scholarly journals Optimum Jet-to-Plate Spacing of Inline Impingement Heat Transfer for Different Crossflow Schemes

2013 ◽  
Vol 135 (7) ◽  
Author(s):  
Yunfei Xing ◽  
Bernhard Weigand

A nine-by-nine jet array impinging on a flat plate at Reynolds numbers from 15,000 to 35,000 has been studied by the transient liquid crystal method. The spacing between the impingement plate and target plate is adjusted to be 1, 2, 3, 4, and 5 jet diameters. The effect of jet-to-plate spacing has been investigated for three jet-induced crossflow schemes, referred as minimum, medium, and maximum crossflow, correspondingly. The local air jet temperature is measured at several positions on the impingement plate to account for an appropriate reference temperature of the heat transfer coefficient. The jet-to-plate spacing, H/d = 3, is found to be better than the others for all the crossflow schemes. Jet-to-plate spacings H/d = 1 and H/d = 2 result in a sudden decrease in the stagnation zone. The large jet-to-plate spacings H/d = 4 and H/d = 5 could not provide higher heat transfer performance with higher crossflow.

Author(s):  
Yunfei Xing ◽  
Bernhard Weigand

A nine-by-nine staggered jet array impinging on a flat or rib roughened plate at Reynolds numbers from 15,000 to 35,000 has been studied by the transient liquid crystal method. The jet-to-plate spacings are adjusted to be 3, 4 and 5 jet diameters. Three jet-induced crossflow schemes, referred as minimum, medium and maximum crossflow correspondingly, have been measured. The local air jet temperature is measured at several positions on the impingement plate to account for an appropriate reference temperature of the heat transfer coefficient. The heat transfer results of the rib roughened plate are compared with those of the flat plate. The best heat transfer performance is obtained with the minimum crossflow and narrow jet-to-plate spacing no matter on a flat or roughened plate. The presence of rib turbulators on the target plate produce higher heat transfer coefficients than the flat plate for narrow jet-to-plate spacing by 7.5%. Note that this value is within the measurement uncertainty of 9%.


Author(s):  
Kyo Sung Choo ◽  
Sung Jin Kim

Heat transfer characteristics of an impinging air jet are experimentally investigated under a fixed pumping power condition. The effects of dimensionless pumping power on the Nusselt number are considered. The focus is on cases where the nozzle-to-plate spacing is equal to or less than one nozzle diameter. The results show that the Nusselt number is independent of the nozzle-to-plate spacing under fixed pumping power conditions, while the Nusselt number increases with decreasing the nozzle-to-plate spacing under fixed flow rate conditions. Based on the experimental results, new correlations for the stagnation and average Nusselt numbers of the impinging jet are developed as a function of the pumping power alone.


2014 ◽  
Vol 663 ◽  
pp. 322-328 ◽  
Author(s):  
Ali Ahmed Gitan ◽  
Rozli Zulkifli ◽  
Kamaruzaman Sopian ◽  
Shahrir Abdullah

The problem of environmental pollution and depletion of fossil fuel can be reduced in automotives by using an alternative bio-fuel and improve the ignition process in engine. Both solutions need to use the fuel preheating technique. This work presents the idea of fuel preheating by using exhaust impingement on the fuel tank. Heat transfer between twin pulsating hot air jets and flat copper target was investigated as an application for preheating of automotive fuel to improve ignition process in the engine. The nozzle of 20 mm was used to produce air jet of Reynolds number, Re ≃ 5500 and a temperature of 54°C. The impinged target was imposed to still air surrounding at temperature of 24°C. Pulsating frequencies of 10-50 Hz were applied on air jets by using twin pulsating jet mechanism. The effect of pulsation frequency on heat transfer was measured using IR camera and heat flux-temperature micro foil sensor. The results obtained by both of these methods showed well agreement. Also, the results revealed significant influence of flow rate difference between steady and pulsating jet cases. In addition, the highest Nusselt number, Nu ≃ 7.2, was obtained at pulsation frequency of 20 Hz.


