Transient Pool Boiling Heat Transfer—Part 2: Boiling Heat Transfer and Burnout

1977 ◽  
Vol 99 (4) ◽  
pp. 554-560 ◽  
Author(s):  
A. Sakurai ◽  
M. Shiotsu

Transient boiling heat transfer for exponential heat input to a platinum wire supported horizontally in a pool of water was investigated. Transient boiling heat transfer coefficient, transient DNB heat flux, and transient maximum heat flux were obtained for exponential periods ranging from 5 ms to 10 s and for system pressures ranging from 0.1 to 2.1 MPa. Transient boiling heat transfer coefficient after the commencement of boiling becomes lower than the steady boiling heat transfer coefficient at the same heat flux. This was explained to be as a result of the time lag of the activation of originally flooded cavities for the increasing rate of the heat input. Initial heat flux was varied from zero to near the steady maximum heat flux. Effect of initial boiling condition on transient DNB and maximum heat fluxes was negligible. Mechanism of transient boiling heat transfer beyond steady DNB heat flux was suggested.

1990 ◽  
Vol 112 (3) ◽  
pp. 736-743 ◽  
Author(s):  
V. X. Tung ◽  
V. K. Dhir

Boiling heat transfer from a sphere embedded in a porous medium composed of nonheated glass particles was studied under steady-state and transient quenching conditions. In the experiments, the diameter of the nonheated glass particles forming the porous layers was varied parametrically. Freon-113 was used as the test liquid. Experimental results showed that the maximum heat flux increased monotonically with increasing glass particle diameter and approached an asymptotic value corresponding to the maximum heat flux obtained in a pool free of glass particles. It was also observed that the minimum heat flux was nearly insensitive to the particle size and the film boiling heat transfer coefficient increased slightly with decreasing particle size. In the nucleate boiling region, the heat transfer coefficient showed a much weaker dependence on wall superheat in the presence of particles. Transient data indicated that the surface temperature was not uniform during quenching. Therefore, different maximum heat fluxes were obtained depending on the location of the thermocouple whose temperature history was employed in recovering the transient boiling curve. However, for some applications, cooling rates predicted by imposing the steady-state boiling curve may not be in large error.


Author(s):  
Audrius Jasiulevicius ◽  
Rafael Macian-Juan

This paper presents the results of the assessment and analysis of TRACE v4.160 heat transfer predictions in the post-CHF (critical heat flux) region and discusses the possibilities to improve the TRACE v4.160 code predictions in the film boiling heat transfer when applying different film boiling correlations. For this purpose, the TRACE v4.160-calculated film boiling heat flux and the resulting maximum inner wall temperatures during film boiling in single tubes were compared with experimental data obtained at the Royal Institute of Technology (KTH) in Stockholm, Sweden. The experimental database included measurements for pressures ranging from 30 to 200 bar and coolant mass fluxes from 500 to 3000 kg/m2s. It was found that TRACE v4.160 does not produce correct predictions of the film boiling heat flux, and consequently of the maximum inner wall temperature in the test section, under the wide range of conditions documented in the KTH experiments. In particular, it was found that the standard TRACE v4.160 underpredicts the film boiling heat transfer coefficient at low pressure-low mass flux and high pressure-high mass flux conditions. For most of the rest of the investigated range of parameters, TRACE v4.160 overpredicts the film boiling heat transfer coefficient, which can lead to non-conservative predictions in applications to nuclear power plant analyses. Since no satisfactory agreement with the experimental database was obtained with the standard TRACE v4.160 film boiling heat transfer correlations, we have added seven film boiling correlations to TRACE v4.160 in order to investigate the possibility to improve the code predictions for the conditions similar to the KTH tests. The film boiling correlations were selected among the most commonly used film boiling correlations found in the open literature, namely Groeneveld 5.7, Bishop (2 correlations), Tong, Konkov, Miropolskii and Groeneveld-Delorme correlations. The only correlation among the investigated, which resulted in a significant improvement of TRACE predictions, was the Groeneveld 5.7. It was found, that replacing the current film boiling correlation (Dougall-Rohsenow) for the wall-togas heat transfer with Groeneveld 5.7 improves the code predictions for the film boiling heat transfer at high qualities in single tubes in the entire range of pressure and coolant mass flux considered.


