Numerical Predictions of Heat Transfer to Supercritical Helium in Turbulent Flow Through Circular Tubes

1977 ◽  
Vol 99 (4) ◽  
pp. 580-585 ◽  
Author(s):  
N. M. Schnurr

A numerical method is used to calculate heat transfer to supercritical helium in turbulent flow through circular tubes with constant wall heat flux. Comparisons of numerical predictions to experimental data showed good agreement. Numerical results were obtained for pressures from 2.5 to 20 atm and these results were correlated in terms of a heat flux parameter. A preliminary study of heat transfer in the thermal entry region showed the increase of the film coefficient to be larger for higher heat fluxes and for cases where the inlet bulk enthalpy was above the pseudocritical value.

1976 ◽  
Vol 98 (4) ◽  
pp. 609-615 ◽  
Author(s):  
N. M. Schnurr ◽  
V. S. Sastry ◽  
A. B. Shapiro

A two-dimensional numerical method has been developed to predict heat transfer to near critical fluids in turbulent flow through circular tubes. The analysis is applicable to the thermal entry region as well as fully developed flows. Agreement with experimental data for water at 31.0 MN/m2 is quite good. A correlation in the form of the heat flux parameter of Goldmann was found to be satisfactory for water at that pressure. Results are presented in graphical form which apply to a wide range of heat fluxes, mass velocities, and tube diameters. Preliminary results in the entrance region show that film coefficients remain well above the corresponding fully developed values for a larger distance downstream than would be the case with a constant property fluid. This effect becomes more pronounced as the heat flux is increased.


2013 ◽  
Vol 455 ◽  
pp. 470-473
Author(s):  
Chao Wang ◽  
Shang Long Xu ◽  
Yun Chuan Wu

A study has been conducted on the heat transfer of various oscillatory frequencies of pulsation flow through a porous channel network subjected to a constant wall heat flux. The surface temperature distributions, pressure drop, unit thermal resistance and local Nusselt number for different oscillatory frequencies were mainly investigated.


2018 ◽  
Vol 54 (7) ◽  
pp. 2089-2099 ◽  
Author(s):  
S. Iyahraja ◽  
J. Selwin Rajadurai ◽  
S. Rajesh ◽  
R. Seeni Thangaraj Pandian ◽  
M. Selva Kumaran ◽  
...  

2011 ◽  
Vol 18 (6) ◽  
pp. 491-502 ◽  
Author(s):  
Andrew Mintu Sarkar ◽  
M. A. Rashid Sarkar ◽  
Mohammad Abdul Majid

2005 ◽  
Vol 12 (4) ◽  
pp. 385-394 ◽  
Author(s):  
M. A. Rashid Sarkar ◽  
M. Zaidul Islam ◽  
M. A. Islam

Fluids ◽  
2021 ◽  
Vol 6 (7) ◽  
pp. 246
Author(s):  
Rozie Zangeneh

The Wall-modeled Large-eddy Simulation (WMLES) methods are commonly accompanied with an underprediction of the skin friction and a deviation of the velocity profile. The widely-used Improved Delayed Detached Eddy Simulation (IDDES) method is suggested to improve the prediction of the mean skin friction when it acts as WMLES, as claimed by the original authors. However, the model tested only on flow configurations with no heat transfer. This study takes a systematic approach to assess the performance of the IDDES model for separated flows with heat transfer. Separated flows on an isothermal wall and walls with mild and intense heat fluxes are considered. For the case of the wall with heat flux, the skin friction and Stanton number are underpredicted by the IDDES model however, the underprediction is less significant for the isothermal wall case. The simulations of the cases with intense wall heat transfer reveal an interesting dependence on the heat flux level supplied; as the heat flux increases, the IDDES model declines to predict the accurate skin friction.


Author(s):  
V. G. Razumovskiy ◽  
Eu. N. Pis’mennyy ◽  
A. Eu. Koloskov ◽  
I. L. Pioro

The results of heat transfer to supercritical water flowing upward in a vertical annular channel (1-rod channel) and tight 3-rod bundle consisting of the tubes of 5.2-mm outside diameter and 485-mm heated length are presented. The heat-transfer data were obtained at pressures of 22.5, 24.5, and 27.5 MPa, mass flux within the range from 800 to 3000 kg/m2·s, inlet temperature from 125 to 352°C, outlet temperature up to 372°C and heat flux up to 4.6 MW/m2 (heat flux rate up to 2.5 kJ/kg). Temperature regimes of the annular channel and 3-rod bundle were stable and easily reproducible within the whole range of the mass and heat fluxes, even when a deteriorated heat transfer took place. The data resulted from the study could be applicable for a reference estimation of heat transfer in future designs of fuel bundles.


Author(s):  
Andreas Jeromin ◽  
Christian Eichler ◽  
Berthold Noll ◽  
Manfred Aigner

Numerical predictions of conjugate heat transfer on an effusion cooled flat plate were performed and compared to detailed experimental data. The commercial package CFX® is used as flow solver. The effusion holes in the referenced experiment had an inclination angle of 17 degrees and were distributed in a staggered array of 7 rows. The geometry and boundary conditions in the experiments were derived from modern gas turbine combustors. The computational domain contains a plenum chamber for coolant supply, a solid wall and the main flow duct. Conjugate heat transfer conditions are applied in order to couple the heat fluxes between the fluid region and the solid wall. The fluid domain contains 2.4 million nodes, the solid domain 300,000 nodes. Turbulence modeling is provided by the SST turbulence model which allows the resolution of the laminar sublayer without wall functions. The numerical predictions of velocity and temperature distributions at certain locations show significant differences to the experimental data in velocity and temperature profiles. It is assumed that this behavior is due to inappropriate modeling of turbulence especially in the effusion hole. Nonetheless, the numerically predicted heat transfer coefficients are in good agreement with the experimental data at low blowing ratios.


Author(s):  
Jensen Hoke ◽  
Todd Bandhauer ◽  
Jack Kotovsky ◽  
Julie Hamilton ◽  
Paul Fontejon

Liquid-vapor phase change heat transfer in microchannels offers a number of significant advantages for thermal management of high heat flux laser diodes, including reduced flow rates and near constant temperature heat rejection. Modern laser diode bars can produce waste heat loads >1 kW cm−2, and prior studies show that microchannel flow boiling heat transfer at these heat fluxes is possible in very compact heat exchanger geometries. This paper describes further performance improvements through area enhancement of microchannels using a pyramid etching scheme that increases heat transfer area by ∼40% over straight walled channels, which works to promote heat spreading and suppress dry-out phenomenon when exposed to high heat fluxes. The device is constructed from a reactive ion etched silicon wafer bonded to borosilicate to allow flow visualization. The silicon layer is etched to contain an inlet and outlet manifold and a plurality of 40μm wide, 200μm deep, 2mm long channels separated by 40μm wide fins. 15μm wide 150μm long restrictions are placed at the inlet of each channel to promote uniform flow rate in each channel as well as flow stability in each channel. In the area enhanced parts either a 3μm or 6μm sawtooth pattern was etched vertically into the walls, which were also scalloped along the flow path with the a 3μm periodicity. The experimental results showed that the 6μm area-enhanced device increased the average maximum heat flux at the heater to 1.26 kW cm2 using R134a, which compares favorably to a maximum of 0.95 kw cm2 dissipated by the plain walled test section. The 3μm area enhanced test sections, which dissipated a maximum of 1.02 kW cm2 showed only a modest increase in performance over the plain walled test sections. Both area enhancement schemes delayed the onset of critical heat flux to higher heat inputs.


Sign in / Sign up

Export Citation Format

Share Document