Reduction of Fan and Compressor Wake Defect Using Plasma Actuation for Tonal Noise Reduction

2010 ◽  
Vol 133 (1) ◽  
Author(s):  
Sébastien Lemire ◽  
Huu Duc Vo

This paper proposes a new technique to reduce the noise generated by rotor-stator interaction (tonal noise) in fans and compressors. The method involves the use of single dielectric barrier discharge (plasma) actuators near the blade trailing edge to reduce blade wakes. Plasma actuators are a new and simple type of active flow control device consisting of two parallel and offset electrodes separated by a layer of dielectric material. The application of a high ac voltage at high frequency to the electrodes generates a body force on the flow in the vicinity of the electrodes to inject momentum without mass addition. A preliminary assessment of the proposed concept is performed with a computational study on modern low-speed compressor rotor geometry. A plasma actuator model is implemented in an established turbomachinery CFD code. Simulations are carried out to evaluate the effect of the actuator strength, location, and actuation method (continuous versus pulsed) on the rotor wake. Results show that plasma actuators operated in continuous mode near the trailing edge can significantly influence the wake of the rotor with relatively little power consumption. The effectiveness of the actuation is proportional to actuator strength (induced body force). The exact position of the actuator in the trailing edge region has little effect on the effectiveness of the actuation. The results from simulations with pulsed actuation show very low time-averaged influence on the wake and are not fully conclusive, due possibly to the frequencies simulated and the limitations of the RANS CFD tool.

Author(s):  
Se´bastien Lemire ◽  
Huu Duc Vo

This paper proposes a new technique to reduce the noise generated by rotor-stator interaction (tonal noise) in fans and compressors. The method involves the use of single dielectric barrier discharge (plasma) actuators near the blade trailing edge to reduce blade wakes. Plasma actuators are a new and simple type of active flow control device consisting of two parallel and offset electrodes separated by a layer of dielectric material. The application of a high AC voltage at high frequency to the electrodes generates a body force on the flow in the vicinity of the electrodes to inject momentum without mass addition. A preliminary assessment of the proposed concept is performed with a computational study on a modern low-speed compressor rotor geometry. A plasma actuator model is implemented in an established turbomachinery CFD code. Simulations are carried out to evaluate the effect of the actuator strength, location and actuation method (continuous versus pulsed) on the rotor wake. Results show that plasma actuators operated in continuous mode near the trailing edge can significantly influence the wake of the rotor with relatively little power consumption. The effectiveness of the actuation is proportional to actuator strength (induced body force). The exact position of the actuator in the trailing edge region has little effect on the effectiveness of the actuation. The results from simulations for pulsed actuation show very low time-averaged influence on the wake and are not fully conclusive, due possibly to the frequencies simulated and the limitations of the RANS CFD tool.


Author(s):  
F. F. Rodrigues ◽  
J. C. Pascoa ◽  
M. Trancossi

Dielectric Barrier Discharge plasma actuators are simple devices with great potential for active flow control applications. They have very interesting features which have made them a topic of interest for many researchers, for instance they present very low mass, fast response time, low cost, easy implementation and they are fully electronic with no moving parts. The dielectric material used in the construction of these devices present an important role in their performance. The variety of dielectrics studied in the literature is very restrict and the majority of the authors make use of Kapton, Teflon, Macor ceramic or PMMA. Furthermore, several authors reported difficulties in the durability of the dielectric layer when actuators operate at high levels of voltage and frequency. Considering this background, the present study focus on the experimental testing of alternative dielectric materials which can be used for DBD plasma actuators fabrication. Considering this, plasma actuators with dielectric layers made of Poly-Isobutylene rubber, Poly-Lactic acid and Acetoxy Silicon were experimentally tested. Although these dielectric materials are not commonly used in plasma actuators, their values of dielectric strength and dielectric permittivity indicate they can be good solutions. The plasma actuators facbricated with these alternative dielectric materials were experimentally analysed in terms of electrical characteristics and induced flow velocity, and the obtained results were compared with an actuator made of Kapton which is, currently, the most common dielectric material for plasma actuators. The effectiveness of the actuators was estimated and the advantages and disadvantages of the use of each dielectric material were discussed.


