An Actuator Disk Model of Incidence and Deviation for RANS-Based Throughflow Analysis

2013 ◽  
Vol 136 (2) ◽  
Author(s):  
Simone Rosa Taddei ◽  
Francesco Larocca

Reynolds-averaged Navier–Stokes (RANS) equations with blade blockage and blade force source terms are solved in the meridional plane of complete axial flow turbomachinery using a finite-volume scheme. The equations of the compressible actuator disk (AD) are introduced to modify the evaluation of the convective fluxes at the leading and trailing edges (LEs and TEs). An AD behaves as a compact blade force which instantaneously turns the flow with no production of unphysical entropy. This avoids unphysical incidence loss across the LE discontinuity and allows for application of all of the desired deviation at the TE. Unlike previous treatments, the model needs no handmade modification of the throughflow (TF) surface and does not discriminate between inviscid and viscous meridional flows, which allows for coping with strong incidence gradients through the annulus wall boundary layers and with secondary deviation. This paper derives a generalized blade force term that includes the contribution of the LE and TE ADs in the divergence form of the TF equations and leads to generalized definitions of blade load, blade thrust, shaft torque, and shaft power. In analyzing a linear flat plate cascade with an incidence of 32 deg and a deviation of 21 deg, the proposed model provided a 105 reduction of unphysical total pressure loss compared to the numerical solution with no modeling. The computed mass flow rate, blade load, and blade thrust showed excellent agreement with the theoretical values. The complete RANS TF solver was used to analyze a four-stage turbine in design and off-design conditions with a spanwise-averaged incidence of up to 2 deg and 43 deg, respectively. Compared to a traditional streamline curvature solution, the RANS solution with incidence and deviation modeling provided a 0.1 to 0.7% accurate prediction of mass flow rate, shaft power, total pressure ratio, and adiabatic efficiency in both the operating conditions. It also stressed satisfactory agreement concerning the spanwise distributions of flow angle and Mach number at LEs and TEs. In particular, secondary deviation was effectively predicted. The RANS solution with no modeling showed acceptable performance prediction only in design conditions and could introduce no deviation.

2021 ◽  
Vol 312 ◽  
pp. 05001
Author(s):  
Edoardo Di Mattia ◽  
Agostino Gambarotta ◽  
Mirko Morini ◽  
Costanza Saletti

Refrigeration is an essential part of the food chain. It is used in all stages of the chain, from industrial food processing to final consumption at home. In these processes, mechanical refrigeration technologies are employed, where compressors increase gas pressure from evaporation to condensation. In industrial refrigeration systems, twin-screw compressors represent the most widely used technology. A detailed mathematical model of a twin-screw compressor has been developed in Simulink® using differential equations for energy and mass balances to simulate the compression cycle that includes suction, compression and discharge phases. Gas pressure and enthalpy can be calculated as time functions during the cycle. However, the computational times obtained limit the possibility to extend the use of the model in the development of control strategies for the whole refrigeration plant in its real operating conditions. Therefore, the detailed model has been used to train a simplified model developed in Matlab®: the simulated mass flow rate, shaft power and the fluid discharge temperature have been employed to identify several geometrical and thermodynamic parameters of the simplified model. The latter relies on non-linear algebraic equations and, thus, requires a very short computational time. A limited performance dataset has been used to train the model, and a different dataset to test it: the results of the models have been compared, and small errors in mass flow rate, shaft power and fluid discharge temperature have been observed.


