Characterization of Tensile and Compressive Behavior of Microscale Sheet Metals Using a Transparent Microwedge Device

Author(s):  
James Magargee ◽  
Jian Cao ◽  
Rui Zhou ◽  
Morgan McHugh ◽  
Damon Brink ◽  
...  

The cyclic and compressive mechanical behavior of ultrathin sheet metals was experimentally investigated. A novel transparent wedge device was designed and fabricated to prevent the buckling of thin sheets under compressive loads, while also allowing full field strain measurements of the specimen using digital imaging methods. Thin brass and stainless steel sheet metal specimens with thicknesses on the order of 10–100 μm were tested using the microwedge device. Experimental results show that the device can be used to delay the onset of early buckling modes of a thin sheet under compression, which is critical in examining the compressive and cyclic mechanical behavior of sheet metals.

Author(s):  
James Magargee ◽  
Jian Cao ◽  
Rui Zhou ◽  
Morgan McHugh ◽  
Damon Brink ◽  
...  

The cyclic and compressive mechanical behavior of ultra-thin sheet metals was experimentally investigated. A novel transparent wedge device was designed and fabricated to prevent the buckling of thin sheets under compressive loads, while also allowing full field strain measurements of the specimen using digital imaging methods. Thin brass and stainless steel sheet metal specimens were tested using the micro-wedge device. Experimental results show that the device can be used to delay the onset of early buckling modes of a thin sheet under compression, which is critical in examining the compressive and cyclic mechanical behavior of sheet metals.


2007 ◽  
Vol 44 (21) ◽  
pp. 6930-6944 ◽  
Author(s):  
Helena Jin ◽  
Wei-Yang Lu ◽  
Simon Scheffel ◽  
Terry D. Hinnerichs ◽  
Michael K. Neilsen

2011 ◽  
Vol 1333 ◽  
Author(s):  
Banafsheh Babakhani ◽  
Douglas G. Ivey

ABSTRACTManganese oxide electrodes are synthesized by anodic deposition on Au coated Si substrates from acetate-containing aqueous solutions. By changing the deposition parameters including deposition current density, electrolyte composition, pH and temperature, a series of nanocrystalline manganese oxide electrodes with various morphologies (non–uniform continuous coatings, rod–like structures, aggregated rods and thin sheets) is obtained. Detailed microstructural characterization of as-deposited electrodes is conducted using scanning electron microscopy (SEM).Electrochemical analysis using cyclic voltammetry showed that manganese oxide electrodes with rod–like and thin sheet morphology exhibit enhanced electrochemical performance by improving manganese oxide utilization. The highest specific capacitance (~230 F g−1) and capacitance retention rates (~88%) are obtained for manganese oxide thin sheets after 250 cycles in 0.5M Na2SO4 at 20 mV s−1.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 590
Author(s):  
Jennifer Cauzzo ◽  
Nikhil Jayakumar ◽  
Balpreet Singh Ahluwalia ◽  
Azeem Ahmad ◽  
Nataša Škalko-Basnet

The rapid development of nanomedicine and drug delivery systems calls for new and effective characterization techniques that can accurately characterize both the properties and the behavior of nanosystems. Standard methods such as dynamic light scattering (DLS) and fluorescent-based assays present challenges in terms of system’s instability, machine sensitivity, and loss of tracking ability, among others. In this study, we explore some of the downsides of batch-mode analyses and fluorescent labeling, while introducing quantitative phase microscopy (QPM) as a label-free complimentary characterization technique. Liposomes were used as a model nanocarrier for their therapeutic relevance and structural versatility. A successful immobilization of liposomes in a non-dried setup allowed for static imaging conditions in an off-axis phase microscope. Image reconstruction was then performed with a phase-shifting algorithm providing high spatial resolution. Our results show the potential of QPM to localize subdiffraction-limited liposomes, estimate their size, and track their integrity over time. Moreover, QPM full-field-of-view images enable the estimation of a single-particle-based size distribution, providing an alternative to the batch mode approach. QPM thus overcomes some of the drawbacks of the conventional methods, serving as a relevant complimentary technique in the characterization of nanosystems.


2013 ◽  
Vol 22 ◽  
pp. 85-93
Author(s):  
Shuang Yi Liu ◽  
Min Min Tang ◽  
Ai Kah Soh ◽  
Liang Hong

In-situ characterization of the mechanical behavior of geckos spatula has been carried out in detail using multi-mode AFM system. Combining successful application of a novel AFM mode, i.e. Harmonix microscopy, the more detail elastic properties of spatula is brought to light. The results obtained show the variation of the mechanical properties on the hierarchical level of a seta, even for the different locations, pad and stalk of the spatula. A model, which has been validated using the existing experimental data and phenomena as well as theoretical predictions for geckos adhesion, crawling and self-cleaning of spatulae, is proposed in this paper. Through contrast of adhesive and craw ability of the gecko on the surfaces with different surface roughness, and measurement of the surface adhesive behaviors of Teflon, the most effective adhesion of the gecko is more dependent on the intrinsic properties of the surface which is adhered.


2017 ◽  
Vol 35 (13) ◽  
pp. 2541-2547 ◽  
Author(s):  
Zhi Qiao ◽  
Yudong Yao ◽  
Xiaochao Wang ◽  
Wei Fan ◽  
Zunqi Lin
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document