Pool Boiling Heat Transfer of Water on Finned Surfaces at Near Vacuum Pressures

2009 ◽  
Vol 132 (3) ◽  
Author(s):  
Mark Aaron Chan ◽  
Christopher R. Yap ◽  
Kim Choon Ng

This research paper presents a study of boiling heat transfer from longitudinal rectangular-finned surfaces immersed in saturated water at low vapor pressures. Finned surfaces with assorted fin spacing, fin thicknesses, and fin heights on a copper based surface have been investigated. All the finned surfaces were found to increase both boiling heat transfer coefficients and critical heat fluxes. An optimal fin thickness was found for a configuration, and heat transfer coefficients have been obtained at the pressures. Factors affecting the boiling characteristics have been identified and the optimal enhancement requires a balance of the active nucleation sites, bubble flow resistance, natural convection, thin film evaporation, liquid superheating, heat transfer area, bubble coalescence, and liquid reflux resistance. High speed visualization of vapor plug and vapor film generation on the boiling surfaces has revealed significant insights into the boiling mechanisms at low saturation pressures.

Author(s):  
Todd M. Bandhauer ◽  
Taylor A. Bevis

The principle limit for achieving higher brightness of laser diode arrays is thermal management. State of the art laser diodes generate heat at fluxes in excess of 1 kW cm−2 on a plane parallel to the light emitting edge. As the laser diode bars are packed closer together, it becomes increasingly difficult to remove large amounts of heat in the diminishing space between neighboring diode bars. Thermal management of these diode arrays using conduction and natural convection is practically impossible, and, therefore, some form of forced convective cooling must be utilized. Cooling large arrays of laser diodes using single-phase convection heat transfer has been investigated for more than two decades by multiple investigators. Unfortunately, either large fluid temperature increases or very high flow velocities must be utilized to reject heat to a single phase fluid, and the practical threshold for single phase convective cooling of laser diodes appears to have been reached. In contrast, liquid-vapor phase change heat transport can occur with a negligible increase in temperature and, due to a high enthalpy of vaporization, at comparatively low mass flow rates. However, there have been no prior investigations at the conditions required for high brightness edge emitting laser diode arrays: >1 kW cm−2 and >10 kW cm−3. In the current investigation, flow boiling heat transfer at heat fluxes up to 1.1 kW cm−2 was studied in a microchannel heat sink with plurality of very small channels (45 × 200 microns) using R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio in the vicinity of the laser diode. To characterize the heat transfer performance, a test facility was constructed that enabled testing over a range of fluid saturation temperatures (15°C to 25°C). Due to the very small geometric features, significant heat spreading was observed, necessitating numerical methods to determine the average heat transfer coefficient from test data. This technique is crucial to accurately calculate the heat transfer coefficients for the current investigation, and it is shown that the analytical approach used by many previous investigations requires assumptions that are inadequate for the very small dimensions and heat fluxes observed in the present study. During the tests, the calculated outlet vapor quality exceeded 0.6 and the base heat flux reached a maximum of 1.1 kW cm−2. The resulting experimental heat transfer coefficients are found to be as large a 58.1 kW m−2 K−1 with an average uncertainty of ±11.1%, which includes uncertainty from all measured and calculated values, required assumptions, and geometric discretization error from meshing.


Author(s):  
Koichi Hata ◽  
Suguru Masuzaki

The subcooled boiling heat transfer (HT) and the steady-state critical heat fluxes (CHFs) in a short SUS304-tube with twisted-tape insert are systematically measured for mass velocities (G = 4016 to 13850 kg/m2s), inlet liquid temperatures (Tin = 285.82 to 363.96 K), outlet pressures (Pout = 764.76 to 889.02 kPa) and exponentially increasing heat input (Q = Q0exp(t/τ), τ = 8.5 s) by the experimental water loop comprised of a multistage canned-type circulation pump controlled by an inverter. The SUS304 test tube of inner diameter (d = 6 mm), heated length (L = 59.5 mm), effective length (Leff = 49.1 mm), L/d (= 9.92), Leff/d (= 8.18) and wall thickness (δ = 0.5 mm) with average surface roughness (Ra = 3.18 μm) is used in this work. The SUS304 twisted tape with twist ratio, y [= H/d = (pitch of 180° rotation)/d], of 3.39 is used. The relation between inner surface temperature and heat flux for the SUS304-tube with the twisted-tape insert are clarified from non-boiling to CHF. The subcooled boiling heat transfer for SUS304-tube with the twisted-tape insert is compared with our empty SUS304-tube data and the values calculated by our and other workers’ correlations for the subcooled boiling heat transfer. The influences of the twisted-tape insert and the swirl velocity on the subcooled boiling heat transfer and the CHFs are investigated into details and the widely and precisely predictable correlations of the subcooled boiling heat transfer and the CHFs for turbulent flow of water in the SUS304-tube with twisted-tape insert are given based on the experimental data. The correlations can describe the subcooled boiling heat transfer coefficients and the CHFs obtained in this work within −25 to +15% difference.


