Transient Heat Transfer in a Vapor-Heated Heat Exchanger With Arbitrary Timewise-Variant Flow Perturbation

1964 ◽  
Vol 86 (2) ◽  
pp. 133-142 ◽  
Author(s):  
Wen-Jei Yang

An analysis is made of transient heat transfer in a vapor-heated heat exchanger with an arbitrary timewise-variant flow perturbation. The heat-transfer coefficient between the tube and coolant is assumed to vary like the n power of the coolant velocity. Results are obtained through the use of the perturbation technique. General relations are presented in closed form and their application is illustrated by carrying out some typical examples: step, linear, exponential, and sinusoidal transients in the coolant flow velocity. The influence of the system parameters on the variation of the coolant temperature is investigated. A phenomenon of resonance in the amplitude-ratio and phase-shift is disclosed for the oscillating flow transient. This phenomenon is explained by analyzing the enthalpy change of the coolant particle in the heat exchanger. The results are also compared with the analyses that have assumed a constant heat-transfer coefficient. Heat exchangers to which these results apply include the double-pipe and shell- and-tube type heat exchangers.

2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


2013 ◽  
Vol 655-657 ◽  
pp. 461-464 ◽  
Author(s):  
Su Fang Song

The three-dimensional model of heat exchangers with continuous helical baffles was built. The fluid flow dynamics and heat transfer of shell side in the helical baffled heat exchanger were simulated and calculated. The velocity, pressure and temperature distributions were achieved. The simulation shows that with the same baffle pitch, shell-side heat transfer coefficient increased by 25% and the pressure drop decreases by 18% in helical baffled heat exchanger compared with segmental helical baffles. With the analyzing of the flow and heat transfer in heat exchanger in 5 different inclination angles from 11°to 21°, it can be found that both shell side heat transfer coefficient and pressure drop will reduce respectively by 86% and 52% with the increases 11°to 21°of the inclination angles. Numerical simulation provided reliable theoretical reference for further engineering research of heat exchanger with helical baffles.


2017 ◽  
Vol 9 (4) ◽  
pp. 451-461
Author(s):  
Artur Rubcov ◽  
Sabina Paulauskaitė ◽  
Violeta Misevičiūtė

The paper provides the results of experimental and theoretical test of a wavy fin and tube heat exchanger used to cool air in a ventilation system when the wavy fin of the heat exchanger is dry and wet. The experimental tests, performed in the range of 1000<Re<4500 of the Reynolds number applying LMTD-LMED methodology, determined the dependency of the heat transfer coefficient on the supplied air flow rate with the varying geometry of the heat exchanger (the number of tube rows, the distance between fins, the thickness of the fin and the diameter of the tube). The experimental tests were performed on 9 heat exchangers in heating and 6 heat exchangers in cooling mode. After processing the results of the experimental tests, empirical equation defining the characteristics of the heat transfer coefficient of all heat exchangers were derived. The maximum heat transfer coefficient deviation is 11.6 percent. The correction factor of the wet fin (Lewis number) depending on the number of Reynolds, which ranges from 0.75 to 1.1 also is determined. Maximum capacity deviation equals 3.7 percent. The obtained equations can only be applied to a certain group of heat exchangers (with the same shape of fins or the distance between the tubes). The results of the experimental test and simulation with ANSYS program are compared and the heat transfer coefficients vary from 6.5 to 11.4 percent.


2019 ◽  
Vol 70 (6) ◽  
pp. 2040-2043
Author(s):  
Sinziana Radulescu ◽  
Loredana Irena Negoita ◽  
Ion Onutu

A relation for calculation of the effective overall heat transfer coefficient in a triple concentric-tube heat exchanger is proposed. The relation of the effective overall heat transfer coefficient is obtained based on total thermal resistance and it is applied within a case study for thermal analysis of two triple concentric-tube heat exchangers with different geometries, hot fluids and operating conditions. Through case study it is found that the values of effective overall heat transfer coefficient can be obtained with acceptable errors, up to 3 % for both heat exchangers.


