scholarly journals Investigation of Shroud Geometry to Passively Improve Heat Transfer in a Solar Thermal Storage Tank

2013 ◽  
Vol 136 (1) ◽  
Author(s):  
Matthew K. Zemler ◽  
Sandra K. S. Boetcher

A shroud and baffle configuration is used to passively increase heat transfer in a thermal store. The shroud and baffle are used to create a vena contracta near the surface of the heat exchanger, which will speed up the flow locally and thereby increasing heat transfer. The goal of this study is to investigate the geometry of the shroud in optimizing heat transfer by locally increasing the velocity near the surface of the heat exchanger. Two-dimensional transient simulations are conducted. The immersed heat exchanger is modeled as an isothermal cylinder, which is situated at the top of a solar thermal storage tank containing water (Pr = 3) with adiabatic walls. The shroud and baffle are modeled as adiabatic, and the geometry of the shroud and baffle are parametrically varied. Nusselt numbers and fractional energy discharge rates are obtained for a range of Rayleigh numbers, 105 ≤ RaD ≤ 107 in order to determine optimal shroud and baffle configurations. It was found that a baffle width of 75% of the width of the heat exchanger provided the best heat transfer performance.

Author(s):  
S. K. S. Boetcher ◽  
F. A. Kulacki

Enhancing heat transfer during the charge and discharge of solar thermal storage tanks is an ongoing technical challenge. The types of thermal storage systems considered in the present study comprise an immersed heat exchanger at the top of a solar thermal storage fluid. The discharge process of a thermal store with specified dimensions is numerically simulated over a range of Rayleigh numbers, 105 < RaD <107. The immersed heat exchanger is modeled as a two-dimensional isothermal cylinder which is situated near the top of a water-filled tank with adiabatic walls. An adiabatic shroud whose shape is parametrically varied is placed around the cylinder. In addition, the shroud is connected to an adiabatic baffle situated beneath the cylinder. Nusselt numbers are calculated for different shroud shapes at different Rayleigh numbers. Results show that the shroud is effective in increasing the heat transfer rate. Optimal shroud and baffle geometries are presented as well as qualitative flow results.


Author(s):  
S. K. S. Boetcher ◽  
F. A. Kulacki ◽  
Jane H. Davidson

Optimizing heat transfer during the charge and discharge of thermal stores is crucial for high performance of solar thermal systems for domestic and commercial applications. This study models a sensible water storage tank for which charge and discharge are accomplished using a heat exchanger immersed in the storage fluid. The objective is to investigate the use of a baffle and shroud as a means to improve convective heat transfer and thermal stratification. The immersed heat exchanger is modeled as a two-dimensional isothermal cylinder which is situated near the top of a storage tank with adiabatic walls. Transient numerical simulations of the discharge process are obtained for 105 < RaD < 107. An adiabatic shroud and baffle whose geometry is parametrically varied is placed around and below the cylinder. Transient Nusselt numbers are calculated for different baffle-shroud geometries and Rayleigh numbers. Results indicate that a long baffle with a high shroud height is optimal.


Author(s):  
Xiangbo Kong ◽  
Yuan Fu ◽  
Jianyu Zhang ◽  
Huiju Lu ◽  
Naxiu Wang

A FLiNaK high temperature test loop, which was designed to support the Thorium Molten Salt Reactor (TMSR) program, was constructed in 2012 and is the largest engineering-scale fluoride loop in the world. The loop is built of Hastelloy C276 and is capable of operating at the flow rate up to 25m3/h and at the temperature up to 650°C. It consists of an overhung impeller sump-type centrifugal pump, an electric heater, a heat exchanger, a freeze valve and a mechanical one, a storage tank, etc. Salt purification was conducted in batch mode before it was transferred to and then stored in the storage tank. The facility was upgraded in three ways last year, with aims of testing a 30kW electric heater and supporting the heat transfer experiment in heat exchanger. Firstly, an original 100kW electric heater was replaced with a 335kW one to compensate the overlarge heat loss in the radiator. A pressure transmitter was subsequently installed in the inlet pipe of this updated heater. Finally, a new 30kW electric heater was installed between the pump and radiator, the purpose of which was to verify the core’s convective heat transfer behavior of a simulator design of TMSR. Immediately after these above works, shakedown test of the loop was carried out step by step. At first the storage tank was gradually preheated to 500°C so as to melt the frozen salt. Afterwards, in order to make the operation of transferring salt from storage tank to loop achievable, the loop system was also preheated to a relatively higher temperature 530°C. Since the nickel-base alloy can be severely corroded by the FLiNaK salt once the moisture and oxygen concentration is high, vacuum pumping and argon purging of the entire system were alternatively performed throughout the preheating process, with the effect of controlling them to be lower than 100ppm. Once the salt was transferred into the loop, the pump was immediately put into service. At the very beginning of operation process, it was found that flow rate in the main piping could not be precisely measured by the ultrasonic flow meter. Ten days later, the pump’s dry running gas seal was out of order. As a result, the loop had to be closed down to resolve these issues.