Author(s):  
Gilberto Moreno ◽  
Sreekant Narumanchi ◽  
Charles King

This fundamental study characterizes the pool boiling performance of a new refrigerant, HFO-1234yf (hydrofluoroolefin 2,3,3,3-tetrafluoropropene). The similarities in thermophysical properties with HFC-134a and low global warming potential make HFO-1234yf the prospective next generation refrigerant in automotive air-conditioning systems. This study examines the possibility of using this refrigerant for two-phase cooling of hybrid and electric vehicle power electronic components. Pool boiling experiments were conducted with HFO-1234yf and HFC-134a at system pressures ranging from 0.7 to 1.7 MPa using horizontally oriented 1 cm2 heat sources. Results show that the boiling heat transfer coefficients of HFO-1234yf and HFC-134a are nearly identical at lower heat fluxes. HFO-1234yf yielded lower heat transfer coefficients at higher heat fluxes and lower critical heat flux (CHF) as compared with HFC-134a. To enhance boiling heat transfer, a copper microporous coating was applied to the test surfaces. The coating provided enhancement to both the boiling heat transfer coefficients and CHF, for both refrigerants, at all tested pressures. Increasing pressure decreases the level of heat transfer coefficient enhancements while increasing the level of CHF enhancements.


Author(s):  
Benjamin J. Jones ◽  
Suresh V. Garimella

The influence of surface roughness on flow boiling heat transfer and pressure drop in microchannels is experimentally explored. The microchannel heat sink employed in the study consists of ten parallel, 25.4 mm long channels with nominal dimensions of 500×500 μm2. The channels were produced by saw-cutting. Two of the test piece surfaces were roughened to varying degrees with electrical discharge machining (EDM). The roughness average Ra varied from 1.4 μm for the as-fabricated, saw-cut surface to 3.9 μm and 6.7 μm for the two roughened EDM surfaces. Deionized water was used as the working fluid. The experiments indicate that the surface roughness has little influence on boiling incipience and only a minor impact on saturated boiling heat transfer coefficients at lower heat fluxes. For wall heat fluxes above 1500 kW/m2, the two EDM surfaces (3.9 μm and 6.7 μm) have similar heat transfer coefficients that were 20–35% higher than those measured for the saw-cut surface (1.4 μm). A modified Bertsch et al. [2009, “A Composite Heat Transfer Correlation for Saturated Flow Boiling in Small Channels,” Int. J. Heat Mass Transfer, 52, pp. 2110–2118] correlation was found to provide acceptable predictions of the flow boiling heat transfer coefficient over the range of conditions tested. Analysis of the pressure drop measurements indicates that only the roughest surface (6.7 μm) has an adverse effect on the two-phase pressure drop.


Author(s):  
K-J Park ◽  
D Jung ◽  
S E Shim

In this work, nucleate pool boiling heat transfer coefficients (HTCs) of five refrigerants of differing vapour pressures are measured on a horizontal, smooth copper surface of 9.53×9.53 mm. The tested refrigerants are R123, R152a, R134a, R22, and R32 and HTCs are taken from 10 kW/m2 to the critical heat flux (CHF) of each refrigerant. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and in the liquid pool, respectively. Test results show that nucleate pool boiling HTCs of halogenated refrigerants increase as the heat flux and vapour pressure increase. This typical trend is maintained even at high heat fluxes above 200 kW/m2. Zuber's prediction equation for CHF is quite accurate showing a maximum deviation of 21 per cent for all refrigerants tested. For all refrigerants, Stephan and Abdelsalam's well-known correlation underpredicted nucleate boiling HTC data up to the CHF with an average deviation of 21.3 per cent, while Cooper's correlation overpredicted the data with an average deviation of 14.2 per cent. On the other hand, Gorenflo's and Jung et al.'s correlations showed 5.8 and 6.4 per cent deviations, respectively, in the entire nucleate boiling range up to the CHF.