1987 ◽  
Vol 109 (2) ◽  
pp. 287-294 ◽  
Author(s):  
S. M. Zubair ◽  
P. V. Kadaba ◽  
R. B. Evans

This paper presents a closed-form analytical method for the second-law-based thermoeconomic optimization of two-phase heat exchangers used as condensers or evaporators. The concept of “internal economy” as a means of estimating the economic value of entropy generated (due to finite temperature difference heat transfer and pressure drops) has been proposed, thus permitting the engineer to trade the cost of entropy generation in the heat exchanger against its capital expenditure. Results are presented in terms of the optimum heat exchanger area as a function of the exit/inlet temperature ratio of the coolant, unit cost of energy dissipated, and the optimum overall heat transfer coefficient. The total heat transfer resistance represented by (1/U = C1 + C2 Re−n) in the present analysis is patterned after Wilson (1915) which accommodates the complexities associated with the determination of the two-phase heat transfer coefficient and the buildup of surface scaling resistances. The analysis of a water-cooled condenser and an air-cooled evaporator is presented with supporting numerical examples which are based on the thermoeconomic optimization procedure of this paper.


Author(s):  
Yaping Chen ◽  
Ruibing Cao ◽  
Jiafeng Wu ◽  
Cong Dong ◽  
Yanjun Sheng

A set of experiments were conducted on the circumferential overlap trisection helical baffle heat exchangers with inclined angles of 20°, 24°, 28° and 32° single-thread and inclined angle of 32° dual-thread one, and a segmental baffle heat exchanger as a contrast scheme. The cylinder case of the testing heat exchanger is a common shell, while the tube bundle core could be replaced. The shell side heat transfer coefficient ho is obtained by subtract tube-side convection thermal resistance and tube wall conduction resistance from the overall heat transfer coefficient K. The curves of shell side heat transfer coefficient ho, pressure drop Δpo, Nusselt number Nuo, and axial Euler number Euz,o are presented versus axial Reynolds number Rez,o. A comprehensive performance index Nuo/Euz,o is suggested to demonstrate the integral properties of both heat transfer and flow resistance of different schemes, and the curves of Nuo/Euz,o versus Rez,o of the different schemes are presented. The results show that the scheme with inclined angle 20° performs better than other schemes, and the scheme with inclined angle 24° ranks the second, however the segment scheme ranks the last. The curves of Nuo/Euz,o of both schemes with inclined angle 32° of single-thread and dual-thread are almost coincident, even though their heat transfer coefficient and pressure drop curves are quite different. The results indicate also that for the circumferential overlap trisection helical baffle schemes the optimal inclined angle is around 20° instead of around 40° as rated by many literatures for the quadrant helical baffle schemes.


Author(s):  
Djamalutdin Chalaev ◽  
◽  
Nina Silnyagina ◽  

The use of advanced heat transfer surfaces (corrugated tubes of various modifications) is an effective way to intensify the heat transfer and improve the hydraulic characteristics of tubular heat exchangers. The methods for evaluating the use of such surfaces as working elements in tubular heat exchangers have not been developed so far. The thermal and hydrodynamic processes occurring in the tubes with the developed surfaces were studied to evaluate the efficiency of heat exchange therein. Thin-walled corrugated flexible stainless steel tubes of various modifications were used in experimental studies. The researches were carried out on a laboratory stand, which was designed as a heat exchanger type "tube in tube" with a corrugated inner tube. The stand was equipped with sensors to measure the thermal hydraulic flow conditions. The comparative analysis of operation modes of the heat exchanger with a corrugated inner tube of various modifications and the heat exchanger with a smooth inner tube was performed according to the obtained data. Materials and methods. A convective component of the heat transfer coefficient of corrugated tube increased significantly at identical flow conditions comparing with a smooth tube. Increasing the heat transfer coefficient was in the range of 2.0 to 2.6, and increased with increasing Reynolds number. The increase in heat transfer of specified range outstripped the gain of hydraulic resistance caused by increase of the flow. Results and discussion. CFD model in the software ANSYS CFX 14.5 was adapted to estimate the effect of the tube geometry on the intensity of the heat transfer process. A two-dimensional axially symmetric computer model was used for the calculation. The model is based on Reynolds equation (Navier-Stokes equations for turbulent flow), the continuity equation and the energy equation supplemented by the conditions of uniqueness. SST-turbulence model was used for the solution of the equations. The problem was solved in the conjugate formulation, which allowed assessing the efficiency of heat exchange, depending on various parameters (coolant temperature, coolant velocity, pressure). The criteria dependences were obtained Nu = f (Re, Pr). Conclusions. The use a corrugated tube as a working element in tubular heat exchangers can improve the heat transfer coefficient of 2.0 - 2.6 times, with an increase in hydraulic resistance in the heat exchanger of 2 times (compared with the use of smooth tubes). The criteria dependences obtained on the basis of experimental studies and mathematical modeling allow developing a methodology for engineering calculations for the design of new efficient heat exchangers with corrugated tubes.


