A Literature Review of Low Pressure Steam Turbine Exhaust Hood and Diffuser Studies

Author(s):  
Zoe Burton ◽  
Grant L. Ingram ◽  
Simon Hogg

This paper summarizes the findings from research studies carried out over the last 30 years, to better understand the flows in steam turbine low pressure exhaust hoods and diffusers. The work aims to highlight the areas where further study is still required. A detailed description of the flow structure is outlined and the influence of the last turbine stage and the hood geometry on loss coefficient is explored. At present, the key challenge faced is numerically modeling the three-dimensional, unsteady, transonic, wet steam exhaust hood flow given the impractically high computational power requirement. Multiple calculation simplifications to reduce the computational demand have been successfully verified with experimental data, but at present there is no ‘best-practice’ approach to reduce the computational time for routine design exercises. This paper highlights the importance of coupling the exhaust hood to the last stage steam turbine blades to capture the interaction; ensuring the total pressure and swirl angle profiles, along with the tip leakage jet are accurately applied to the diffuser inlet. The nonaxial symmetry of the exhaust hood means it is also important to model the full blade annulus. More studies have emerged modeling the wet steam and unsteady flow effects, but more work is required in this area to fully understand the impact on the flow structure.

Author(s):  
M. Häfele ◽  
J. Starzmann ◽  
M. Grübel ◽  
M. Schatz ◽  
D. M. Vogt ◽  
...  

A numerical study on the flow in a three stage low pressure industrial steam turbine with conical friction bolts in the last stage and lacing wires in the penultimate stage is presented and analyzed. Structured high-resolution hexahedral meshes are used for all three stages and the meshing methodology is shown for the rotor with friction bolts and blade reinforcements. Modern three-dimensional CFD with a non-equilibrium wet steam model is used to examine the aero-thermodynamic effects of the part-span connectors. A performance assessment of the coupled blades at part load, design and overload condition is presented and compared with measurement data from an industrial steam turbine test rig. Detailed flow field analyses and a comparison of blade loading between configurations with and without part-span connectors are presented in this paper. The results show significant interaction of the cross flow vortex along the part-span connector with the blade passage flow causing aerodynamic losses. This is the first time that part-span connectors are being analyzed using a non-equilibrium wet steam model. It is shown that additional wetness losses are induced by these elements.


Author(s):  
Zoe Burton ◽  
Simon Hogg ◽  
Grant L. Ingram

It has been widely recognized for some decades that it is essential to accurately represent the strong coupling between the last stage blades (LSB) and the diffuser inlet, in order to correctly capture the flow through the exhaust hoods of steam turbine low pressure cylinders. This applies to any form of simulation of the flow, i.e., numerical or experimental. The exhaust hood flow structure is highly three-dimensional and appropriate coupling will enable the important influence of this asymmetry to be transferred to the rotor. This, however, presents challenges as the calculation size grows rapidly when the full annulus is calculated. The size of the simulation means researchers are constantly searching for methods to reduce the computational effort without compromising solution accuracy. However, this can result in excessive computational demands in numerical simulations. Unsteady full-annulus CFD calculation will remain infeasible for routine design calculations for the foreseeable future. More computationally efficient methods for coupling the unsteady rotor flow to the hood flow are required that bring computational expense within realizable limits while still maintaining sufficient accuracy for meaningful design calculations. Research activity in this area is focused on developing new methods and techniques to improve accuracy and reduce computational expense. A novel approach for coupling the turbine last stage to the exhaust hood employing the nonlinear harmonic (NLH) method is presented in this paper. The generic, IP free, exhaust hood and last stage blade geometries from Burton et al. (2012. “A Generic Low Pressure Exhaust Diffuser for Steam Turbine Research,”Proceedings of the ASME Turbo Expo, Copenhagen, Denmark, Paper No. GT2012-68485) that are representative of modern designs, are used to demonstrate the effectiveness of the method. This is achieved by comparing results obtained with the NLH to those obtained with a more conventional mixing-plane approach. The results show that the circumferential asymmetry can be successfully transferred in both directions between the exhaust hood flow and that through the LSB, by using the NLH. This paper also suggests that for exhaust hoods of generous axial length, little change in Cp is observed when the circumferential asymmetry is captured. However, the predicted flow structure is significantly different, which will influence the design and placement of the exhaust hood internal “furniture.”


