A Simple but Complete Solution for the Step Response of a Semi-Infinite, Circular Fluid Transmission Line

1972 ◽  
Vol 94 (2) ◽  
pp. 455-456 ◽  
Author(s):  
J. T. Karam

Presently, the only accurate solutions for the step response of a semi-infinite, circular fluid transmission line result from involved, time consuming, numerical finite series or integration techniques [1, 2, 3]. None of these solutions is practically suitable for either a rapid manual prediction for an arbitrary fluid line (liquid or gas), or for extension of the semi-infinite line results to the more meaningful problem of a finite line with arbitrary inputs. In the frequency domain (sinusoidal signals), a complete, verified solution exists [1, 4, 5] and theoretically could be transformed into the time domain. This was the scheme used by Brown and Nelson for liquid lines [2], but it required the numerical techniques referred to above and, in their own words, was a “very complex and tricky business.” However, simpler solutions for most operating regimes also exist in the frequency domain [6, 7]. These simple frequency domain solutions were transformed into the time domain and provided the basis for a simple solution for the step response.

1973 ◽  
Vol 95 (4) ◽  
pp. 498-504 ◽  
Author(s):  
J. T. Karam ◽  
R. G. Leonard

A simple, theoretically based time domain model for the propagation of small, arbitrary signals in a finite, circular, fluid transmission line is developed. A recent simple theoretical solution for the step response at a downstream point in a semi-infinite fluid line is combined with a two-port representation of a finite line. The major feature of this finite line model is two “filters” which represent a convolution of their arbitrary inputs with the unit impulse response at the equivalent location in a semi-infinite line. Experimental tests are reported which further verify the simple semi-infinite line solution and verify the response of several example systems containing finite lines. The models developed herein show good agreement with experiment. The major anomaly noted was an amplitude dependence in the experimental response for signals larger than one percent of the bulk modulus of the fluid. Since the theory represents a linearized, small perturbation model, such disagreement might have been anticipated and is viewed as a limitation, rather than invalidation, of the model. Finally, quantitative comparisons are made between the proposed model and those in current use.


2003 ◽  
Vol 40 (3) ◽  
pp. 220-229 ◽  
Author(s):  
Pedro L. D. Peres ◽  
Carlos R. de Souza ◽  
Ivanil S. Bonatti

The aim of this note is to show that all the behaviour of a two-wire transmission line can be directly derived from the application of ABCD matrix mathematical concepts, avoiding the explicit use of differential equations. An important advantage of this approach is that the transmission line modelling arises naturally in the frequency domain. Therefore the consideration of frequency-dependent parameters can be carried out in a simple way compared with the time-domain. Some standard examples of transmission lines are analysed through the use of ABCD matrices and a case study of a balun network is presented.


2020 ◽  
Vol 9 (1) ◽  
pp. 124-144
Author(s):  
Caglar Uyulan ◽  
Ersen Arslan

AbstractTrain safety and operational efficiency can be improved by investigating the dynamics of the train under varying conditions. Longitudinal train dynamics (LTD) simulations performed for such purposes, usually by utilising a nonlinear time-domain model. This paper covers two modes of LTD results corresponding to the time domain and frequency domain analysis. Time-domain solutions are essential to evaluate the full response used for parameter optimisation and controller design studies while frequency domain solutions can provide significant but straightforward clues regarding system dynamics. An advanced draft gear model, which works under a four-stage process is constructed considering all structural components, geometric relationships, friction modelling and dynamic characteristics such as hysteresis, stiffening, state transition, locked unloading, softening. Then, this model is parametrically reduced and implemented into an LTD simulation. The simulation in the time domain is conducted assuming a locomotive connected with a nine wagon via “ode3” fixed-step solver. The transfer function among the first wagon acceleration (output) and the locomotive force (input) estimated through system identification methodology. Then, the identification results interpreted by investigating step-response characteristic and best response giving parameter set is selected. Next, the modal and spectral analysis performed to reveal the behaviour of the in-train forces and the effects of vibration. This paper discusses a reliable methodology for the longitudinal dynamic analysis of the multi-bodied train in time and frequency domain and clarifies in-train vibration behaviour under the existence of sophisticated draft gear.