Author(s):  
Maritza Ruiz ◽  
Van P. Carey

The energy conversion effectiveness of the central receiver absorber in concentrating solar thermal power systems is dictated primarily by heat losses, material temperature limits, and pumping power losses. To deliver concentrated solar energy to a gas for process heat applications or gas cycle power generation, there are a wide variety of compact heat exchanger finned surfaces that could be used to enhance the convective transfer of absorbed solar energy to the gas stream flowing through the absorber. In such circumstances, a key design objective for the absorber is to maximize the heat transfer thermodynamic performance while minimizing the pumping power necessary to drive the gas flow through the fin matrix. This paper explores the use of different performance metrics to quantify the combined heat transfer, thermodynamic and pressure loss effectiveness of enhanced fins surfaces used in solar thermal absorbers for gas heating. Previously defined heat exchanger performance metrics, such as the “goodness factor”, are considered, and we develop and explore the use of a new metric, the “loss factor”, for determining the preferred enhanced fin matrix surfaces for concentrated solar absorbers. The loss factor, defined as the normalized exergy loss in the receiver, can be used for nondimensional analysis of the desirable qualities in an optimized solar receiver design. In comparison to previous goodness factor methods, the loss factor metric has the advantage that it quantifies the trade-off between trying to maximize the solar exergy transferred to the gas (high heat transfer rate and delivery at high temperature) and minimizing the pumping exergy loss. In this study, the loss factor is used to compare current solar receiver designs, and designs that use a variety of available plate-finned compact heat transfer surfaces with known Colburn factor (j) and friction factor (f) characteristics. These examples demonstrate how the loss factor metric can be used to design and optimize novel solar central receiver systems, and they indicate fin matrix surfaces that are particularly attractive for this type of application.


Author(s):  
Banqiu Wu ◽  
Ramana G. Reddy ◽  
Robin D. Rogers

Abstract Feasibility of ionic liquids as liquid thermal storage media and heat transfer fluids in a solar thermal power plant was investigated. Many ionic liquids such as [C4min][PF6], [C8mim][PF6], [C4min][bistrifluromethane sulflonimide], [C4min][BF4], [C8mim][BF4], and [C4min][bistrifluromethane sulflonimide] were synthesized and characterized using thermogravimetric analysis (TGA), differential scanning calorimeter (DSC), nuclear magnetic resonance (NMR), viscometry, and some other methods. Properties such as decomposition temperature, melting point, viscosity, density, heat capacity, and thermal expansion coefficient were measured. The calculated storage density for [C8mim][PF6] is 378 MJ/m3 when the inlet and outlet field temperatures are 210°C and 390°C. For a single ionic liquid, [C4mim][BF4], the liquid temperature range is from −75°C to 459°C. It is found that ionic liquids have advantages of high density, wide liquid temperature range, low viscosity, high chemical stability, non-volatility, high heat capacity, and high storage density. Based on our experimental results, it is concluded that ionic liquids could be excellent liquid thermal storage media and heat transfer fluids in solar thermal power plant.


Author(s):  
M. R. Salem ◽  
K. M. Elshazly ◽  
R. Y. Sakr ◽  
R. K. Ali

The present work experimentally investigates the characteristics of convective heat transfer in horizontal shell and coil heat exchangers in addition to friction factor for fully developed flow through the helically coiled tube (HCT). The majority of previous studies were performed on HCTs with isothermal and isoflux boundary conditions or shell and coil heat exchangers with small ranges of HCT configurations and fluid operating conditions. Here, five heat exchangers of counter-flow configuration were constructed with different HCT-curvature ratios (δ) and tested at different mass flow rates and inlet temperatures of the two sides of the heat exchangers. Totally, 295 test runs were performed from which the HCT-side and shell-side heat transfer coefficients were calculated. Results showed that the average Nusselt numbers of the two sides of the heat exchangers and the overall heat transfer coefficients increased by increasing coil curvature ratio. The average increase in the average Nusselt number is of 160.3–80.6% for the HCT side and of 224.3–92.6% for the shell side when δ increases from 0.0392 to 0.1194 within the investigated ranges of different parameters. Also, for the same flow rate in both heat exchanger sides, the effect of coil pitch and number of turns with the same coil torsion and tube length is remarkable on shell average Nusselt number while it is insignificant on HCT-average Nusselt number. In addition, a significant increase of 33.2–7.7% is obtained in the HCT-Fanning friction factor (fc) when δ increases from 0.0392 to 0.1194. Correlations for the average Nusselt numbers for both heat exchanger sides and the HCT Fanning friction factor as a function of the investigated parameters are obtained.