Author(s):  
Dickson Munyoki ◽  
Markus Schatz ◽  
Damian M. Vogt

Performance optimization of low pressure steam turbine exhaust hood has been a subject of a number of both numerical and experimental studies. This is driven by the understanding that improving the diffuser and exhaust hood outer casing performance results in a lower turbine back pressure and hence an increased plant overall output. The performance of the exhaust hood is greatly influenced by many structural factors such as the size of its outer casing, design of the diffuser parts and the arrangement of the internal supports. A number of studies have shown that a decrease of the hood height is detrimental to the exhaust hood performance [1, 2], however, up to now the impact of increased hood height has not been researched. In the present study, a scaled axial-radial diffuser test rig operated by ITSM is used as reference configuration for a parameter study. A total of fourteen different configurations with both increased and reduced hood height are investigated numerically. Design load at three different tip jet Mach numbers (no tip jet, tip jet Mach number of 0.4 and 1.2) is chosen as operating condition. Numerical and experimental data is available for the reference configuration and the numerical results have already been validated in a previous paper by the authors [3]. While a decrease of hood height shows the expected deterioration of efficiency, an increase of the hood height only initially results in an improved performance. After reaching a maximum efficiency, which is dependent on the tip leakage, the exhaust hood performance decreases noticeably again. Apart from the variation of pressure recovery, the results allow a better understanding of the loss mechanisms and flow phenomena in exhaust hoods, showing that the deflection of the flow coming out of the diffuser in the top part of the hood has a major impact on exhaust hood pressure recovery.


Author(s):  
Dickson Munyoki ◽  
Markus Schatz ◽  
Damian M. Vogt

The performance of the axial-radial diffuser downstream of the last low-pressure steam turbine stages and the losses occurring subsequently within the exhaust hood directly influences the overall efficiency of a steam power plant. It is estimated that an improvement of the pressure recovery in the diffuser and exhaust hood by 10% translates into 1% of last stage efficiency [11]. While the design of axial-radial diffusers has been the object of quite many studies, the flow phenomena occurring within the exhaust hood have not received much attention in recent years. However, major losses occur due to dissipation within vortices and inability of the hood to properly diffuse the flow. Flow turning from radial to downward flow towards the condenser, especially at the upper part of the hood is essentially the main cause for this. This paper presents a detailed analysis of the losses within the exhaust hood flow for two operating conditions based on numerical results. In order to identify the underlying mechanisms and the locations where dissipation mainly occurs, an approach was followed, whereby the diffuser inflow is divided into different sectors and pressure recovery, dissipation and finally residual kinetic energy of the flow originating from these sectors is calculated at different locations within the hood. Based on this method, the flow from the topmost sectors at the diffuser inlet is found to cause the highest dissipation for both investigated cases. Upon hitting the exhaust hood walls, the flow on the upper part of the diffuser is deflected, forming complex vortices which are stretching into the condenser and interacting with flow originating from other sectors, thereby causing further swirling and generating additional losses. The detailed study of the flow behavior in the exhaust hood and the associated dissipation presents an opportunity for future investigations of efficient geometrical features to be introduced within the hood to improve the flow and hence the overall pressure recovery coefficient.


