Experimental Study of Linear and Radial Two-Phase Heat Transport Devices Driven by Electrohydrodynamic Conduction Pumping

2015 ◽  
Vol 137 (2) ◽  
Author(s):  
Matthew R. Pearson ◽  
Jamal Seyed-Yagoobi

Heat pipes are well known as simple and effective heat transport devices, utilizing two-phase flow and the capillary phenomenon to remove heat. However, the generation of capillary pressure requires a wicking structure and the overall heat transport capacity of the heat pipe is generally limited by the amount of capillary pressure generation that the wicking structure can achieve. Therefore, to increase the heat transport capacity, the capillary phenomenon must be either augmented or replaced by some other pumping technique. Electrohydrodynamic (EHD) conduction pumping can be readily used to pump a thin film of a dielectric liquid along a surface, using electrodes that are embedded into the surface. In this study, two two-phase heat transport devices are created. The first device transports the heat in a linear direction. The second device transports the heat in a radial direction from a central heat source. The radial pumping configuration provides several advantages. Most notably, the heat source is wetted with fresh liquid from all directions, thereby reducing the amount of distance that must be travelled by the working fluid. The power required to operate the EHD conduction pumps is a trivial amount relative to the heat that is transported.

Author(s):  
Matthew R. Pearson ◽  
Jamal Seyed-Yagoobi

Heat pipes are well-known as simple and effective heat transport devices, utilizing two-phase flow and the capillary phenomenon to remove heat. However, the generation of capillary pressure requires a wicking structure and the overall heat transport capacity of the heat pipe is generally limited by the amount of capillary pressure generation that the wicking structure can achieve. Therefore, to increase the heat transport capacity, the capillary phenomenon must be either augmented or replaced by some other pumping technique. Electro-hydrodynamic (EHD) conduction pumping has been demonstrated as an effective method for pumping liquid films by using DC electric fields and a dielectric working fluid. Beyond increased pumping capacity, EHD conduction pumping offers other advantages over capillary pumping, such as active control of the pumping capacity via the intensity of the applied electric field. This experimental study demonstrates the prospects of a macro-scale two-phase heat transport device that is driven by EHD conduction pumping. Various liquid film thicknesses are considered. In each case, the performance of the EHD-driven heat transport device at various electric field intensities is compared to the capabilities of the same device under gravity alone. The effect of tilt on the device is also considered.


Author(s):  
Viral K. Patel ◽  
Jamal Seyed-Yagoobi

Micro-scale two-phase flow heat transport involves specialized devices that are used to remove large amounts of heat from small surface areas. They operate by circulating a working fluid through a heated space which causes phase change from liquid to vapor. During this process, a significant amount of heat is transported away from the heat source. Micro-scale heat transport devices are compact in size and the heat transfer coefficient can be orders of magnitude higher than in macro-scale for similar operating conditions. Thus, it is of interest to develop such devices for cooling of next-generation electronics and other applications with extremely large heat fluxes. The heat transport device presented in this paper is driven by electrohydrodynamic (EHD) conduction pumping. In EHD conduction pumping, when an electric field is applied to a dielectric liquid, flow is induced. The pump is installed in a two-phase flow loop and has a circular 1 mm diameter cross section with electrode spacing on the order of 120 μm. It acts to circulate the fluid in the loop and has a simple yet robust, non-mechanical design. Results from two-phase flow experiments show that it is easily controlled and such electrically driven pumps can effectively be used in heat transport systems.


2018 ◽  
Vol 49 ◽  
pp. 00020 ◽  
Author(s):  
Michal Duda ◽  
Jurij Dobrianski ◽  
Daniel Chludzinski

Devices called reverse thermosyphon enable passive heat transfer when the heat source is above the place of its receipt. This is often the case in solar installations for the preparation of hot water. The article concerns the determination of the possibility of using a two-phase inverted thermosyphon with two working factors in a passive downwards heat transport installation. The analysis was carried out on the basis of previous experimental studies. The height of the tested installation in one case was 1.5 m, in the second 18 m, at a heat load of 300, 600 and 900 W. Water and pentane was used as a working fluid inside the loop. Initial conclusions from the analysis confirm the possibility of using reverse thermosyphon with two working factors in the construction of a passive heat transport system.