1992 ◽  
Vol 114 (3) ◽  
pp. 175-181 ◽  
Author(s):  
D. T. Reindl ◽  
W. A. Beckman ◽  
J. W. Mitchell

Many previously studied natural convection enclosure problems in the literature have the bounding walls of the enclosure responsible for driving the flow. A number of relevant applications contain sources within the enclosure which drive the fluid flow and heat transfer. The motivation for this work is found in solar thermal storage tanks with immersed coil heat exchangers. The heat exchangers provide a means to charge and discharge the thermal energy in the tank. The enclosure is cylindrical and well insulated. Initially the interior fluid is isothermal and quiescent. At time zero, a step change in the source temperature begins to influence the flow. The final condition is a quiescent isothermal fluid field at the source temperature. The governing time-dependent Navier-Stokes and energy equations for this configuration are solved by a finite element method. Solutions are obtained for 103≤RaD≤106. Scale analysis is used to obtain time duration estimates of three distinct heat transfer regimes. The transient heat transfer during these regimes are compared with limiting cases. Correlations are presented for the three regimes.


Author(s):  
Mauro Y. Fujikawa ◽  
Eduardo O. de A. Silva ◽  
Reinaldo A. das Neves ◽  
Derci Donizeti Massitelli ◽  
Newton Orlando Abraha˜o ◽  
...  

This work aims to present the results obtained from the experience gained through the accomplishment of the inspection with the ultrasonic umbilical pig in a non-piggable internal pipe buried in the Transpetro Storage Terminal in Sa˜o Caetano do Sul, in Sa˜o Paulo, Brazil. The pipeline considered in this work is a line for marine fuel oil, which, because of its high viscosity, must be heated in order to flow. The oil is heated in the terminal by the steam produced in boilers. The heat transfer may occur in a heat exchanger or inside the storage tank, and the pipeline referred is thermally isolated. So that the line could be inspected, it was divided in two parts, one upstream of the pumps (suction), which is a 12-inch line, and the other downstream of the same pumps (discharge), which is a 14-inch line. This work has been developed by Transpetro’s Pipeline Operation, Maintenance, Inspection and Safety Departments together, since the planning phase, passing by the job execution and getting to the conclusion. To begin with, the operational liberation of the line had to be agreed between all the departments involved with the PIG inspection, which were mentioned before, and Transpetro’s Logistics Department. Once the PIG passage was scheduled, an initial cleaning had to be performed by the Operation Activity. Since this line is non-piggable, the installation of adaptations was necessary. After that, the passage of cleaning PIGs was possible, and the line sections could be enabled. The next step was the inspection of the pipeline with umbilical ultrasonic PIGs. After the passage of these PIGs, the adaptations had to be removed and the pipeline had to be conditioned for the operational return. After this part of the inspection was finished, the verification of the results issued was necessary. Once the theoretical results were available, ditches were opened for correlation inspection and temporary repairs in the most critical points for the operation were applied. The last part of the work consists in an analysis study of technical and economical viability for rehabilitation of the lines.


Author(s):  
Wafaa Karaki ◽  
Peiwen Li ◽  
Jon Van Lew ◽  
M. M. Valmiki ◽  
Cholik Chan ◽  
...  

This paper presents an experimental study and analysis of the heat transfer of energy charge and discharge in a packed-bed thermocline thermal storage tank for application in concentrated solar thermal power plants. Because the energy storage efficiency is a function of many parameters including fluid and solid properties, tank dimensions, packing dimensions, and time lengths of charge and discharge, this paper aims to provide experimental data and a proper approach of data reduction and presentation. To accomplish this goal, dimensionless governing equations of energy conservation in the heat transfer fluid and solid packed-bed material are derived. The obtained experimental data will provide a basis for validation of mathematical models in the future.


Sign in / Sign up

Export Citation Format