2017 ◽  
Vol 139 (7) ◽  
Author(s):  
Luying Zhang ◽  
Francesco Congiu ◽  
Xiaopeng Gan ◽  
David Karunakara

The performance of the radial diffuser of a low pressure (LP) steam turbine is important to the power output of the turbine. A reliable and robust prediction and optimization tool is desirable in industry for preliminary design and performance evaluation. This is particularly critical during the tendering phase of retrofit projects, which typically cover a wide range of original equipment manufacturer and other original equipment manufacturers designs. This work describes a fast and reliable numerical approach for the simulation of flow in the last stage and radial diffuser coupled with the exhaust hood. The numerical solver is based on a streamline curvature throughflow method and a geometry-modification treatment has been developed for off-design conditions, at which large-scale flow separation may occur in the diffuser domain causing convergence difficulty. To take into account the effect of tip leakage jet flow, a boundary layer solver is coupled with the throughflow calculation to predict flow separation on the diffuser lip. The performance of the downstream exhaust hood is modeled by a hood loss model (HLM) that accounts for various loss generations along the flow paths. Furthermore, the solver is implemented in an optimization process. Both the diffuser lip and hub profiles can be quickly optimized, together or separately, to improve the design in the early tender phase. 3D computational fluid dynamics (CFD) simulations are used to validate the solver and the optimization process. The results show that the current method predicts the diffuser/exhaust hood performance within good agreement with the CFD calculation and the optimized diffuser profile improves the diffuser recovery over the datum design. The tool provides General Electric the capability to rapidly optimize and customize retrofit diffusers for each customer considering different constraints.


Author(s):  
Zoe Burton ◽  
Grant Ingram ◽  
Simon Hogg

The exhaust hood of a steam turbine is a vital area of turbomachinery research its performance strongly influences the power output of the last stage blades. It is well known that accurate CFD simulations are only achieved when the last stage blades are coupled to the exhaust hood to capture the strong interaction. This however presents challenges as the calculation size grows rapidly when the full annulus is calculated. The size of the simulation means researchers are constantly searching of methods to reduce the computational effort without compromising solution accuracy. This work uses a novel approach, by coupling the last stage blades and exhaust hood by the Non-Linear Harmonic Method, a technique widely used to reduce calculation size in high pressure turbine blades and axial compressors. This has been benchmarked against the widely adopted Mixing Plane method. The test case used is the Generic Geometry, a representative exhaust hood and last stage blade geometry that is free from confidentiality and IP restrictions and for which first calculations were presented at last year’s conference [1]. The results show that the non-uniform exhaust hood inlet flow can be captured using the non-liner harmonic method, an effect not previously achievable with single passage coupled calculations such as the mixing plane approach. This offers a significant computational saving, estimated to be a quarter of the computation time compared with alternative methods of capturing the asymmetry with full annulus frozen rotor calculations.


Author(s):  
Michal Hoznedl ◽  
Antonín Živný ◽  
Aleš Macálka ◽  
Robert Kalista ◽  
Kamil Sedlák ◽  
...  

The paper presents the results of measurements of flow parameters behind the last stage of a 1090 MW nominal power steam turbine in a nuclear power plant. The results were obtained by traversing a pneumatic probe at a distance of about 100 mm from the trailing edges of the LSB (Last Stage Blade). Furthermore, both side walls as well as the front wall of one flow of the LP (Low Pressure) exhaust hood were fitted with a dense net of static pressure taps at the level of the flange of the turbine. A total of 26 static pressures were measured on the wall at the output from the LP exhaust hood. Another 14 pressures were measured at the output from the condenser neck. The distribution of static pressures in both cross sections for full power and 600 and 800 MW power is shown. Another experiment was measured pressure and angle distribution using a ball pneumatic probe in the condenser neck area in a total of four holes at a distance up to 5 metres from the neck wall. The turbine condenser is two-flow design. In one direction perpendicular to the axis of the turbine cold cooling water comes, it heats partially. It then reverses and it heats to the maximum temperature again. The different temperature of cooling water in the different parts of the output cross section should influence the distribution of the output static pressure. Differences in pressures may cause problems with uneven load of the tube bundles of the condenser as well as problems with defining the influential edge output condition in CFD simulations of the flow of the cold end of the steam turbine Due to these reasons an extensive 3D CFD computation, which includes one stator blade as well as all moving blades of the last stage, a complete diffuser, the exhaust hood and the condenser neck, has been carried out. Geometry includes all reinforcing elements, pipes and heaters which could influence the flow behaviour in the exhaust hood and its pressure loss. Inlet boundary conditions were assumed for the case of both computations from the measurement of the flow field behind the penultimate stage. The outlet boundary condition was defined in the first case by an uneven value of the static pressure determined by the change of the temperature of cooling water. In the second case the boundary condition in accordance with the measurement was defined by a constant value of the static pressure along all the cross section of the output from the condenser neck. Results of both CFD computations are compared with experimental measurement by the distribution of pressures and other parameters behind the last stage.