2015 ◽  
Vol 138 (3) ◽  
Author(s):  
Steve Q. Cai ◽  
Avijit Bhunia

In a heat pipe, operating fluid saturates wick structures system and establishes a capillary-driven circulation loop for heat transfer. Thus, the thermophysical properties of the operating fluid inevitably impact the transitions of phase-change mode and the capability of heat transfer, which determine both the design and development of the associated heat pipe systems. This article investigates the effect of liquid properties on phase-change heat transfer. Two different copper wick structures, cubic and cylindrical in cross section, 340 μm in height and 150 μm in diameter or width, are fabricated using an electroplating technique. The phase-change phenomena inside these wick structures are observed at various heat fluxes. The corresponding heat transfer characteristics are measured for three different working liquids: water, ethanol, and Novec 7200. Three distinct modes of the phase-change process are identified: (1) evaporation on liquid–vapor interface, (2) nucleate boiling with interfacial evaporation, and (3) boiling enhanced interface evaporation. Transitions between the three modes depend on heat flux and liquid properties. In addition to the mode transition, liquid properties also dictate the maximum heat flux and the heat transfer coefficient. A quantitative characterization shows that the maximum heat flux scales with Merit number, a dimensionless number connecting liquid density, surface tension, latent heat of vaporization, and viscosity. The heat transfer coefficient, on the other hand, is dictated by the thermal conductivity of the liquid. A complex interaction between the mode transition and liquid properties is reflected in Novec 7200. In spite of having the lowest thermal conductivity among the three liquids, an early transition to the mode of the boiling enhanced interface evaporation leads to a higher heat transfer coefficient at low heat flux.


Author(s):  
K. S. Park ◽  
W. H. Choo ◽  
K. H. Bang

The flow boiling heat transfer coefficient of R-22 in small hydraulic diameter tubes has been experimentally studied. Both brass and aluminum round tubes of 1.66 mm inside diameter are used for the test section. The ranges of the major experimental parameters are 300∼600 kg/m2s of refrigerant mass flux, 10∼20 kW/m2 of the wall heat flux, 0.0∼0.9 of the inlet vapor quality. The experimental result showed that the flow boiling heat transfer coefficient in this small tubes are in the range of 2∼4 kW/m2K and it varies only by heat flux, independent of mass flux and vapor quality. It is also observed that the heat transfer coefficients in the aluminum tube are up to 50% higher than in the brass tube.


Author(s):  
Chen Li ◽  
G. P. Peterson ◽  
Yaxiong Wang

Evaporation/boiling from surfaces coated with multiple, uniform layers of sintered, isotropic, copper-mesh is studied experimentally. The investigation focuses on the effect of the wick thickness on the steady-state evaporation/boiling heat transfer coefficient and the critical heat flux under atmospheric pressure conditions. An optimal sintering process was developed and employed to prepare the test articles. This process minimizes the interface thermal contact resistance between the heated wall and wick, as well as enhancing the contact conditions between the layers of copper mesh. Due to the reduction in the thermal contact resistance between the wall and copper mesh, extremely high evaporation/boiling heat transfer coefficients were achieved. These values, which varied with input heat flux and wick thickness, were from 5 to 20 times higher than those previously reported by other researchers. The critical heat flux (CHF) was also significantly enhanced. The experimental results also indicated that while the evaporation/boiling heat transfer coefficient is not affected by wick thickness, the CHF for steady-state operation is strongly dependent on the wick layer thickness. In addition, the CHF increases proportionally with the wick thickness when the wick structure, porosity and pore size are held constant. Sample structure and fabrication processes as well as test procedures are described and discussed in detail and the experimental results and observations are systematically presented and analyzed. Evaporation/boiling Heat transfer regimes from these wick structures are identified and discussed based on the visual observations of the phase-change phenomena and the relative relationship between the heat flux and superheat.


2012 ◽  
Vol 18 (1) ◽  
pp. 11-18 ◽  
Author(s):  
M.M. Sarafraz ◽  
S.A. Alavi-Fazel ◽  
Y. Hasanzadeh ◽  
A. Arabshamsabadi ◽  
S. Bahram

Pool boiling heat transfer coefficient of monoethylene glycol (MEG), diethylene glycol (DEG) and water ternary mixtures has been experimentally measured up to heat flux 114 kW/m2 at various volumetric concentrations of MEG and DEG. As expected, heat transfer coefficient was strongly taken as a direct function of heat flux. Existing well-known correlations are shown to be unable to predict the acceptable values for the tested ternary mixtures, particularly at different concentrations of MEG and DEG. Furthermore, a new modified correlation is developed on the basis of the Stephan - Preu?er correlation that predicts the values of heat transfer coefficients with absolute average error of about 7% that is reasonable and acceptable values in compare to other existing correlations.


Sign in / Sign up