scholarly journals Experimental and Analytical Sonic Nozzle Discharge Coefficients for Reynolds Numbers up to 8×106

1975 ◽  
Vol 97 (4) ◽  
pp. 521-525 ◽  
Author(s):  
A. J. Szaniszlo

Sonic discharge coefficients are presented for two different geometry flow nozzles using nitrogen gas at high pressures (100 atm (100 × 105N/m2)) where real-gas corrections are significant. Throat Reynolds number range extended up to 8 × 106. Experimentally obtained coefficients for a nozzle with a continuous and finite radius of curvature agreed with those obtained analytically to within 0.2 percent. Experimental coefficients for a long-radius ASME nozzle agreed to within 1/4 percent to an empirical equation representing the most probable subsonic discharge coefficient.

2013 ◽  
Vol 136 (1) ◽  
Author(s):  
Noriyuki Furuichi ◽  
Kar-Hooi Cheong ◽  
Yoshiya Terao ◽  
Shinichi Nakao ◽  
Keiji Fujita ◽  
...  

The throat tap nozzle of the American Society of Mechanical Engineers performance test code (ASME PTC) 6 is widely used in engineering fields, and its discharge coefficient is normally estimated by an extrapolation in Reynolds number range higher than the order of 107. The purpose of this paper is to propose a new relation between the discharge coefficient of the throat tap nozzle and Reynolds number by a detailed analysis of the experimental data and the theoretical models, which can be applied to Reynolds numbers up to 1.5 × 107. The discharge coefficients are measured for several tap diameters in Reynolds numbers ranging from 2.4 × 105 to 1.4 × 107 using the high Reynolds number calibration rig of the National Metrology Institute of Japan (NMIJ). Experimental results show that the discharge coefficients depend on the tap diameter and the deviation between the experimental results and the reference curve of PTC 6 is 0.75% at maximum. New equations to estimate the discharge coefficient are developed based on the experimental results and the theoretical equations including the tap effects. The developed equations estimate the discharge coefficient of the present experimental data within 0.21%, and they are expected to estimate more accurately the discharge coefficient of the throat tap nozzle of PTC 6 than the reference curve of PTC 6.


1965 ◽  
Vol 180 (1) ◽  
pp. 331-356 ◽  
Author(s):  
L. J. Kastner ◽  
J. C. McVeigh

In view of the importance of accurate measurement of flow rate at low Reynolds numbers, there have been numerous attempts to develop metering devices having constant discharge coefficients in the range of pipe Reynolds numbers between about 3000 and 200 and even below this latter value, and some of these attempts have achieved a reasonable degrees of success. Nevertheless, some confusion exists regarding the dimensions and range of utility of certain designs which have been recommended and further information is necessary in order that the situation may be clarified. The aims of the present investigation, which is believed to be wider in scope than any published in this field in recent years, were to review and correlate existing knowledge and to make an experimental study of the properties of various types of orifice in the low range of Reynolds numbers. Arising from this it was hoped that a design might be evolved which not only had a satisfactorily constant discharge coefficient throughout the range but was also simple to manufacture and reproduce, even for small orifice diameters of the order of 0.5 in or less, and it is believed that some success in attaining this aim was achieved. The first section of the paper contains a review of previous investigations classified into three main groups. In the second part of the paper, experiments with various types of orifice plate are described and it is shown that a properly proportioned single-bevelled orifice has as good a performance in the low Reynolds number range as that of any of the more complicated shapes.


Author(s):  
Noriyuki Furuichi ◽  
KarHooi Cheong ◽  
Yoshiya Terao ◽  
Shinichi Nakao ◽  
Keiji Fujita ◽  
...  

The high accurate throat tap flow nozzle with four different diameter taps is developed and its discharge coefficients are measured in the Reynolds number range from 1.5×106 to 1.4×107 using the high Reynolds calibration facility of AIST,NMIJ. The discharge coefficient of a throat tap nozzle extrapolated according to ASME PTC 6 are confirmed to deviate 0.37% at Red=1.4×107 from the experimental results. The high accurate flow nozzle developed can reduce this extrapolation error of the discharge coefficient to high Reynolds numbers by using the equations of discharge coefficients, which is determined as a function of Reynolds number and tap diameter based on the experimental results of four different diameter taps. The error of extrapolated discharge coefficient using the derived equations is estimated to be less than 0.1% at Red=1.4×107. The present results show that the throat tap flow nozzle developed is expected to work as a high accurate flowmeter even under the extrapolation of the discharge coefficient toward high Reynolds numbers.


Author(s):  
Noriyuki Furuichi ◽  
Kar-Hooi Cheong ◽  
Yoshiya Terao ◽  
Shinichi Nakao ◽  
Keiji Fujita ◽  
...  

