Performance Analysis of the Low-Temperature Solar-Boosted Power Generation System—Part I: Comparison Between Kalina Solar System and Rankine Solar System

2012 ◽  
Vol 135 (1) ◽  
Author(s):  
Faming Sun ◽  
Yasuyuki Ikegami ◽  
Hirofumi Arima ◽  
Weisheng Zhou

On the base of the two classical thermodynamic cycles (Kalina cycle and Rankine cycle), solar-boosted Kalina system (Kalina solar system) and solar-boosted Rankine system (Rankine solar system) with traditional nonconcentrating flat plate solar collector (FPSC) and evacuated tube solar collector (ETSC) are investigated in the present paper. The proposed solar systems are considered to be the hybrid of power generation subcycle and solar collector subcycle. Their electricity generating performances are compared under their respective optimal operating conditions to clarify which one is more competitive in solar utilization. Results show that ETSC is the better choice for the both solar systems. Further, the performance comparison shows that the low-temperature solar energy utilized in Kalina cycle is predominant to generate electricity. Meanwhile, the study also find that mass flow rate of the power generation subcycle, mass flow rate of the solar collector subcycle, mass fraction of ammonia and the regenerator performance are important operational parameters for high performance of the Kalina solar system. Finally, with the aid of the weather conditions of Kumejima Island in Japan, the perceptual knowledge for Kalina solar system by using an application case is shown in the paper.

2018 ◽  
Vol 141 (3) ◽  
Author(s):  
Oscar A. López-Núñez ◽  
J. Arturo Alfaro-Ayala ◽  
J. J. Ramírez-Minguela ◽  
J. Nicolás Flores-Balderas ◽  
J. M. Belman-Flores

A solar radiation model is applied to a low temperature water-in-glass evacuated tubes solar collector to predict its performance via computational fluid dynamics (CFD) numerical simulations. This approach allows obtaining the transmitted, reflected, and absorbed solar radiation flux and the solar heat flux on the surface of the evacuated tubes according to the geographical location, the date, and the hour of a day. Different environmental and operational conditions were used to obtain the outlet temperature of the solar collector; these results were validated against four experimental tests based on an Official Mexican Standard resulting in relative errors between 0.8% and 2.6%. Once the model is validated, two cases for the solar collector were studied: (i) different mass flow rates under a constant solar radiation and (ii) different solar radiation (due to the hour of the day) under a constant mass flow rate to predict its performance and efficiency. For the first case, it was found that the outlet temperature decreases as the mass flow rate increases reaching a steady value for a mass flow rate of 0.1 kg/s (6 l/min), while for the second case, the results showed a corresponding outlet temperature behavior to the solar radiation intensity reaching to a maximum temperature of 36.5 °C at 14:00 h. The CFD numerical study using a solar radiation model is more realistic than the previous reported works leading to overcome a gap in the knowledge of the low temperature evacuated tube solar collectors.


2021 ◽  
Vol 12 (3) ◽  
pp. 061-071
Author(s):  
Samer Yassin Alsadi ◽  
Tareq Foqha

Little works considered the optimization of working fluids in solar systems. Engineers, designers and scientists are interested with the optimization problems, furthermore it is very important specially, for solar systems to improve the energetic behavior and increase their efficiencies as a conversion system of solar irradiance to a useful thermal power. According to the available literature, the criteria of optimization mainly relates to energetic and economic analysis (one of them or both). The analysis was based upon the maximum useful energy obtained from solar collector. Accordingly, the optimum mass flow rate was found aspires to infinity. The second analysis is based upon minimum cost of the unit of useful energy [$/W]. The optimum mass flow rate of solar air-heating flat-plate collector for the considered domestic solar heating system has been found 29 kg/h per square meters of solar collectors. This paper deals with a third criteria that is, the amount of the additional energy required to achieve the required task from the solar system by means of auxiliary heating system. In where both the outlet temperature and mass flow rate play crucial role in the heat exchange between the fluid in the collector loop and the fluid in the load loop.


2005 ◽  
Vol 127 (5) ◽  
pp. 1029-1037 ◽  
Author(s):  
L. O. Schunk ◽  
G. F. Nellis ◽  
J. M. Pfotenhauer

Growing interest in larger scale pulse tubes has focused attention on optimizing their thermodynamic efficiency. For Stirling-type pulse tubes, the performance is governed by the phase difference between the pressure and mass flow, a characteristic that can be conveniently adjusted through the use of inertance tubes. In this paper we present a model in which the inertance tube is divided into a large number of increments; each increment is represented by a resistance, compliance, and inertance. This model can include local variations along the inertance tube and is capable of predicting pressure, mass flow rate, and the phase between these quantities at any location in the inertance tube as well as in the attached reservoir. The model is verified through careful comparison with those quantities that can be easily and reliably measured; these include the pressure variations along the length of the inertance tube and the mass flow rate into the reservoir. These experimental quantities are shown to be in good agreement with the model’s predictions over a wide range of operating conditions. Design charts are subsequently generated using the model and are presented for various operating conditions in order to facilitate the design of inertance tubes for pulse tube refrigerators. These design charts enable the pulse tube designer to select an inertance tube geometry that achieves a desired phase shift for a given level of acoustic power.