2009 ◽  
Vol 2009 ◽  
pp. 1-13 ◽  
Author(s):  
Sebastien Lemire ◽  
Huu Duc Vo ◽  
Michael W. Benner

This paper proposes the use of plasma actuator to suppress boundary layer separation on a compressor blade suction side to increase axial compressor performance. Plasma actuators are a new type of electrical flow control device that imparts momentum to the air when submitted to a high AC voltage at high frequency. The concept presented in this paper consists in the positioning of a plasma actuator near the separation point on a compressor rotor suction side to increase flow turning. In this computational study, three parameters have been studied to evaluate the effectiveness of plasma actuator: actuator strength, position and actuation method (steady versus unsteady). Results show that plasma actuator operated in steady mode can increase the pressure ratio, efficiency, and power imparted by the rotor to the air and that the pressure ratio, efficiency and rotor power increase almost linearly with actuator strength. On the other hand, the actuator's position has limited effect on the performance increase. Finally, the results from unsteady simulations show a limited performance increase but are not fully conclusive, due possibly to the chosen pulsing frequencies of the actuator and/or to limitations of the CFD code.


2007 ◽  
Author(s):  
Sonya T. Smith ◽  
Angela Scribben ◽  
Matthew Goettke

Author(s):  
GholamHossein Maleki ◽  
Ali Reza Davari ◽  
Mohammad Reza Soltani

An extensive experimental investigation was conducted to study the effects of Dielectric Barrier Discharge (DBD), on the flow field of an airfoil at low Reynolds number. The DBD was mounted near the leading edge of a section of a wind turbine blade. It is believed that DBD can postpone the separation point on the airfoil by injecting momentum to the flow. The effects of steady actuations on the velocity profiles in the wake region have been investigated. The tests were performed at α = 4 to 36 degrees i.e. from low to deep stall angles of attack regions. Both surface pressure distribution and wake profile show remarkable improvement at high angles of attack, beyond the static stall angle of the airfoil when the plasma actuation was implemented. The drag calculated from the wake momentum deficit has further shown the favorable role of the plasma actuators to control the flow over the airfoil at incidences beyond the static stall angle of attack of this airfoil. The results demonstrated that DBD has been able to postpone the stall onset significantly. It has been observed that the best performance for the plasma actuation for this airfoil is in the deep stall angles of attack range. However, below and near the static stall angles of attack, plasma augmentation was pointed out to have a negligible improvement in the aerodynamic behavior.


Author(s):  
R. V. Chima

In this work computational models were developed and used to investigate applications of vortex generators (VGs) to turbomachinery. The work was aimed at increasing the efficiency of compressor components designed for the NASA Ultra Efficient Engine Technology (UEET) program. Initial calculations were used to investigate the physical behavior of VGs. A parametric study of the effects of VG height was done using 3-D calculations of isolated VGs. A body force model was developed to simulate the effects of VGs without requiring complicated grids. The model was calibrated using 2-D calculations of the VG vanes and was validated using the 3-D results. Then three applications of VGs to a compressor rotor and stator were investigated: 1. The results of the 3-D calculations were used to simulate the use of small casing VGs used to generate rotor preswirl or counterswirl. Computed performance maps were used to evaluate the effects of VGs. 2. The body force model was used to simulate large partspan splitters on the casing ahead of the stator. Computed loss buckets showed the effects of the VGs. 3. The body force model was also used to investigate the use of tiny VGs on the stator suction surface for controlling secondary flows. Near-surface particle traces and exit loss profiles were used to evaluate the effects of the VGs.


2005 ◽  
Vol 29 (2) ◽  
pp. 89-113 ◽  
Author(s):  
Niels Troldborg

A comprehensive computational study, in both steady and unsteady flow conditions, has been carried out to investigate the aerodynamic characteristics of the Risø-B1-18 airfoil equipped with variable trailing edge geometry as produced by a hinged flap. The function of such flaps should be to decrease fatigue-inducing oscillations on the blades. The computations were conducted using a 2D incompressible RANS solver with a k-w turbulence model under the assumption of a fully developed turbulent flow. The investigations were conducted at a Reynolds number of Re = 1.6 · 106. Calculations conducted on the baseline airfoil showed excellent agreement with measurements on the same airfoil with the same specified conditions. Furthermore, a more widespread comparison with an advanced potential theory code is presented. The influence of various key parameters, such as flap shape, flap size and oscillating frequencies, was investigated so that an optimum design can be suggested for application with wind turbine blades. It is concluded that a moderately curved flap with flap chord to airfoil curve ratio between 0.05 and 0.10 would be an optimum choice.


