Study on the Reduction Strategy of Machining-Induced Edge Chipping Based on Finite Element Analysis of In-Process Workpiece Structure

Author(s):  
Hu Gong ◽  
F. Z. Fang ◽  
X. F. Zhang ◽  
Juan Du ◽  
X. T. Hu

Edge chipping is one of the most serious issues during machining process of brittle materials. To find an effective method to reduce edge chipping, the relationship between the distribution of maximum principal stress and edge chipping is studied comprehensively based on 3D finite element analysis (FEA) model of in-process workpiece structure in this paper. Three-level influencing factors of edge chipping are proposed, which are helpful to understand the relationship between intuitive machining parameters and edge chipping at different levels. Based on the analysis, several experiments are designed and conducted for drilling and slotting to study the strategy of controlling edge chipping. Two methods are adopted: (a) adding additional support, (b) improving tool path. The result show that edge chipping can be reduced effectively by optimizing the distribution of the maximum principal stress during the machining process. Further, adding addtitional support method is extended to more complex parts and also obtain a good result. Finally, how to use adding additional support method, especially for complex parts, will be discussed in detail. Several open questions are raised for future research.

2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Tarcisio José de Arruda Paes Junior ◽  
João Paulo Mendes Tribst ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Viviane Maria Gonçalves de Figueiredo ◽  
Alexandre Luiz Souto Borges ◽  
...  

Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain.   Keywords Finite element analysis; Occlusion; Total prosthesis.


2014 ◽  
Vol 15 (4) ◽  
pp. 444-450 ◽  
Author(s):  
César Dalmolin Bergoli ◽  
Rodrigo Furtado de Carvalho ◽  
Ivan Balducci ◽  
Josete Barbosa Cruz Meira ◽  
Maria Amélia Máximo de Araújo ◽  
...  

ABSTRACT Aim This study aims to evaluate, the influence of different fiber posts cementation lengths by finite element analysis (FEA) and coronal microleakage. Materials and methods Fifty anterior bovine teeth were sectioned to obtain roots with 16 mm length. The coronal length of the post was 6 mm for all groups, while the radicular length were varied 6, 8, 10 or 12 mm. The fiber posts surfaces were cleaned with alcohol and silanized. Then the posts were cemented using a two steps total etch-and-rinse adhesive system + conventional resin cement. Forty teeth were submitted to mechanical cycling (45°; 2.000.000 cycles; 90N; 4Hz; 37°C) and ten teeth with radicular length of 12 mm was not submitted, serving as control. So, the experimental design was composed by different ratios of post coronal length/post radicular length and mechanical cycling (MC): Gr1- 1/1 + MC; Gr2- 3/4 + MC; Gr3- 3/5 + MC; Gr4- 1/2 + MC. All groups were immersed in a 1% toluidine blue solution. After 24 hours, the teeth were longitudinally sectioned and the microleakage scores was given by a blind operator. Data were submitted to Kruskal-Wallis test (p = 0.05). The experimental variables were simulated in twodimensional finite element analysis (2D-FEA). The maximum principal stress distributions were compared. Results No difference was observed in microleakage values between the cycled groups, whilst the control groups showed the lowest values. FEA analysis showed similar maximum principal stress distribution between the groups. Conclusion Mechanical cycling affected the values of coronal microleakage and different cementation length generated similar values of coronal microleakage and stress distribution. Clinical significance These results showed that from the microleakage point of view, more conservative cementation lengths have the same effect as longer cementation lengths. How to cite this article Bergoli CD, de Carvalho RF, Balducci I, Meira JBC, de Araújo MAM, Valera MC. Influence of Fiber Post Cementation Length on Coronal Microleakage Values in vitro and Finite Element Analysis. J Contemp Dent Pract 2014; 15(4):444-450.