Author(s):  
Fatih Selimefendigil ◽  
Hakan F. Oztop

Abstract Nanoliquid impingement heat transfer with phase change material (PCM) installed radial system is considered. Study is performed by using finite element method for various values of Reynolds numbers (100 ≤ Re ≤ 300), height of PCM (0.25H ≤ hpcm = 0.7H ≤ 0.75H) and plate spacing (0.15H ≤ hpcm = 0.7H ≤ 0.40H). Different configurations with using water, nanoliquid and nanoliquid+PCM are compared in terms of heat transfer improvement. Thermal performance is improved by using PCM while best performance is achieved with nanoliquid and PCM installed configuration. At Re=100 and Re=300, heat transfer improvements of 26% and 25.5% are achieved with nanoliquid+PCM system as compared to water without PCM. Height of the PCM layer also influences the heat transfer dynamic behavior while there is 12.6% variation in the spatial average heat transfer of the target surface with the lowest and highest PCM height while discharging time increases by about 76.5%. As the spacing between the plates decreases, average heat transfer rises and there is 38% variation.


Author(s):  
Patricia Streufert ◽  
Terry X. Yan ◽  
Mahdi G. Baygloo

Local turbulent convective heat transfer from a flat plate to a circular impinging air jet is numerically investigated. The jet-to-plate distance (L/D) effect on local heat transfer is the main focus of this study. The eddy viscosity V2F turbulence model is used with a nonuniform structured mesh. Reynolds-Averaged Navier-Stokes equations (RANS) and the energy equation are solved for axisymmetric, three-dimensional flow. The numerical solutions obtained are compared with published experimental data. Four jet-to-plate distances, (L/D = 2, 4, 6 and 10) and seven Reynolds numbers (Re = 7,000, 15,000, 23,000, 50,000, 70,000, 100,000 and 120,000) were parametrically studied. Local and average heat transfer results are analyzed and correlated with Reynolds number and the jet-to-plate distance. Results show that the numerical solutions matched experimental data best at low jet-to-plate distances and lower Reynolds numbers, decreasing in ability to accurately predict the heat transfer as jet-to-plate distance and Reynolds number was increased.


2019 ◽  
Vol 141 (8) ◽  
Author(s):  
Chunkyraj Khangembam ◽  
Dushyant Singh

Experimental investigation on heat transfer mechanism of air–water mist jet impingement cooling on a heated cylinder is presented. The target cylinder was electrically heated and was maintained under the boiling temperature of water. Parametric studies were carried out for four different values of mist loading fractions, Reynolds numbers, and nozzle-to-surface spacings. Reynolds number, Rehyd, defined based on the hydraulic diameter, was varied from 8820 to 17,106; mist loading fraction, f ranges from 0.25% to 1.0%; and nozzle-to-surface spacing, H/d was varied from 30 to 60. The increment in the heat transfer coefficient with respect to air-jet impingement is presented along with variation in the heat transfer coefficient along the axial and circumferential direction. It is observed that the increase in mist loading greatly increases the heat transfer rate. Increment in the heat transfer coefficient at the stagnation point is found to be 185%, 234%, 272%, and 312% for mist loading fraction 0.25%, 0.50%, 0.75%, and 1.0%, respectively. Experimental study shows identical increment in stagnation point heat transfer coefficient with increasing Reynolds number, with lowest Reynolds number yielding highest increment. Stagnation point heat transfer coefficient increased 263%, 259%, 241%, and 241% as compared to air-jet impingement for Reynolds number 8820, 11,493, 14,166, and 17,106, respectively. The increment in the heat transfer coefficient is observed with a decrease in nozzle-to-surface spacing. Stagnation point heat transfer coefficient increased 282%, 248%, 239%, and 232% as compared to air-jet impingement for nozzle-to-surface spacing of 30, 40, 50, and 60, respectively, is obtained from the experimental analysis. Based on the experimental results, a correlation for stagnation point heat transfer coefficient increment is also proposed.


