Design of One-Piece Jet-Engine Compressor End Seals

1968 ◽  
Vol 90 (4) ◽  
pp. 709-721
Author(s):  
L. W. Winn ◽  
R. L. Thorkildsen ◽  
D. F. Wilcock

Performance of advanced air-breathing propulsion systems can be significantly improved through the utilization of effective sealing devices. One of the areas in which immediate benefits are realizable from improvements in sealing efficiency is the high-pressure compressor end area. This paper describes the design of a face-type flexible seal and a face-type rigid seal for a compressor end seal based upon the cruise conditions expected in one version of the supersonic transport (SST) jet engine. The seals, non-contacting during operation, operate on air films achieved through the employment of hybrid gas-bearing geometries on the seal faces. The design procedure discussed consists primarily of the selection of the most applicable seal-face geometries force and moment balance, determination of seal tracking capability, establishment of leakage characteristics, thermal gradients, and stress and deflection calculations. The design results indicate that satisfactory seal performance can be obtained with either of the two configurations. Leakage reductions of an order of magnitude compared to that encountered with labyrinth seals commonly used in existing jet-engine systems can be achieved.

2017 ◽  
Vol 17 ◽  
pp. 245-252
Author(s):  
V. V. Somov

In carrying out an investigation into the explosion, among others, the investigative version of the use of a single-use reactive grenade launcher is being considered. The most common for criminal explosions are applied grenade launchers RPG-18, RPG-22, RPG-26. Their use is due to a number of such properties as small size and weight, which makes it possible to transfer them covertly, the range of the shot significantly exceeding the range of the hand grenade throw, the high detonating effect of the rocket grenade explosion. The single-use rocket launchers are generally of the same design. Their differences are in the features of the components construction and dimensional characteristics, which are given in the article. On the basis of expert practice, details ofgrenade launchers that remain at the site of the explosion and have the least damage are determined. These details are the objects of investigation of the explosion technical expertise. These objects include launchers of grenade launchers and rocket parts ofjet grenades. The design features of the launchers, their dimensional characteristics and marking symbols make it possible to determine their belonging to a specific type of jet grenade launchers. Missile parts of jet grenades differ in the form of the combustion chamber of the jet engine, nozzle, in the size ofthe outlet section of the nozzle, in the form and size of the stabilizerfeathers. To determine the belonging of the rocket part of the grenade to a specific type ofjet grenade launcher, it’s necessary to establish a set of structural features and dimensional characteristics. At considerable damage of the combustion chamber of the jet engine, as a rule, the nozzle block remains intact that allows to define diameter of critical section of a nozzle, and on it to establish type of the used single-use grenade launcher.


2019 ◽  
Vol 7 (2A) ◽  
Author(s):  
Camilo Fuentes Serrano ◽  
Juan Reinaldo Estevez Alvares ◽  
Alfredo Montero Alvarez ◽  
Ivan Pupo Gonzales ◽  
Zahily Herrero Fernandez ◽  
...  

A method for determination of Cr, Fe, Co, Ni, Cu, Zn, Hg and Pb in waters by Energy Dispersive X Ray Fluorescence (EDXRF) was implemented, using a radioisotopic source of 238Pu. For previous concentration was employed a procedure including a coprecipitation step with ammonium pyrrolidinedithiocarbamate (APDC) as quelant agent, the separation of the phases by filtration, the measurement of filter by EDXRF and quantification by a thin layer absolute method. Sensitivity curves for K and L lines were obtained respectively. The sensitivity for most elements was greater by an order of magnitude in the case of measurement with a source of 238Pu instead of 109Cd, which means a considerable decrease in measurement times. The influence of the concentration in the precipitation efficiency was evaluated for each element. In all cases the recoveries are close to 100%, for this reason it can be affirmed that the method of determination of the studied elements is quantitative. Metrological parameters of the method such as trueness, precision, detection limit and uncertainty were calculated. A procedure to calculate the uncertainty of the method was elaborated; the most significant source of uncertainty for the thin layer EDXRF method is associated with the determination of instrumental sensitivities. The error associated with the determination, expressed as expanded uncertainty (in %), varied from 15.4% for low element concentrations (2.5-5 μg/L) to 5.4% for the higher concentration range (20-25 μg/L).


Molecules ◽  
2021 ◽  
Vol 26 (5) ◽  
pp. 1238
Author(s):  
Eduardo Laga ◽  
David Dalmau ◽  
Sofía Arregui ◽  
Olga Crespo ◽  
Ana I. Jimenez ◽  
...  

