Back Flow in Turbines of Nuclear Closed-Cycle Gas Turbine Plants in Case of Circuit Pipe Rupture

1975 ◽  
Vol 97 (2) ◽  
pp. 189-194 ◽  
Author(s):  
K. Bammert ◽  
P. Zehner

For operation of a gas turbine in single-cycle arrangement with a high-temperature reactor, rupture of a main circuit pipe has to be included in the safety considerations. In the event of such an accident there may be a back flow through the turbo machines or a forward flow up to the choking limit. This paper is a report on tests carried out in a two-dimensional cascade wind tunnel on turbine cascades under back flow conditions. By the example of three selected representative cascades the characteristic features in turbine cascades with back flow are discussed. These cascades are a rotor blade tip section with aerofoil-like profiles and a wide pitch, a stator blade or rotor blade mean section with an usual deflection and a rotor blade root section with a narrow pitch and a large deflection.

Author(s):  
Gm S. Azad ◽  
Je-Chin Han ◽  
Robert J. Boyle

Experimental investigations are performed to measure the detailed heat transfer coefficient and static pressure distributions on the squealer tip of a gas turbine blade in a five-bladed stationary linear cascade. The blade is a 2-dimensional model of a modern first stage gas turbine rotor blade with a blade tip profile of a GE-E3 aircraft gas turbine engine rotor blade. A squealer (recessed) tip with a 3.77% recess is considered here. The data on the squealer tip are also compared with a flat tip case. All measurements are made at three different tip gap clearances of about 1%, 1.5%, and 2.5% of the blade span. Two different turbulence intensities of 6.1% and 9.7% at the cascade inlet are also considered for heat transfer measurements. Static pressure measurements are made in the mid-span and near-tip regions, as well as on the shroud surface opposite to the blade tip surface. The flow condition in the test cascade corresponds to an overall pressure ratio of 1.32 and an exit Reynolds number based on the axial chord of 1.1×106. A transient liquid crystal technique is used to measure the heat transfer coefficients. Results show that the heat transfer coefficient on the cavity surface and rim increases with an increase in tip clearance. The heat transfer coefficient on the rim is higher than the cavity surface. The cavity surface has a higher heat transfer coefficient near the leading edge region than the trailing edge region. The heat transfer coefficient on the pressure side rim and trailing edge region is higher at a higher turbulence intensity level of 9.7% over 6.1% case. However, no significant difference in local heat transfer coefficient is observed inside the cavity and the suction side rim for the two turbulence intensities. The squealer tip blade provides a lower overall heat transfer coefficient when compared to the flat tip blade.


2000 ◽  
Vol 122 (4) ◽  
pp. 717-724 ◽  
Author(s):  
Gm. S. Azad ◽  
Je-Chin Han ◽  
Shuye Teng ◽  
Robert J. Boyle

Heat transfer coefficient and static pressure distributions are experimentally investigated on a gas turbine blade tip in a five-bladed stationary linear cascade. The blade is a two-dimensional model of a first-stage gas turbine rotor blade with a blade tip profile of a GE-E3 aircraft gas turbine engine rotor blade. The flow condition in the test cascade corresponds to an overall pressure ratio of 1.32 and exit Reynolds number based on axial chord of 1.1×106. The middle 3-blade has a variable tip gap clearance. All measurements are made at three different tip gap clearances of about 1, 1.5, and 2.5 percent of the blade span. Heat transfer measurements are also made at two different turbulence intensity levels of 6.1 and 9.7 percent at the cascade inlet. Static pressure measurements are made in the midspan and the near-tip regions as well as on the shroud surface, opposite the blade tip surface. Detailed heat transfer coefficient distributions on the plane tip surface are measured using a transient liquid crystal technique. Results show various regions of high and low heat transfer coefficient on the tip surface. Tip clearance has a significant influence on local tip heat transfer coefficient distribution. Heat transfer coefficient also increases about 15–20 percent along the leakage flow path at higher turbulence intensity level of 9.7 over 6.1 percent. [S0889-504X(00)00404-9]


Author(s):  
Mohammad R. Saadatmand

The aerodynamic design process leading to the production configuration of a 14 stage, 16:1 pressure ratio compressor for the Taurus 70 gas turbine is described. The performance of the compressor is measured and compared to the design intent. Overall compressor performance at the design condition was found to be close to design intent. Flow profiles measured by vane mounted instrumentation are presented and discussed. The flow through the first rotor blade has been modeled at different operating conditions using the Dawes (1987) three-dimensional viscous code and the results are compared to the experimental data. The CFD prediction agreed well with the experimental data across the blade span, including the pile up of the boundary layer on the corner of the hub and the suction surface. The rotor blade was also analyzed with different grid refinement and the results were compared with the test data.


Author(s):  
Jae Su Kwak ◽  
Je-Chin Han

The detailed distributions of heat transfer coefficient and film cooling effectiveness on a gas turbine blade tip were measured using a hue detection based transient liquid crystal technique. Tests were performed on a five-bladed linear cascade with blow down facility. The blade was a 2-dimensional model of a first stage gas turbine rotor blade with a profile of the GE-E3 aircraft gas turbine engine rotor blade. The Reynolds number based on cascade exit velocity and axial chord length was 1.1 × 106 and the total turning angle of the blade was 97.7°. The overall pressure ratio was 1.32 and the inlet and exit Mach number were 0.25 and 0.59, respectively. The turbulence intensity level at the cascade inlet was 9.7%. The blade model was equipped with a single row of film cooling holes at both the tip portion along the camber line and near the tip region of the pressure-side. All measurements were made at the three different tip gap clearances of 1%, 1.5%, and 2.5% of blade span and the three blowing ratios of 0.5, 1.0, and 2.0. Results showed that, in general, heat transfer coefficient and film effectiveness increased with increasing tip gap clearance. As blowing ratio increased, heat transfer coefficient decreased, while film effectiveness increased. Results also showed that adding pressure-side coolant injection would further decrease blade tip heat transfer coefficient but increase film effectiveness.