Author(s):  
Yaping Liu ◽  
Xuefei Du ◽  
Xuyang Shi ◽  
Diangui Huang

This paper investigates spontaneous condensation of wet steam in a centrifugal turbine by means of three-dimensional computational fluid dynamics. The flow field and aerodynamic characteristics of the wet steam in the centrifugal turbine are compared and analyzed by using the equilibrium steam and nonequilibrium steam models, respectively, where the latter applies the classical droplet nucleation theory and neglects velocity slip between the liquid phase and the gaseous phase. The state parameters of wet steam are described here based on the IAPWS’97 formulation. It is concluded that under the design condition, the mass flow rate, wetness fraction, and flow angle of the wet steam centrifugal turbine in the nonequilibrium steam model all change compared with the equilibrium steam model, with values of 4.4%, 0.5%, and 10.57%, respectively. Then the performance variation of the wet steam centrifugal turbine is analyzed under different steam conditions and different outlet back-pressure conditions. The results show that the change law of the mass flow rate, shaft power, and wetness fraction in the centrifugal turbine are basically identical in both models, and the mass flow rate, shaft power, wheel efficiency, and entropy loss coefficient of the centrifugal turbine in the nonequilibrium steam model are all higher than those in the equilibrium steam model, whereas the outlet wetness fraction is lower than that in the equilibrium steam model.


2021 ◽  
Author(s):  
Rehan Khalid ◽  
Raffaele Luca Amalfi ◽  
Aaron P. Wemhoff

Abstract This paper introduces a novel thermal management solution coupling in-rack cooling and heat recovery system. System-level modeling capabilities are the key to design and analyze thermal performance for different applications. In this study, a semi-empirical model for a hermetically sealed scroll compressor is developed and applied to different scroll geometries. The model parameters are tuned and validated such that the model is applicable to a variety of working fluids. The identified parameters are split into two groups: one group is dependent on the compressor geometry and independent of working fluid, whereas the other group is fluid dependent. By modifying the fluid-dependent parameters using the specific heat ratios of two refrigerants, the model shows promise in predicting the refrigerant mass flow rate, discharge temperature and compressor shaft power of a third refrigerant. Here, the approach has been applied using data for two refrigerants (R22 and R134a) to achieve predictions for a third refrigerant’s (R407c) mass flow rate, discharge temperature, and compressor shaft power, with normalized root mean square errors of 0.01, 0.04 and 0.020, respectively. The normalization is performed based on the minimum and maximum values of the measured variable data. The technique thus presented in this study can be used to accurately predict the primary variables of interest for a scroll compressor running on a given refrigerant for which data may be limited, enabling component-level design or analysis for different operating conditions and system requirements.


2005 ◽  
Vol 127 (5) ◽  
pp. 1029-1037 ◽  
Author(s):  
L. O. Schunk ◽  
G. F. Nellis ◽  
J. M. Pfotenhauer

Growing interest in larger scale pulse tubes has focused attention on optimizing their thermodynamic efficiency. For Stirling-type pulse tubes, the performance is governed by the phase difference between the pressure and mass flow, a characteristic that can be conveniently adjusted through the use of inertance tubes. In this paper we present a model in which the inertance tube is divided into a large number of increments; each increment is represented by a resistance, compliance, and inertance. This model can include local variations along the inertance tube and is capable of predicting pressure, mass flow rate, and the phase between these quantities at any location in the inertance tube as well as in the attached reservoir. The model is verified through careful comparison with those quantities that can be easily and reliably measured; these include the pressure variations along the length of the inertance tube and the mass flow rate into the reservoir. These experimental quantities are shown to be in good agreement with the model’s predictions over a wide range of operating conditions. Design charts are subsequently generated using the model and are presented for various operating conditions in order to facilitate the design of inertance tubes for pulse tube refrigerators. These design charts enable the pulse tube designer to select an inertance tube geometry that achieves a desired phase shift for a given level of acoustic power.