2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Xiaodong He ◽  
Christopher-Denny Matte ◽  
Tsz-Ho Kwok

AbstractThe paper presents a novel manufacturing approach to fabricate origami based on 3D printing utilizing digital light processing. Specifically, we propose to leave part of the model uncured during the printing step, and then cure it in the post-processing step to set the shape in a folded configuration. While the cured regions in the first step try to regain their unfolded shape, the regions cured in the second step attempt to keep their folded shape. As a result, the final shape is obtained when both regions’ stresses reach equilibrium. Finite element analysis is performed in ANSYS to obtain the stress distribution on common hinge designs, demonstrating that the square-hinge has a lower maximum principal stress than elliptical and triangle hinges. Based on the square-hinge and rectangular cavity, two variables—the hinge width and the cavity height—are selected as principal variables to construct an empirical model with the final folding angle. In the end, experimental verification shows that the developed method is valid and reliable to realize the proposed deformation and 3D development of 2D hinges.


2014 ◽  
Vol 633-634 ◽  
pp. 693-698
Author(s):  
Long Xin ◽  
Shi Chao Cui ◽  
Qi Lin Shu

In this paper, the ram of boring and milling machining center is taken as the research object. A new method that hydraulic pull rods compensation is proposed to solve the problem of deformation compensation of long stroke ram of boring and milling machining center. Firstly, the method of finite element analysis is used to get the laws of ram deformation and the relationship curve between the ram deformation and the stroke of ram. Secondly, the preliminary calculation value of pull rods compensation force is derived based on the theoretical analysis of material mechanics. The relationship curve between compensation force and the stroke of ram is obtained by finite element analysis and polynomial least squares method. Finally, the analyzed results are as follows: the laws of ram deformation distribution is accurately predicted by the used method, the deflection error of the ram is well controlled,and the machining precision is significantly improved.


Micromachines ◽  
2018 ◽  
Vol 9 (11) ◽  
pp. 578 ◽  
Author(s):  
Bingrui Lv ◽  
Guilian Wang ◽  
Bin Li ◽  
Haibo Zhou ◽  
Yahui Hu

This paper describes the innovative design of a three-dimensional (3D) motion device based on a flexible mechanism, which is used primarily to produce accurate and fast micro-displacement. For example, the rapid contact and separation of the tool and the workpiece are realized by the operation of the 3D motion device in the machining process. This paper mainly concerns the device performance. A theoretical model for the static performance of the device was established using the matrix-based compliance modeling (MCM) method, and the static characteristics of the device were numerically simulated by finite element analysis (FEA). The Lagrangian principle and the finite element analysis method for device dynamics are used for prediction to obtain the natural frequency of the device. Under no-load conditions, the dynamic response performance and linear motion performance of the three directions were tested and analyzed with different input signals, and three sets of vibration trajectories were obtained. Finally, the scratching experiment was carried out. The detection of the workpiece reveals a pronounced periodic texture on the surface, which verifies that the vibration device can generate an ideal 3D vibration trajectory.


2021 ◽  
pp. 1-14
Author(s):  
Xiaodong Chen ◽  
ZM Xie ◽  
Huifeng Tan

Abstract How to enlarge the output displacement is a key issue in the research field of microgrippers. It is difficult to further enlarge the output displacement for the traditional displacement transmission mechanism (DTM). In this research, a two-stage amplification cylinder-driven DTM based on the compliant mechanisms is designed to realize the displacement output expansion. The opening and closing of the clamping jaws is driven by the air cylinder to enlarge the output displacement of the microgripper. According to the analysis of statics model of the mechanism, the relationship between the output displacement of the microgripper and the driving pressure of the cylinder is established. The magnification of the microgripper is obtained using a dynamic model. Moreover, based on the finite element analysis, the mechanical structure parameters are optimized. The microgripper was fabricated by utilizing wire electro discharge machining (WEDM) technique, and then a series of experiments were carried out to obtain the relationship between the displacement and the driving pressure. It is found that the maximum output displacement measured is 1190.4μm under the pressure of 0-0.6 Mpa, corresponding to the magnification of 47.63. Compared with the results of finite element analysis and theoretical calculation, the test results have a discrepancy of 2.39% and 6.62%, respectively. The microgripper has successfully grasped a variety of micro-parts with irregular shapes, and parallel grasping can be achieved, demonstrating the potential application of this design in the field of micromanipulation.


Sign in / Sign up

Export Citation Format

Share Document