Author(s):  
F. A. E. Breugelmans

This paper describes the high speed cascade program underway at the von Karman Institute Turbomachinery Laboratory in Belgium. The primary purpose of the program is to contribute to the understanding of turbomachinery flow problems at transonic and supersonic speeds. Supersonic axial flow rotor blade sections and subsonic stator blade sections are investigated in a high speed cascade facility. The paper describes the cascade facility, instrumentation, and blade sections investigated. The aerodynamic flow through high subsonic and supersonic cascade blades is discussed, and some data obtained in the cascade tunnel are compared with those obtained in a rotating machine. Several major problems of high speed cascade testing are discussed, although a final solution is not always presented.


Author(s):  
Koichi Yonezawa ◽  
Junichi Sakamoto ◽  
Kazuyasu Sugiyama ◽  
Shuichi Ohmori ◽  
Shuichi Umezawa

Abstract Influences of age-related deterioration on the increase in rotor tip gap width are discussed numerically. In the gas turbine examined in the present study, there are two kinds of geometries around the rotor blade tip. In the first stage, there is clearance between the blade tip and the casing without any seal structures. On the other hand, there is a shroud and seal fin on the rotor blade tip. The blade geometries were measured using a 3-D scanner in a working power plant, and the tip clearances were varied by changing the casing contour. Steady-state CFD simulations were carried out. Tip gap widths were varied by shifting the casing wall. For simplicity, the blade geometries were not changed. The influence of tip clearance was examined by changing the geometries in each stage separately. Boundary conditions were determined using the previously developed hybrid method of heat balance analysis and CFD simulation, which can simulate the operating conditions of a working gas turbine. The results showed that the turbine performance degradation could spread to the following stage. Observation of entropy fields revealed that the increase in the tip leakage flow affected the flow in the following nozzle, and the loss increased.


Author(s):  
A. A. Ameri ◽  
E. Steinthorsson

Predictions of the rate of heat transfer to the tip and shroud of a gas turbine rotor blade are presented. The simulations are performed with a multiblock computer code which solves the Reynolds Averaged Navier-Stokes equations. The effect of inlet boundary layer thickness as well as rotation rate on the tip and shroud heat transfer is examined. The predictions of the blade tip and shroud heat transfer are in reasonable agreement with the experimental measurements. Areas of large heat transfer rates are identified and physical reasoning for the phenomena presented.


Author(s):  
P. W. McDonald

Steady transonic flow through two-dimensional gas turbine cascades is efficiently predicted using a time-dependent formulation of the equations of motion. An integral representation of the equations has been used in which subsonic and supersonic regions of the flow field receive identical treatment. Mild shock structures are permitted to develop naturally without prior knowledge of their exact strength or position. Although the solutions yield a complete definition of the flow field, the primary aim is to produce airfoil surface pressure distributions for the design of aerodynamically efficient turbine blade contours. In order to demonstrate the accuracy of this method, computed airfoil pressure distributions have been compared to experimental results.


2015 ◽  
Vol 137 (9) ◽  
Author(s):  
A. Arisi ◽  
S. Xue ◽  
W. F. Ng ◽  
H. K. Moon ◽  
L. Zhang

In modern gas turbine engines, the blade tips and near-tip regions are exposed to high thermal loads caused by the tip leakage flow. The rotor blades are therefore carefully designed to achieve optimum work extraction at engine design conditions without failure. However, very often gas turbine engines operate outside these design conditions which might result in sudden rotor blade failure. Therefore, it is critical that the effect of such off-design turbine blade operation be understood to minimize the risk of failure and optimize rotor blade tip performance. In this study, the effect of varying the exit Mach number on the tip and near-tip heat transfer characteristics was numerically studied by solving the steady Reynolds averaged Navier Stokes (RANS) equation. The study was carried out on a highly loaded flat tip rotor blade with 1% tip gap and at exit Mach numbers of Mexit = 0.85 (Reexit = 9.75 × 105) and Mexit = 1.0 (Reexit = 1.15 × 106) with high freestream turbulence (Tu = 12%). The exit Reynolds number was based on the rotor axial chord. The numerical results provided detailed insight into the flow structure and heat transfer distribution on the tip and near-tip surfaces. On the tip surface, the heat transfer was found to generally increase with exit Mach number due to high turbulence generation in the tip gap and flow reattachment. While increase in exit Mach number generally raises he heat transfer over the whole blade surface, the increase is significantly higher on the near-tip surfaces affected by leakage vortex. Increase in exit Mach number was found to also induce strong flow relaminarization on the pressure side near-tip. On the other hand, the size of the suction surface near-tip region affected by leakage vortex was insensitive to changes in exit Mach number but significant increase in local heat transfer was noted in this region.


Sign in / Sign up

Export Citation Format

Share Document