2018 ◽  
Vol 8 (9) ◽  
pp. 1413 ◽  
Author(s):  
Dan Yao ◽  
Kwongi Lee ◽  
Minho Ha ◽  
Cheolung Cheong ◽  
Inhiug Lee

A new pump, called the hybrid airlift-jet pump, is developed by reinforcing the advantages and minimizing the demerits of airlift and jet pumps. First, a basic design of the hybrid airlift-jet pump is schematically presented. Subsequently, its performance characteristics are numerically investigated by varying the operating conditions of the airlift and jet parts in the hybrid pump. The compressible unsteady Reynolds-averaged Navier-Stokes equations, combined with the homogeneous mixture model for multiphase flow, are used as the governing equations for the two-phase flow in the hybrid pump. The pressure-based methods combined with the Pressure-Implicit with Splitting of Operators (PISO) algorithm are used as the computational fluid dynamics techniques. The validity of the present numerical methods is confirmed by comparing the predicted mass flow rate with the measured ones. In total, 18 simulation cases that are designed to represent the various operating conditions of the hybrid pump are investigated: eight of these cases belong to the operating conditions of only the jet part with different air and water inlet boundary conditions, and the remaining ten cases belong to the operating conditions of both the airlift and jet parts with different air and water inlet boundary conditions. The mass flow rate and the efficiency are compared for each case. For further investigation into the detailed flow characteristics, the pressure and velocity distributions of the mixture in a primary pipe are compared. Furthermore, a periodic fluctuation of the water flow in the mass flow rate is found and analyzed. Our results show that the performance of the jet or airlift pump can be enhanced by combining the operating principles of two pumps into the hybrid airlift-jet pump, newly proposed in the present study.


2021 ◽  
Vol 39 (4) ◽  
pp. 1225-1235
Author(s):  
Ajay K. Gupta ◽  
Manoj Kumar ◽  
Ranjit K. Sahoo ◽  
Sunil K. Sarangi

Plate-fin heat exchangers provide a broad range of applications in many cryogenic industries for liquefaction and separation of gasses because of their excellent technical advantages such as high effectiveness, compact size, etc. Correlations are available for the design of a plate-fin heat exchanger, but experimental investigations are few at cryogenic temperature. In the present study, a cryogenic heat exchanger test setup has been designed and fabricated to investigate the performance of plate-fin heat exchanger at cryogenic temperature. Major parameters (Colburn factor, Friction factor, etc.) that affect the performance of plate-fin heat exchangers are provided concisely. The effect of mass flow rate and inlet temperature on the effectiveness and pressure drop of the heat exchanger are investigated. It is observed that with an increase in mass flow rate effectiveness and pressure drop increases. The present setup emphasis the systematic procedure to perform the experiment based on cryogenic operating conditions and represent its uncertainties level.


Author(s):  
Dominik Schlüter ◽  
Robert P. Grewe ◽  
Fabian Wartzek ◽  
Alexander Liefke ◽  
Jan Werner ◽  
...  

Abstract Rotating stall is a non-axisymmetric disturbance in axial compressors arising at operating conditions beyond the stability limit of a stage. Although well-known, its driving mechanisms determining the number of stall cells and their rotational speed are still marginally understood. Numerical studies applying full-wheel 3D unsteady RANS calculations require weeks per operating point. This paper quantifies the capability of a more feasible quasi-2D approach to reproduce 3D rotating stall and related sensitivities. The first part of the paper deals with the validation of a numerical baseline the simplified model is compared to in detail. Therefore, 3D computations of a state-of-the-art transonic compressor are conducted. At steady conditions the single-passage RANS CFD matches the experimental results within an error of 1% in total pressure ratio and mass flow rate. At stalled conditions, the full-wheel URANS computation shows the same spiketype disturbance as the experiment. However, the CFD underpredicts the stalling point by approximately 7% in mass flow rate. In deep stall, the computational model correctly forecasts a single-cell rotating stall. The stall cell differs by approximately 21% in rotational speed and 18% in circumferential size from the experimental findings. As the 3D model reflects the compressor behaviour sufficiently accurate, it is considered valid for physical investigations. In the second part of the paper, the validated baseline is reduced in radial direction to a quasi-2D domain only resembling the compressor tip area. Four model variations regarding span-wise location and extent are numerically investigated. As the most promising model matches the 3D flow conditions in the rotor tip region, it correctly yields a single-cell rotating stall. The cell differs by only 7% in circumferential size from the 3D results. Due to the impeded radial migration in the quasi-2D slice, however, the cell exhibits an increased axial extent. It is assumed, that the axial expansion into the adjacent rows causes the difference in cell speed by approximately 24%. Further validation of the reduced model against experimental findings reveals, that it correctly reflects the sensitivity of circumferential cell size to flow coefficient and individual cell speed to compressor shaft speed. As the approach reduced the wall clock time by 92%, it can be used to increase the physical understanding of rotating stall at much lower costs.


2018 ◽  
Vol 204 ◽  
pp. 06007
Author(s):  
Mohammad Mahardika

Every year, Indonesia's population increase so as energy demand. To fulfill Indonesia's energy needs, the capacity of energy production should be increased. Indonesia government has made a solution by propose 35.000 MW program to increase energy production and electrification ratio in Indonesia. An insulated area where electricity did not reach, has many problem to get electricity such as limited infrastructure, low fuel energy content, and expensive turbine. To solve these problem, multi-vane expander (MVE) can be used to extract the low energy and is cheap. MVE have many advantages such as cheap, easy to manufacture, able to operate with 2 phase, and able to low speed operation. But, the disadvantage of this type of expander is leakage. In this paper, experimental and CFD analysis of MVE are conducted. The experiment generated power of 25.7 watt with isentropic and volumetric efficiency of 11.6% and 11.7% by using operating condition of 1.5 bar, 115.6 °C, 626 rpm, and mass flow rate of 80 kg/h. The CFD model of the expander is created with the same dimension and operating conditions as experimental. The result for isentropic efficiency is inversely proportional with mass flow rate and for volumetric efficiency, power, and expander rotation are directly proportional with mass flow rate.