Discharge coefficients for three flow nozzles based on ASME PTC 6 are measured under many flow conditions at AIST, NMIJ and PTB. The uncertainty of the measurements is from 0.04% to 0.1% and the Reynolds number range is from 1.3×105 to 1.4×107. The discharge coefficients obtained by these experiments is not exactly consistent to one given by PTC 6 for all examined Reynolds number range. The discharge coefficient is influenced by the size of tap diameter even if at the lower Reynolds number region. Experimental results for the tap of 5 mm and 6 mm diameter do not satisfy the requirements based on the validation procedures and the criteria given by PTC 6. The limit of the size of tap diameter determined in PTC 6 is inconsistent with the validation check procedures of the calibration result. An enhanced methodology including the term of the tap diameter is recommended. Otherwise, it is recommended that the calibration test should be performed at as high Reynolds number as possible and the size of tap diameter is desirable to be as small as possible to obtain the discharge coefficient with high accuracy.


Author(s):  
Noriyuki Furuichi ◽  
Yoshiya Terao ◽  
Shinichi Nakao ◽  
Keiji Fujita ◽  
Kazuo Shibuya

The discharge coefficients of the throat tap flow nozzle based on ASME PTC 6 are measured in wide Reynolds number range from Red=5.8×104 to Red=1.4×107. The nominal discharge coefficient (the discharge coefficient without tap) is determined from the discharge coefficients measured for different tap diameters. The tap effects are correctly obtained by subtracting the nominal discharge coefficient from the discharge coefficient measured. Finally, by combing the nominal discharge coefficient and the tap effect determined in three flow regions, that is, laminar, transitional and turbulent flow region, the new equations of the discharge coefficient are proposed in three flow regions.


2004 ◽  
Vol 126 (4) ◽  
pp. 803-808 ◽  
Author(s):  
M. Dittmann ◽  
K. Dullenkopf ◽  
S. Wittig

The secondary air system of modern gas turbine engines consists of numerous stationary or rotating passages to transport the cooling air, taken from the compressor, to thermally high loaded components that need cooling. Thereby the cooling air has to be metered by orifices to control the mass flow rate. Especially the discharge behavior of rotating holes may vary in a wide range depending on the actual geometry and the operating point. The exact knowledge of the discharge coefficients of these orifices is essential during the design process in order to guarantee a well adapted distribution of the cooling air inside the engine. This is crucial not only for a safe and efficient operation but also fundamental to predict the component’s life and reliability. In this paper two different methods to correlate discharge coefficients of rotating orifices are described and compared, both in the stationary and rotating frame of reference. The benefits of defining the discharge coefficient in the relative frame of reference will be pointed out. Measurements were conducted for two different length-to-diameter ratios of the orifices with varying inlet geometries. The pressure ratio across the rotor was varied for rotational Reynolds numbers up to ReΦ=8.6×105. The results demonstrate the strong influence of rotation on the discharge coefficient. An analysis of the complete data shows significant optimizing capabilities depending on the orifice geometry.


1975 ◽  
Vol 97 (4) ◽  
pp. 576-581 ◽  
Author(s):  
R. P. Benedict ◽  
J. S. Wyler ◽  
G. B. Brandt

The effect of inlet edge roundness on the discharge coefficient of an orifice plate is studied experimentally. Several methods for measuring edge roundness are discussed and applied. An optical method in particular is shown to provide reliable measurements of edge roundness. Flow results are summarized in terms of radius of curvature by the empirical equation ΔCD/CD = 0.85 ln (rk/d × 103) + 1.74.


Author(s):  
M. Dittmann ◽  
K. Dullenkopf ◽  
S. Wittig

The secondary air system of modern gas turbine engines consists of numerous stationary or rotating passages to transport the cooling air, taken from the compressor, to thermally high loaded components that need cooling. Thereby the cooling air has to be metered by orifices to control the mass flow rate. Especially the discharge behavior of rotating holes may vary in a wide range depending on the actual geometry and the operating point. The exact knowledge of the discharge coefficients of these orifices is essential during the design process in order to guarantee a well adapted distribution of the cooling air inside the engine. This is crucial not only for a safe and efficient operation but also fundamental to predict the component’s life and reliability. In this paper two different methods to correlate discharge coefficients of rotating orifices are described and compared, both in the stationary and rotating frame of reference. The benefits of defining the discharge coefficient in the relative frame of reference will be pointed out. Measurements were conducted for two different length-to-diameter ratios of the orifices with varying inlet geometries. The pressure ratio across the rotor was varied for rotational Reynolds numbers up to Reφ = 8:6 × 105. The results demonstrate the strong influence of rotation on the discharge coefficient. An analysis of the complete data shows significant optimising capabilities depending on the orifice geometry.


Sign in / Sign up