Closure to “Discussion of ‘Combined Bending-Torsion Fatigue Reliability of AISI 4340 Steel Shafting With Kt = 2.34’” (1975, ASME J. Eng. Ind., 97, p. 760)

1975 ◽  
Vol 97 (2) ◽  
pp. 760-761
Author(s):  
Dimitri Kececioglu ◽  
Louie B. Chester ◽  
Thomas M. Dodge
1975 ◽  
Vol 97 (2) ◽  
pp. 748-760 ◽  
Author(s):  
Dimitri Kececioglu ◽  
Louie B. Chester ◽  
Thomas M. Dodge

Results generated by three, unique fatigue reliability research machines which can apply reversed bending loads combined with steady torque are presented. Six-inch long, AISI 4340 steel, grooved specimens with a stress concentration factor of 2.34 and RC 35/40 hardness were subjected to various combinations of these loads and cycled to failure. The generated cycles-to-failure and stress-to-failure data are statistically analyzed to develop distributional S-N and Goodman diagrams. Various failure theories are investigated to determine which one represents the data best. The effect of the groove and of the various combined bending-torsion loads on the S-N and Goodman diagrams are determined. Three design applications are presented. The third one illustrates the weight savings that may be achieved by designing for reliability.


2017 ◽  
Vol 31 (2) ◽  
pp. 17 ◽  
Author(s):  
Sirsendu Mahata ◽  
Ankesh Samanta ◽  
Joydip Roy ◽  
Bijoy Mandal ◽  
Santanu Das

CORROSION ◽  
1969 ◽  
Vol 25 (8) ◽  
pp. 342-344 ◽  
Author(s):  
A. TIRMAN ◽  
E. G. HANEY ◽  
PAUL FUGASSI

Abstract The resistance to stress corrosion cracking of AISI 4340 steel foil in 0.6M aqueous sodium chloride, acidified to pH 1.5 with hydrochloric acid, is greatly decreased by prior treatment of the specimens for short periods of time with aqueous and nonaqueous solutions of sulfur, organic and inorganic sulfides, sulfur dioxides, and the inorganic salts of sulfurousand sulfuric acids. It is suggested that this prior treatment produces sulfided areas which are inhibitors of the combination of atomic hydrogen into molecular hydrogen. The decreased resistance to stress corrosion cracking is thus attributed to hydrogen embrittlement. If the stress corrosion cracking test is made in 0.6M aqueous sodium chloride, adjusted to an initial pH of 8, the effect of a prior sulfiding treatment is small. The formation of such sulfided areas in practice result from the exposure of 4340 steels to industrial atmospheres which may contain hydrogen sulfide, sulfur dioxide, and elemental sulfur.


Sign in / Sign up

Export Citation Format

Share Document