The goal of the work reported here was to amplify the fluorescent properties of 4-aryliden-5(4H)-oxazolones by suppression of the hula-twist non-radiative deactivation pathway. This aim was achieved by simultaneous bonding of a Pd center to the N atom of the heterocycle and the ortho carbon of the arylidene ring. Two different 4-((Z)-arylidene)-2-((E)-styryl)-5(4H)-oxazolones, the structures of which are closely related to the chromophore of the Kaede protein and substituted at the 2- and 4-positions of the arylidene ring (1a OMe; 1b F), were used as starting materials. Oxazolones 1a and 1b were reacted with Pd(OAc)2 to give the corresponding dinuclear orthometalated palladium derivates 2a and 2b by regioselective C–H activation of the ortho-position of the arylidene ring. Reaction of 2a (2b) with LiCl promoted the metathesis of the bridging carboxylate by chloride ligands to afford dinuclear 3a (3b). Mononuclear complexes containing the orthopalladated oxazolone and a variety of ancillary ligands (acetylacetonate (4a, 4b), hydroxyquinolinate (5a), aminoquinoline (6a), bipyridine (7a), phenanthroline (8a)) were prepared from 3a or 3b through metathesis of anionic ligands or substitution of neutral weakly bonded ligands. All species were fully characterized and the X-ray determination of the molecular structure of 7a was carried out. This structure has strongly distorted ligands due to intramolecular interactions. Fluorescence measurements showed an increase in the quantum yield (QY) by up to one order of magnitude on comparing the free oxazolone (QY < 1%) with the palladated oxazolone (QY = 12% for 6a). This fact shows that the coordination of the oxazolone to the palladium efficiently suppresses the hula-twist deactivation pathway.


1997 ◽  
Vol 12 (11) ◽  
pp. 1967-1974 ◽  
Author(s):  
Kazuaki Kuroda ◽  
Mark A. Barton ◽  
Atsushi Onae ◽  
Yukinobu Miki

We propose the application of a new technique, the X pendulum, to determine the Newtonian gravitational constant G. We evaluate the likely experimental errors for configurations realizable with existing technologies and show that improvement of the accuracy by an order of magnitude or more is possible.


2002 ◽  
Vol 18 (1) ◽  
pp. 1-17 ◽  
Author(s):  
K. Anastassiadis ◽  
I. E. Avramidis ◽  
P. Panetsos

According to the model of Penzien and Watabe, the three translational ground motion components on a specific point of the ground are statistically noncorrelated along a well-defined orthogonal system of axes p, w, and v, whose orientation remains reasonably stable over time during the strong motion phase of an earthquake. This orthotropic ground motion is described by three generally independent response spectra Sa, Sb, and Sc, respectively. The paper presents an antiseismic design procedure for structures according to the above seismic motion model. This design includes a) determination of the critical orientation of the seismic input, i.e., the orientation that gives the largest response, b) calculation of the maximum and the minimum values of any response quantity, and c) application of either the Extreme Stress Method or the Extreme Force Method for determining the most unfavorable combinations of several stress resultants (or sectional forces) acting concurrently at a specified section of a structural member.


2021 ◽  
Author(s):  
Larisa A. Chipiga ◽  
Anna E. Petrova ◽  
Artem A. Mosunov ◽  
Laura T. Naurzbaeva ◽  
Stanislaus M. Kushnarenko ◽  
...  

In connection with the constantly increasing use of monoclonal antibodies labeled with 89Zr, in clinical practice, it is urgent to study their pharmacokinetics with the determination, based on the data obtained, of absorbed doses in tumor foci, as well as intact organs and tissues, and effective doses of patients. To date, there are a limited number of studies that provide patient doses for diagnostic examinations using 89Zr-labeled monoclonal antibodies. In this regard, the purpose of this work was to assess the biodistribution of various monoclonal antibodies (ramucirumab, trastuzumab, atezolizumab) labeled with 89Zr, based on published data, with subsequent calculation of absorbed doses in radiosensitive organs and tissues and effective doses of patients. Based on the analysis of experimental data on the biodistribution of monoclonal antibodies labeled with 89Zr for the diagnosis of oncological diseases from the available literature sources and our own assessments, it has been concluded that the results of the determination of absorbed in organs and tissues and effective doses are inconsistent. The absorbed doses in organs, according to different literature sources, vary up to an order of magnitude within one organ and reach 440 mGy per examination, the effective dose varies from 3 to 112 mSv per examination. This may be due to differences in study design, radiometry and dose assessment methods. Comparison with doses obtained on the basis of a general model of biodistribution of monoclonal antibodies demonstrates the possibility of using this model for a rough estimate of internal doses of patients. However, for a more accurate assessment, it is necessary to standardize approaches to the determination of internal radiation doses using the most effective methodological solutions and software products.