Author(s):  
Brian M. T. Tang ◽  
Marko Bacic ◽  
Peter T. Ireland

This paper presents a computational investigation into the impact of cooling air injected through the stationary over-tip turbine casing on overall turbine efficiency. The high work axial flow turbine is representative of the high pressure turbine of a civil aviation turbofan engine. The effect of active modulation of the cooling air is assessed, as well as that of the injection locations. The influence of the through-casing coolant injection on the turbine blade over-tip leakage flow and the associated secondary flow features are examined. Transient (unsteady) sliding mesh simulations of a one turbine stage rotor-stator domain are performed using periodic boundary conditions. Cooling air configurations with a constant total pressure air supply, constant mass flow rate and actively controlled total pressure supply are assessed for a single geometric arrangement of cooling holes. The effects of both the mass flow rate of cooling air and the location of its injection relative to the turbine rotor blade are examined. The results show that all of the assessed cooling configurations provided a benefit to turbine row efficiency of between 0.2 and 0.4 percentage points. The passive and constant mass flow rate configurations reduced the over-tip leakage flow, but did so in an inefficient manner, with decreasing efficiency observed with increasing injection mass flow rate beyond 0.6% of the mainstream flow, despite the over-tip leakage mass flow rate continuing to reduce. By contrast, the active total pressure controlled injection provided a more efficient manner of controlling this leakage flow, as it permitted a redistribution of cooling air, allowing it to be applied in the regions close to the suction side of the blade tip which more directly reduced over-tip leakage flow rates and hence improved efficiency. Cooling air injected close to the pressure side of the rotor blade was less effective at controlling the leakage flow, and was associated with increased aerodynamic loss in the passage vortex.


2018 ◽  
Vol 8 (9) ◽  
pp. 1413 ◽  
Author(s):  
Dan Yao ◽  
Kwongi Lee ◽  
Minho Ha ◽  
Cheolung Cheong ◽  
Inhiug Lee

A new pump, called the hybrid airlift-jet pump, is developed by reinforcing the advantages and minimizing the demerits of airlift and jet pumps. First, a basic design of the hybrid airlift-jet pump is schematically presented. Subsequently, its performance characteristics are numerically investigated by varying the operating conditions of the airlift and jet parts in the hybrid pump. The compressible unsteady Reynolds-averaged Navier-Stokes equations, combined with the homogeneous mixture model for multiphase flow, are used as the governing equations for the two-phase flow in the hybrid pump. The pressure-based methods combined with the Pressure-Implicit with Splitting of Operators (PISO) algorithm are used as the computational fluid dynamics techniques. The validity of the present numerical methods is confirmed by comparing the predicted mass flow rate with the measured ones. In total, 18 simulation cases that are designed to represent the various operating conditions of the hybrid pump are investigated: eight of these cases belong to the operating conditions of only the jet part with different air and water inlet boundary conditions, and the remaining ten cases belong to the operating conditions of both the airlift and jet parts with different air and water inlet boundary conditions. The mass flow rate and the efficiency are compared for each case. For further investigation into the detailed flow characteristics, the pressure and velocity distributions of the mixture in a primary pipe are compared. Furthermore, a periodic fluctuation of the water flow in the mass flow rate is found and analyzed. Our results show that the performance of the jet or airlift pump can be enhanced by combining the operating principles of two pumps into the hybrid airlift-jet pump, newly proposed in the present study.


2021 ◽  
Vol 39 (4) ◽  
pp. 1225-1235
Author(s):  
Ajay K. Gupta ◽  
Manoj Kumar ◽  
Ranjit K. Sahoo ◽  
Sunil K. Sarangi

Plate-fin heat exchangers provide a broad range of applications in many cryogenic industries for liquefaction and separation of gasses because of their excellent technical advantages such as high effectiveness, compact size, etc. Correlations are available for the design of a plate-fin heat exchanger, but experimental investigations are few at cryogenic temperature. In the present study, a cryogenic heat exchanger test setup has been designed and fabricated to investigate the performance of plate-fin heat exchanger at cryogenic temperature. Major parameters (Colburn factor, Friction factor, etc.) that affect the performance of plate-fin heat exchangers are provided concisely. The effect of mass flow rate and inlet temperature on the effectiveness and pressure drop of the heat exchanger are investigated. It is observed that with an increase in mass flow rate effectiveness and pressure drop increases. The present setup emphasis the systematic procedure to perform the experiment based on cryogenic operating conditions and represent its uncertainties level.


