) was selected as the recuperator of supercritical carbon dioxide (S-CO2) Brayton cycle, and the segmental design method was employed to accommodate the rapid variations of properties of S-CO2. The local heat capacity rate ratio has crucial influences on the local thermal performance of PCHE, while having small influences on the frictional entropy generation. The heat transfer entropy generation is far larger than the frictional entropy generation, and the total entropy generation mainly depends on the heat transfer entropy generation. The axial conduction worsens the thermal performance of PCHE, which becomes more and more obvious with the increase of the thickness and thermal conductivity of plate. The evaluation criteria, material, and size of plate have to be selected carefully in the design of PCHE. The present work may provide a practical guidance on the design and optimization of PCHE when S-CO2 is employed as working fluid.


Author(s):  
Anton V. Moisseytsev ◽  
James J. Sienicki ◽  
David C. Wade

Recent development of the Secure Transportable Autonomous Reactor-Liquid Metal (STAR-LM) lead-cooled natural circulation fast reactor (LFR) has been directed at coupling to an advanced power conversion system that utilizes a gas turbine Brayton cycle with supercritical carbon dioxide (S-CO2) as the working fluid. A key ingredient in achieving a coupled plant having a high efficiency are the modular lead-to-CO2 heat exchangers that must fit within the available volume inside the reactor vessel and must heat the S-CO2 to a high temperature. Thermal hydraulic performance and feasibility of seven different heat exchanger concepts has been investigated with respect to the achievement of a suitably high Brayton cycle efficiency for the coupled LFR-S-CO2 plant. The relative merits of the different heat exchanger configurations are revealed by the analysis which provides a basis to select the most promising concepts for further development.


Author(s):  
Bongsu Choi ◽  
Junhyun Cho ◽  
Hyungki Shin ◽  
Jongjae Cho ◽  
Chulwoo Roh ◽  
...  

Abstract The supercritical carbon dioxide (S-CO2) power cycle has been a topic of interest because it exhibits a high efficiency and compact size and is compatible with any heat source. Since 2013, the Korea Institute of Energy Research (KIER) has developed three S-CO2 power cycle experimental test loops for distributed power source applications. Based on this experience, a hundreds of kWe-class dual Brayton test loop with a maximum temperature of 500 °C has been designed and partially fabricated. This cycle consists of two turbines, one compressor, two recuperators, and a flued-gas heater. First, a relatively low-temperature turbine with an inlet temperature of 392 °C was designed and manufactured as an axial impulsetype turbo-generator because of the cost and development time required for construction of a full-cycle test loop. As a preliminary step, the turbo-generator was successfully tested in 2017. Next, it was continuously operated for 4.2 h in 2018. In addition, the following components were designed and manufactured: a centrifugal compressor with a dry gas seal; oil-lubricated tilting-pad bearings; a flued-gas heater, which consists of a burner and a shell-and-tube heat exchanger; and two printed circuit heat exchanger type recuperators. The full cycle is expected to be operational in November 2019.


2019 ◽  
Vol 8 (4) ◽  
pp. 2704-2712

The refrigerants are usually provided in the conventional refrigeration system despite the fact that, they produce CFCs and HCFCs, which are hazardous to the environment. However, these disadvantages can be overcome using air or inert gas in the thermoacoustic refrigeration system. The present research involves the effect of spacing of parallel plate stack on the performance of thermoacoustic refrigerator (TAR) in terms of temperature difference (∆T). The entire resonator system as well as other structural parts of the refrigerator are fabricated by using PVC to reduce conduction heat loss. Three parallel plate stacks have been used to study the performance of TAR considering different porosity ratios by varying the gap between the parallel plates (0.28 mm, 0.33 mm and 0.38 mm). The parallel plate stacks are fabricated by using aluminium and mylar sheet material and the working fluid used for the experimental study is helium. The experiments have been carried out with different drive ratios ranging from 0.6% to 1.6% with operating frequencies of 200 – 600 Hz. Also the mean operating pressure used for the experiment is 2 to 10 bar and cooling load of 2 to 10W are considered. The ∆T between the hot heat exchanger and cold heat exchanger is recorded using RTDs and Bruel and Kjaer data acquisition system. Experimental results shows that the lowest temperature measured at cold heat exchanger is -2.1 oC by maintaining the hot heat exchanger temperature at about 32 oC. The maximum temperature difference of 32.90 oC is achieved.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Alan Kruizenga ◽  
Hongzhi Li ◽  
Mark Anderson ◽  
Michael Corradini

Competitive cycles must have a minimal initial cost and be inherently efficient. Currently, the supercritical carbon dioxide (S-CO2) Brayton cycle is under consideration for these very reasons. This paper examines one major challenge of the S-CO2 Brayton cycle: the complexity of heat exchanger design due to the vast change in thermophysical properties near a fluid’s critical point. Turbulent heat transfer experiments using carbon dioxide, with Reynolds numbers up to 100 K, were performed at pressures of 7.5–10.1 MPa, at temperatures spanning the pseudocritical temperature. The geometry employed nine semicircular, parallel channels to aide in the understanding of current printed circuit heat exchanger designs. Computational fluid dynamics was performed using FLUENT and compared to the experimental results. Existing correlations were compared, and predicted the data within 20% for pressures of 8.1 MPa and 10.2 MPa. However, near the critical pressure and temperature, heat transfer correlations tended to over predict the heat transfer behavior. It was found that FLUENT gave the best prediction of heat transfer results, provided meshing was at a y+ ∼ 1.


Sign in / Sign up

Export Citation Format

Share Document