Author(s):  
Chadia Haidar ◽  
Rachid Boutarfa ◽  
Mohamed Sennoune ◽  
Souad Harmand

This work focuses on the numerical and experimental study of convective heat transfer in a rotor of a discoidal the machine with an eccentric impinging jet. Convective heat transfers are determined experimentally in steady state on the surface of a single rotating disk. The experimental technique is based on the use of infrared thermography to access surface temperature measurement, and on the numerical resolution of the energy equation in steady-state, to evaluate local convective coefficients. The results from the numerical simulation are compared with heat transfer experiments for rotational Reynolds numbers between 2.38×105 and 5.44×105 and for the jet's Reynolds numbers ranging from 16.5×103 to 49.6 ×103. A good agreement between the two approaches was obtained in the case of a single rotating disk, which confirms us in the choice of our numerical model. On the other hand, a numerical study of the flow and convective heat transfer in the case of an unconfined rotor-stator system with an eccentric air jet impinging and for a dimensionless spacing G=0.02, was carried out. The results obtained revealed the presence of different heat transfer zones dominated either by rotation only, by the air flow only or by the dynamics of the rotation flow superimposed on that of the air flow. Critical radii on the rotor surface have been identified


Volume 1 ◽  
2004 ◽  
Author(s):  
D. P. Mishra ◽  
D. Mishra

An experimental investigation of the impinging jet cooling from a heated flat plate has been carried out for several Reynolds numbers (Re) and nozzle to plate distances. The present results indicate that the maximum heat transfer occurs from the heated plate at stagnation point and decreases with radial distances for all cases. The maximum value of the stagnation as well as average Nusselt number is found to occur at separation distance, H/D = 6.0 for Re = 55000. An attempt is also made to study effects of nozzle exit configuration on the heat transfer using a sharp edged orifice for same set of Reynolds numbers and nozzle to plate distance. The stagnation Nusselt numbers of sharp orifice jets are found to be enhanced by around 16–21.4% in comparison to that of square edged orifice. However, the enhancement in the average Nusselt number of sharp orifice is found to be in the range of 7–18.9% as compared to the square edged orifice. The maximum enhancement of 18.9% in average Nu is achieved for Re = 55 000 at H/D = 6. Two separate correlations in terms of Nuo, Re, H/D for both square and sharp edged orifice are obtained which will be useful for designing impinging cooling system.


Author(s):  
Yasir M. Shariff ◽  
T. S. Ravigururajan

Experimental results from single-phase refrigerant mixture flow in smooth and micro-coil enhanced meso-channels are presented. R-407C — a mixture of R-32 (23%)/R-125 (25%)/R-134a (52%) — is used as the working fluid and different micro-coils are used in conjunction with two meso-channels (2.78mm and 3.97 mm) to obtain distinct roughness parameters. The flow was varied over a range of Reynolds numbers and experiments were conducted over a heat flux range of 2 to 11 kW/m2. The heat transfer coefficient was found to be dependent on both the heat flux as well as mass flux levels. Results show that heat transfer characteristics are comparable to R-113, and that micro-coil inserts enhanced the heat transfer performance compared to the performance in smooth meso-channels.


Author(s):  
Ryan Hebert ◽  
Srinath V. Ekkad ◽  
Vivek Khanna ◽  
Mario Abreu ◽  
Hee-Koo Moon

Impingement heat transfer is significantly affected by initial cross-flow or by the presence of cross-flow from upstream spent jets. In this study, a zero cross-flow design is presented. The zero-crossflow design creates spacing between hole arrays to allow for spent flow to be directed away from impinging jets. Three configurations with different impingement holes placements are studied and compared with pure impingement with spent crossflow cases for the same jet Reynolds number. Three jet Reynolds numbers are studied for Rej = 10000, 20000, and 30000. Detailed heat transfer distributions are obtained using the transient liquid crystal technique. The zero-cross flow design clearly shows minimal degradation of impingement heat transfer due to crossflow compared to conventional design with lower mass flow rate requirement and lesser number of overall impingement holes due to the reduced cross-flow effect on the impingement region.


Sign in / Sign up

Export Citation Format

Share Document