Development of Titanium Needle Probes for Neural Recording and Evaluation of Magnetic Resonance Imaging Artifacts

Author(s):  
Hargsoon Yoon ◽  
Devesh C. Deshpande ◽  
T. H. Kim ◽  
Eun-Kee Jeong ◽  
Robert E. Harbaugh ◽  
...  

The aim of this research is to develop a mechanically flexible and strong neural probe with microelectrode array for future clinical applications in neural prosthetics and neurological disorder fields. This research specifically focuses on the development of neural recording electrodes with iridium oxide (IrOx) electrodes on a titanium needle probe and discusses the fabrication techniques and their evaluation for physical properties and electrochemical performance. Microfabrication processes, such as inductive coupled plasma etching, were used to deeply etch the Ti needle structures on titanium foils, and microelectrode arrays with iridium oxide films were formed by electrochemical deposition for low impedance neural recording. Mechanical and electrochemical analyses were performed to verify the viability of Ti needle probes in vitro. The final section of this paper addresses the issue of magnetic resonance imaging artifacts of titanium needle probes, and test results are compared with similarly fabricated Si needle probes. The advantages of using a titanium needle probe are discussed in the application of neural probe electrodes, as well.

1991 ◽  
Vol 65 (05) ◽  
pp. 549-552 ◽  
Author(s):  
A Blinc ◽  
G Planinšič ◽  
D Keber ◽  
O Jarh ◽  
G Lahajnar ◽  
...  

SummaryMagnetic resonance imaging was employed to study the dependence of clot lysing patterns on two different modes of transport of urokinase into whole blood clots. In one group of clots (nonperfused clots, n1 = 10), access of urokinase to the fibrin network was possible by diffusion only, whereas in the other group (perfused clots, n2 = 10) bulk flow of plasma containing urokinase was instituted through occlusive clots by a pressure difference of 3 .7 kPa (37 cm H2O) across 3 cm long clots with a diameter of 4 mm. It was determined separately that this pressure difference resulted in a volume flow rate of 5.05 ± 2.4 × 10−2 ml/min through occlusive clots. Perfused clots diminished in size significantly in comparison to nonperfused ones already after 20 min (p <0.005). Linear regression analysis of two-dimensional clot sizes measured by MRI showed that the rate of lysis was more than 50-times faster in the perfused group in comparison to the nonperfused group. It was concluded that penetration of the thrombolytic agent into clots by perfusion is much more effective than by diffusion. Our results might have some implications for understanding the differences in lysis of arterial and venous thrombi.


2016 ◽  
Vol 13 (7) ◽  
pp. 697-705 ◽  
Author(s):  
Chen Zhu ◽  
Xiao Enhua ◽  
Shang Quanliang ◽  
Kang Zhen ◽  
Tan Huilong ◽  
...  

2021 ◽  
Vol 315 ◽  
pp. 110900
Author(s):  
Jiaqi Hu ◽  
Yi Chen ◽  
Hui Zhang ◽  
Zhenxia Chen ◽  
Yun Ling ◽  
...  

1986 ◽  
Vol 21 (9) ◽  
pp. S5
Author(s):  
John Drace ◽  
Stuart Young ◽  
Dieter Enzmann

Sign in / Sign up

Export Citation Format

Share Document