Author(s):  
Rong Xiao ◽  
Shalabh C. Maroo ◽  
Evelyn N. Wang

Recent advancements in integrated circuits demand the development of novel thermal management schemes that can dissipate ultra-high heat fluxes with high heat transfer coefficients. Previous study demonstrated the potential of thin film evaporation on micro/nanostructured surfaces [1–11]. Theoretical calculations indicate that heat transfer coefficients on the order of 106 W/m2K and heat fluxes of 105 W/cm2 can be achievable with water [1, 5–6]. However, in previous experimental setup, the coolant has to propagate across the surface which limits the increase in heat flux and the heat transfer coefficient, while adding complexity to the system design. This work aims to decouple the propagation of the coolant from the evaporation process through a novel experimental configuration. Thin nanoporous membranes of 13 mm diameter were used where a metal layer was deposited on the top surface to serve as a resistance heater. Liquid was supplied from the bottom of the membrane, driven through the nanopores by capillary force, and evaporated from the top surface. Heat transfer coefficient over 104 W/m2K was obtained with isopropyl alcohol (IPA) as the coolant, which is only two orders of magnitude smaller than the theoretical limit. This work offers insights into optimal experimental designs towards achieving kinetic limits of heat transfer for thin film evaporation based thermal management solutions.


Author(s):  
Lihong Wang ◽  
Min Chen ◽  
Manfred Groll

Flow boiling heat transfer characteristics of R134a were experimentally investigated in a horizontal stainless steel mini-tube. The inner diameter of the test tube is 1.3 mm and the tube wall thickness is 0.1 mm. Local heat transfer coefficients are obtained over a range of vapor qualities up to 0.8, mass fluxes from 310 to 860 kg/m2s, heat fluxes from 21 to 50 kW/m2, and saturation pressures from 6.5 to 7.5 bar. The mass flux, heat flux, saturation pressure, and vapor quality dependences of heat transfer coefficients are demonstrated. Based on an available model in recent literature potential heat transfer mechanisms are also analyzed.


Author(s):  
Benjamin J. Jones ◽  
Suresh V. Garimella

The influence of surface roughness on flow boiling heat transfer and pressure drop in microchannels is experimentally explored. The microchannel heat sink employed in the study consists of 10 parallel, 25.4 mm long channels with nominal dimensions of 500 μm × 500 μm. The channels were produced by saw-cutting. Two of the test piece surfaces were roughened to varying degrees with electrical discharge machining (EDM). The roughness average, Ra, varied from 1.4 μm for the as-fabricated, saw-cut surface to 3.9 and 6.7 μm for the two roughened EDM surfaces. Deionized water was used as the working fluid. Experiments indicate that the surface roughness has little influence on boiling incipience and only a minor impact on saturated boiling heat transfer coefficients at lower heat fluxes. For wall heat fluxes above 1500 kW/m2, the two EDM surfaces (3.9 and 6.7 μm) have similar heat transfer coefficients that were 20 to 35% higher than those measured for the saw cut surface (1.4 μm). Analysis of the pressure drop measurements indicates that only the roughest surface (6.7 μm) has an adverse effect on the two-phase pressure drop.


1988 ◽  
Vol 110 (4a) ◽  
pp. 976-981 ◽  
Author(s):  
M. K. Jensen ◽  
J.-T. Hsu

Boiling heat transfer outside of a section of a uniformly heated horizontal tube bundle in an upward crossflow was investigated using R-113 as the working fluid. The inline tube bundle had five columns and 27 rows with a pitch-to-diameter ratio of 1.3. Heat transfer coefficients obtained from the 14 instrumented tubes are reported for a range of fluid and flow conditions; slightly subcooled liquid inlet conditions were used. At most heat fluxes there was no significant variation in the local heat transfer coefficients throughout the tube bundle. However, at low heat fluxes and mass velocities, the heat transfer coefficient increased at positions higher in the tube bundle. As pressure and mass velocity increased so did the heat transfer coefficients. For the local heat transfer coefficient, a Chen-type correlation is compared to the data; the data tend to be overpredicted by about 20 percent. Reasons for the overprediction are suggested.