Author(s):  
Dahai Guo ◽  
Danesh K. Tafti

The effect of inlet flow angles on flat tube multilouvered fin heat exchangers is studied. Five inlet flow angles, α= ±25, ±45 and 0 degrees are employed with respect to the face of the heat exchanger. One louver angle θ = 25 degrees, and three fin pitches, Fp = 1.0, 1.5 and 2.0 are considered. There is a strong correlation between the response of the flow efficiency and heat transfer coefficient to inlet flow angle. Positive flow angles, which are in the same direction as the louver angle, have to undergo a smaller rotation to be aligned with louver directed flow in the bank, and exhibit better performance characteristics than negative inlet flow angles. The first-order effect of inlet flow angles is to reduce the effective mass flow rate and Reynolds number through the heat exchanger. For positive flow angles and small fin pitches, the heat transfer coefficient correlates well with the effective Reynolds number {Reeff = Re(cosα)}. However, this is not the case when flow angles are negative and the fin pitch increases. Under these conditions, the Nusselt number deviates considerably from the effective Reynolds number analogy, with a subsequent loss in heat transfer capability. For large negative inlet flow angles (α = −45), the heat transfer coefficient drops as much as 50% for a fin pitch Fp = 2.


1997 ◽  
Vol 119 (3) ◽  
pp. 560-567 ◽  
Author(s):  
N.-H. Kim ◽  
J.-H. Yun ◽  
R. L. Webb

This paper deals with heat exchangers having plate fins of herringbone wave configuration. Correlations are developed to predict the air-side heat transfer coefficient and friction factor as a function of flow conditions and geometric variables of the heat exchanger. Correlations are provided for both staggered and in-line arrays of circular tubes. A multiple regression technique was used to correlate 41 wavy fin geometries by Beecher and Fagan (1987), Wang et al. (1995), and Beecher (1968). For the staggered layout, 92 percent of the heat transfer data are correlated within ±10 percent and 91 percent of the friction data are correlated within ±15 percent.


2017 ◽  
Vol 16 (05n06) ◽  
pp. 1750020 ◽  
Author(s):  
S. Nallusamy ◽  
N. Manikanda Prabu

Heat exchanger plays an essential part in industrial sector in transferring the heat energy. Heat is exchanged between fluids in convection and conduction mode through the walls of the heat exchanger. If the heat transfer medium has low thermal conductivity, it will greatly limit the efficiency of the heat exchanger. Whenever the system acts subjected to an increase in the heat load, heat fluxes caused by more power and smaller size, cooling is one of the technical challenges faced by the industries. The objective of this research work is to evaluate the overall heat transfer coefficient through an experimental analysis on the convective heat transfer and flow characteristics of a nanofluid. In our experiment, the nanofluid consists of water and one percentage volume concentration of Al2O3-water nanofluid flowing through parallel and counter flow in shell and tube heat exchangers. About 50[Formula: see text]nm diameter of Al2O3 nanoparticles was used in this analysis and found that the overall heat transfer coefficient and convective heat transfer coefficient of nanofluid were slightly higher than those of the base liquid at same mass flow rate and inlet temperature. Here, there are three samples of dissimilar mass flow rates, which have been identified for conducting the experiments and their results are continuously monitored and reported. Finally, the observed results through an experimental investigation were presented and concluded that the enhancement of overall heat transfer coefficient is likely to be feasible by means of increasing the mass flow rate of base fluid and prepared nanofluid on the proportional basis.


Sign in / Sign up

Export Citation Format

Share Document