2021 ◽  
Author(s):  
Raghuvaran D. ◽  
Satvik Shenoy ◽  
Srinivas G

Abstract Axial flow fans (AFF) are extensively used in various industrial sectors, usually with flows of low resistance and high mass flow rates. The blades, the hub and the shroud are the three major parts of an AFF. Various kinds of optimisation can be implemented to improve the performance of an AFF. The most common type is found to be geometric optimisation including variation in number of blades, modification in hub and shroud radius, change in angle of attack and blade twist, etc. After validation of simulation model and carrying out a grid independence test, parametric analysis was done on an 11-bladed AFF with a shroud of uniform radius using ANSYS Fluent. The rotational speed of the fan and the velocity at fan inlet were the primary variables of the study. The variation in outlet mass flow rate and total pressure was studied for both compressible and incompressible ambient flows. Relation of mass flow rate and total pressure with inlet velocity is observed to be linear and exponential respectively. On the other hand, mass flow rate and total pressure have nearly linear relationship with rotational speed. A comparison of several different axial flow tracks with the baseline case fills one of the research gaps.


Author(s):  
Dominik Schlüter ◽  
Robert P. Grewe ◽  
Fabian Wartzek ◽  
Alexander Liefke ◽  
Jan Werner ◽  
...  

Abstract Rotating stall is a non-axisymmetric disturbance in axial compressors arising at operating conditions beyond the stability limit of a stage. Although well-known, its driving mechanisms determining the number of stall cells and their rotational speed are still marginally understood. Numerical studies applying full-wheel 3D unsteady RANS calculations require weeks per operating point. This paper quantifies the capability of a more feasible quasi-2D approach to reproduce 3D rotating stall and related sensitivities. The first part of the paper deals with the validation of a numerical baseline the simplified model is compared to in detail. Therefore, 3D computations of a state-of-the-art transonic compressor are conducted. At steady conditions the single-passage RANS CFD matches the experimental results within an error of 1% in total pressure ratio and mass flow rate. At stalled conditions, the full-wheel URANS computation shows the same spiketype disturbance as the experiment. However, the CFD underpredicts the stalling point by approximately 7% in mass flow rate. In deep stall, the computational model correctly forecasts a single-cell rotating stall. The stall cell differs by approximately 21% in rotational speed and 18% in circumferential size from the experimental findings. As the 3D model reflects the compressor behaviour sufficiently accurate, it is considered valid for physical investigations. In the second part of the paper, the validated baseline is reduced in radial direction to a quasi-2D domain only resembling the compressor tip area. Four model variations regarding span-wise location and extent are numerically investigated. As the most promising model matches the 3D flow conditions in the rotor tip region, it correctly yields a single-cell rotating stall. The cell differs by only 7% in circumferential size from the 3D results. Due to the impeded radial migration in the quasi-2D slice, however, the cell exhibits an increased axial extent. It is assumed, that the axial expansion into the adjacent rows causes the difference in cell speed by approximately 24%. Further validation of the reduced model against experimental findings reveals, that it correctly reflects the sensitivity of circumferential cell size to flow coefficient and individual cell speed to compressor shaft speed. As the approach reduced the wall clock time by 92%, it can be used to increase the physical understanding of rotating stall at much lower costs.


Author(s):  
Nikhil M. Rao ◽  
Cengiz Camci

An experimental study of a turbine tip desensitization method based on tip coolant injection was conducted in a large-scale rotating turbine rig. One of twenty-nine rotor blades was modified and instrumented to have a tip trench with discrete injection holes directed towards the pressure side. Time accurate absolute total pressure was measured 0.3 chord lengths downstream of the rotor exit plane using a fast response dynamic pressure sensor in a phase-locked manner. The test cases presented include results for tip gap heights of 1.40% and 0.72% of the blade height, and coolant injection rates of 0.41%, 0.52%, 0.63%, and 0.72% core mass flow rate. At a gap height of 1.40% the leakage vortex is large, occupying about 15% blade span. A reduction in gap height causes the leakage vortex to reduce in size and move towards the blade suction side. The minimum total pressure measured, for the reduced gap, in the leakage vortex is about 4% greater. Coolant injection from the tip trench is successful in filling in the total pressure defect originally resulting from the leakage vortex without injection. At the higher tip injection rates the leakage vortex is also seen to have moved towards the blade tip. The high momentum associated with the tip jets affects the total pressure distributions in the neighboring passages.


Sign in / Sign up

Export Citation Format

Share Document