Author(s):  
Joerg Schuerhoff ◽  
Andrei Ghicov ◽  
Karsten Sattler

Blades for low pressure steam turbines operate in flows of saturated steam containing water droplets. The water droplets can impact rotating last stage blades mainly on the leading edge suction sides with relative velocities up to several hundred meters per second. Especially on large blades the high impact energy of the droplets can lead to a material loss particularly at the inlet edges close to the blade tips. This effect is well known as “water droplet erosion”. The steam turbine manufacturer use several techniques, like welding or brazing of inlays made of erosion resistant materials to reduce the material loss. Selective, local hardening of the blade leading edges is the preferred solution for new apparatus Siemens steam turbines. A high protection effect combined with high process stability can be ensured with this Siemens hardening technique. Furthermore the heat input and therewith the geometrical change potential is relatively low. The process is flexible and can be adapted to different blade sizes and the required size of the hardened zones. Siemens collected many years of positive operational experience with this protection measure. State of the art turbine blades often have to be developed with precipitation hardening steels and/or a shroud design to fulfill the high operational requirements. A controlled hardening of the inlet edges of such steam turbine blades is difficult if not impossible with conventional methods like flame hardening. The Siemens steam turbine factory in Muelheim, Germany installed a fully automated laser treatment facility equipped with two co-operating robots and two 6 kW high power diode laser to enable the in-house hardening of such blades. Several blade designs from power generation and industrial turbines were successfully laser treated within the first year in operation. This paper describes generally the setup of the laser treatment facility and the application for low pressure steam turbine blades made of precipitation hardening steels and blades with shroud design, including the post laser heat treatments.


Author(s):  
Peter Stein ◽  
Dirk Telschow ◽  
Frederic Lamarque ◽  
Nuncio Colitto

Since many years the diffuser and exhaust of low pressure (LP) turbines have been in the focus of turbine development and accordingly broadly discussed within the scientific community. The pressure recovery gained within the diffuser significantly contributes to the turbine performance and therefore plenty of care is taken in investigations of the flow as well as optimization within this part of the turbine. However on a plant level the component following the LP turbine is the condenser, which is connected by the condenser neck. Typically the condenser neck is not fully designed to provide additional enthalpy recovery. Due to plant arrangement reasons, often it is full of built-ins like stiffening struts, feed-water heaters, extraction pipes, steam dump devices and others. It is vital to minimize the pressure losses across the condenser neck, in order to keep performance benefit, previously gained within the diffuser. As a general rule, each mbar of total pressure loss in a condenser neck may reduce the gross power output up to 0.1%. While turbines usually follow a modular approach, the condenser is typically designed plant specific. Therefore, on a plant level it is crucial to identify and evaluate the loss contributors and develop processes and tools which allow an accurate and efficient design process for an optimized condenser neck design. This needs to be performed as a coupled modelling approach, as both, turbine and condenser flow interact with each other. 3-D CFD tools enable a deep insight into the flow field and help to locally optimize the design, as they help to identify local losses and this even for small geometrical design changes. Unfortunately these tools are costly with respect to computational time and resources, if they are used to analyze a full condenser neck with all built-ins. Here 1-D modelling approaches can help to close the gap, as they can provide fast feedback, e.g. in a project tender phase, or can allow to quickly analyze design changes. For this they need a proper calibration and validation. This publication discusses the CFD modelling of a LP steam turbine coupled to a condenser neck and the validity of such calculations against measurement data. In the second publication (Part 2) a simplification of the gained information to a 1-D modelling approach will be discussed.