2021 ◽  
Author(s):  
F. F. Rodrigues ◽  
J. Nunes-Pereira ◽  
M. Abdollahzadeh ◽  
J. Pascoa ◽  
S. Lanceros-Mendez

Abstract Dielectric Barrier Discharge (DBD) plasma actuators are simple devices with great potential for active flow control applications. Further, it has been recently proven their ability for applications in the area of heat transfer, such as film cooling of turbine blades or ice removal. The dielectric material used in the fabrication of these devices is essential in determining the device performance. However, the variety of dielectric materials studied in the literature is very limited and the majority of the authors only use Kapton, Teflon, Macor ceramic or poly(methyl methacrylate) (PMMA). Furthermore, several authors reported difficulties in the durability of the dielectric layer when the actuators operate at high voltage and frequency. Also, it has been reported that, after long operation time, the dielectric layer suffers degradation due to its exposure to plasma discharge, degradation that may lead to the failure of the device. Considering the need of durable and robust actuators, as well as the need of higher flow control efficiencies, it is highly important to develop new dielectric materials which may be used for plasma actuator fabrication. In this context, the present study reports on the experimental testing of dielectric materials which can be used for DBD plasma actuators fabrication. Plasma actuators fabricated of poly(vinylidene fluoride) (PVDF) and polystyrene (PS) have been fabricated and evaluated. Although these dielectric materials are not commonly used as dielectric layer of plasma actuators, their interesting electrical and dielectric properties and the possibility of being used as sensors, indicate their suitability as potential alternatives to the standard used materials. The plasma actuators produced with these nonstandard dielectric materials were analyzed in terms of electrical characteristics, generated flow velocity and mechanical efficiency, and the obtained results were compared with a standard actuator made of Kapton. An innovative calorimetric method was implemented in order to estimate the thermal power transferred by these devices to an adjacent flow. These results allowed to discuss the ability of these new dielectric materials not only for flow control applications but also for heat transfer applications.


Author(s):  
Alessandro Armellini ◽  
Filippo Coletti ◽  
Tony Arts ◽  
Christophe Scholtes

The present contribution addresses the aero-thermal experimental and computational study of a trapezoidal cross-section model simulating a trailing edge cooling cavity with one rib-roughened wall. The flow is fed through tilted slots on one side wall and exits through straight slots on the opposite side wall. The flow field aerodynamics is investigated in part I of the paper. The reference Reynolds number is defined at the entrance of the test section and set at 67500 for all the experiments. A qualitative flow model is deduced from surface-streamline flow visualizations. Two-dimensional Particle Image Velocimetry measurements are performed in several planes around mid-span of the channel and recombined to visualize and quantify three-dimensional flow features. The jets issued from the tilted slots are characterized and the jet-rib interaction is analyzed. Attention is drawn to the motion of the flow deflected by the rib-roughened wall and impinging on the opposite smooth wall. The experimental results are compared with the numerical predictions obtained from the finite volume, RANS solver CEDRE.


Author(s):  
Mathias Deckers ◽  
John D. Denton

A theoretical and computational study into the aerodynamics of trailing-edge-cooled transonic turbine blades is described in this part of the paper. The theoretical study shows that, for unstaggered blades with coolant ejection, the base pressure and overall loss can be determined exactly by a simple control volume analysis. This theory suggests that a thick, cooled trailing edge with a wide slot can be more efficient than a thin, solid trailing edge. An existing time-marching finite volume method is adapted to calculate the transonic flow with trailing edge coolant ejection on a structured, quasi-orthogonal mesh. Good overall agreement between the present method, inviscid and viscous, and experimental evidence is obtained.