Author(s):  
Sukhvinder Kang ◽  
Randy Cook ◽  
Dave Gailus

In recent years heat pipes have become widely use in high performance air-cooled heat sinks for cooling electronics equipment. Such heat sinks rely on the heat pipes to collect heat from small high heat flux sources, transport it over some distance, and spread the heat efficiently to a volume of fins where the heat is transferred to an air flow stream by convection. When used effectively, heat pipes enable heat sinks that have low thermal resistance and low mass. For the heat sink to be successful, the heat pipes must also have sufficient heat transport capacity. To deliver their design thermal resistance and heat transport capacity, heat pipes need to be manufactured with well-controlled wick characteristics, working fluid fill volume and minimal residual non-condensable gases. It is standard procedure for heat pipe manufacturing companies to test 100 percent of the heat pipes they manufacture. The most commonly used production test is designed to rapidly show whether or not a heat pipe functions as a heat pipe. On a sampling basis, manufacturers also test the heat transport capacity of their heat pipes. There is no rapid test that can verify that any specific heat pipe will achieve the desired operational life — this is achieved by validation of the manufacturing process and adequate manufacturing process controls. In this paper we describe a test method and apparatus that can be used to rapidly test whether a heat pipe has the required thermal resistance at the specified heat transport capacity. The apparatus is capable of testing heat pipes over a wide range of diameters and lengths in their end use configuration (with bends and flattened regions). The key design criteria for the test apparatus is described and test data for several application specific heat pipes is presented.


Author(s):  
Takahiro Arai ◽  
Masahiro Kawaji ◽  
Yasushi Koito

A pulsating heat pipe (PHP) is a passive device with a good heat transport capability compared to other heat pipes. This paper describes an experimental investigation of a PHP with a serpentine channel fabricated by using a 3-D printer. The configuration of the flow channels in the PHP was close to that of commercially available PHPs made entirely of aluminum. To improve the heat transport capability and enable flow visualization, an aluminum plate was used on one side as the heat-transfer surface, on which transparent flow channels were fabricated by a 3-D printer and a polycarbonate filament. The interface between the aluminum plate and polycarbonate flow channel was cemented with a heat-resistant glue to ensure long term sealing. HFE-7000 was used as a working fluid. Oscillating two-phase flow in the PHP was observed with a high-speed digital video camera and transient surface temperatures at evaporator, insulator and condenser sections were measured by fine diameter thermocouples. The two-phase flow and thermal characteristics of the PHP at different heater power levels are presented.


Author(s):  
Matthew R. Pearson ◽  
Jamal Seyed-Yagoobi

Electrohydrodynamic (EHD) conduction pumping can be readily used to pump a thin film of a dielectric liquid along a surface, using electrodes that are embedded into the surface. This effect has been demonstrated under adiabatic conditions and has also been used to create a two-phase heat transport device that is similar to a heat pipe, but with the wicking structure replaced by an EHD conduction pump. In this study, a circular two-phase heat transport device is created. The device features circular electrodes that are arranged concentrically on the bottom surface and that pump a liquid film towards a heat source located at the center of the device. This heat source evaporates the liquid, and a large annular condenser at the periphery of the bottom surface provides a continuous supply of fresh liquid. This radial pumping configuration provides several advantages. Most notably, the heat source is wetted with fresh liquid from all 360 degrees, thereby reducing the amount of distance that must be travelled compared to a linear device. Consequently, the heat flux that can be removed from the central heat source far exceeds the normal critical heat flux of the working fluid. Electrodes are embedded in the condenser, adiabatic, and evaporator sections to maximize the amount of pumping head that can be generated and thereby maximize the heat flux removal.


1998 ◽  
Vol 120 (4) ◽  
pp. 1064-1071 ◽  
Author(s):  
J. M. Ha ◽  
G. P. Peterson

The original analytical model for predicting the maximum heat transport capacity in micro heat pipes, as developed by Cotter, has been re-evaluated in light of the currently available experimental data. As is the case for most models, the original model assumed a fixed evaporator region and while it yields trends that are consistent with the experimental results, it significantly overpredicts the maximum heat transport capacity. In an effort to provide a more accurate predictive tool, a semi-empirical correlation has been developed. This modified model incorporates the effects of the temporal intrusion of the evaporating region into the adiabatic section of the heat pipe, which occurs as the heat pipe approaches dryout conditions. In so doing, the current model provides a more realistic picture of the actual physical situation. In addition to incorporating these effects, Cotter’s original expression for the liquid flow shape factor has been modified. These modifications are then incorporated into the original model and the results compared with the available experimental data. The results of this comparison indicate that the new semiempirical model significantly improves the correlation between the experimental and predicted results and more accurately represents the actual physical behavior of these devices.