Author(s):  
Eric Brehm ◽  
Robert Hertle ◽  
Markus Wetzel

In common structural design, random variables, such as material strength or loads, are represented by fixed numbers defined in design codes. This is also referred to as deterministic design. Addressing the random character of these variables directly, the probabilistic design procedure allows the determination of the probability of exceeding a defined limit state. This probability is referred to as failure probability. From there, the structural reliability, representing the survival probability, can be determined. Structural reliability thus is a property of a structure or structural member, depending on the relevant limit states, failure modes and basic variables. This is the basis for the determination of partial safety factors which are, for sake of a simpler design, applied within deterministic design procedures. In addition to the basic variables in terms of material and loads, further basic variables representing the structural model have to be considered. These depend strongly on the experience of the design engineer and the level of detailing of the model. However, in the clear majority of cases [1] failure does not occur due to unexpectedly high or low values of loads or material strength. The most common reasons for failure are human errors in design and execution. This paper will provide practical examples of original designs affected by human error and will assess the impact on structural reliability.


2004 ◽  
Vol 08 (11) ◽  
pp. 1311-1324 ◽  
Author(s):  
Maddalena Pizzotti ◽  
Elisabetta Annoni ◽  
Renato Ugo ◽  
Silvia Bruni ◽  
Silvio Quici ◽  
...  

A multitechnique investigation of the determination of the order of magnitude of the second and third order NLO response of [5-[(4-dimethylaminophenyl)ethynyl]-15-[(4-nitrophenyl)ethynyl]-10,20-diphenylporphyrinato]nickel(II) (1) is reported with the aim to produce self consistent evidence for a significant NLO response of this kind of push-pull porphyrin chromophore. The experimental multitechnique approach is based on the EFISH technique, working with a non-resonant incident wavelength of 1.907 μm, on the solvatochromic method and finally on a vibrational method, avoiding any fluorescence or resonance interference. A theoretical MNDO-TDHF evaluation of the zero-frequency quadratic and cubic hyperpolarizabilities of an ab initio optimized planar structure is also reported. The order of magnitude of the quadratic hyperpolarizability of (1) at zero frequency (β0), was found to be significantly lower than that reported for the corresponding Cu (II) or Zn (II) complexes with the same push-pull porphyrin chromophore.


2018 ◽  
Vol 57 (2) ◽  
pp. 238-243 ◽  
Author(s):  
Roberta Pacifici ◽  
Simona Pichini ◽  
Manuela Pellegrini ◽  
Roberta Tittarelli ◽  
Flaminia Pantano ◽  
...  

Abstract Background In those countries where cannabis use is still illegal, some manufacturers started producing and selling “light cannabis”: dried flowering tops containing the psychoactive principle Δ-9-tetrahydrocannabinol (THC) at concentrations lower than 0.2% together with variable concentration of cannabidiol (CBD). We here report a pilot study on the determination of cannabinoids in the oral fluid and urine of six individuals after smoking 1 g of “light cannabis”. Methods On site screening for oral fluid samples was performed, as a laboratory immunoassay test for urine samples. A validated gas chromatography-mass spectrometry (GC-MS) method was then applied to quantify THC and CBD, independently from results of screening tests. Results On site screening for oral fluid samples, with a THC cut-off of 25 ng/mL gave negative results for all the individuals at different times after smoking. Similarly, negative results for urine samples screening from all the individuals were obtained. Confirmation analyses showed that oral fluid THC was in the concentration range from 2.5 to 21.5 ng/mL in the first 30 min after smoking and then values slowly decreased. CBD values were usually one order of magnitude higher than those of THC. THC-COOH, the principal urinary THC metabolite, presented the maximum urinary value of 1.8 ng/mL, while urinary CBD had a value of 15.1 ng/mL. Conclusions Consumers of a single 1 g dose of “light cannabis” did not result as positive in urine screening, assessing recent consumption, so that confirmation would not be required. Conversely, they might result as positive to oral fluid testing with some on-site kits, with THC cut-off lower than 25 ng/mL, at least in the first hour after smoking and hence confirmation analysis can be then required. No conclusions can be drawn of eventual chronic users.


Sign in / Sign up

Export Citation Format

Share Document