2018 ◽  
Vol 12 (7-8) ◽  
pp. 76-83
Author(s):  
E. V. KARSHAKOV ◽  
J. MOILANEN

Тhe advantage of combine processing of frequency domain and time domain data provided by the EQUATOR system is discussed. The heliborne complex has a towed transmitter, and, raised above it on the same cable a towed receiver. The excitation signal contains both pulsed and harmonic components. In fact, there are two independent transmitters operate in the system: one of them is a normal pulsed domain transmitter, with a half-sinusoidal pulse and a small "cut" on the falling edge, and the other one is a classical frequency domain transmitter at several specially selected frequencies. The received signal is first processed to a direct Fourier transform with high Q-factor detection at all significant frequencies. After that, in the spectral region, operations of converting the spectra of two sounding signals to a single spectrum of an ideal transmitter are performed. Than we do an inverse Fourier transform and return to the time domain. The detection of spectral components is done at a frequency band of several Hz, the receiver has the ability to perfectly suppress all sorts of extra-band noise. The detection bandwidth is several dozen times less the frequency interval between the harmonics, it turns out thatto achieve the same measurement quality of ground response without using out-of-band suppression you need several dozen times higher moment of airborne transmitting system. The data obtained from the model of a homogeneous half-space, a two-layered model, and a model of a horizontally layered medium is considered. A time-domain data makes it easier to detect a conductor in a relative insulator at greater depths. The data in the frequency domain gives more detailed information about subsurface. These conclusions are illustrated by the example of processing the survey data of the Republic of Rwanda in 2017. The simultaneous inversion of data in frequency domain and time domain can significantly improve the quality of interpretation.


2021 ◽  
Vol 9 (7) ◽  
pp. 781
Author(s):  
Shi He ◽  
Aijun Wang

The numerical procedures for dynamic analysis of mooring lines in the time domain and frequency domain were developed in this work. The lumped mass method was used to model the mooring lines. In the time domain dynamic analysis, the modified Euler method was used to solve the motion equation of mooring lines. The dynamic analyses of mooring lines under horizontal, vertical, and combined harmonic excitations were carried out. The cases of single-component and multicomponent mooring lines under these excitations were studied, respectively. The case considering the seabed contact was also included. The program was validated by comparing with the results from commercial software, Orcaflex. For the frequency domain dynamic analysis, an improved frame invariant stochastic linearization method was applied to the nonlinear hydrodynamic drag term. The cases of single-component and multicomponent mooring lines were studied. The comparison of results shows that frequency domain results agree well with nonlinear time domain results.


2002 ◽  
Vol 124 (4) ◽  
pp. 827-834 ◽  
Author(s):  
D. O. Baun ◽  
E. H. Maslen ◽  
C. R. Knospe ◽  
R. D. Flack

Inherent in the construction of many experimental apparatus designed to measure the hydro/aerodynamic forces of rotating machinery are features that contribute undesirable parasitic forces to the measured or test forces. Typically, these parasitic forces are due to seals, drive couplings, and hydraulic and/or inertial unbalance. To obtain accurate and sensitive measurement of the hydro/aerodynamic forces in these situations, it is necessary to subtract the parasitic forces from the test forces. In general, both the test forces and the parasitic forces will be dependent on the system operating conditions including the specific motion of the rotor. Therefore, to properly remove the parasitic forces the vibration orbits and operating conditions must be the same in tests for determining the hydro/aerodynamic forces and tests for determining the parasitic forces. This, in turn, necessitates a means by which the test rotor’s motion can be accurately controlled to an arbitrarily defined trajectory. Here in, an interrupt-driven multiple harmonic open-loop controller was developed and implemented on a laboratory centrifugal pump rotor supported in magnetic bearings (active load cells) for this purpose. This allowed the simultaneous control of subharmonic, synchronous, and superharmonic rotor vibration frequencies with each frequency independently forced to some user defined orbital path. The open-loop controller was implemented on a standard PC using commercially available analog input and output cards. All analog input and output functions, transformation of the position signals from the time domain to the frequency domain, and transformation of the open-loop control signals from the frequency domain to the time domain were performed in an interrupt service routine. Rotor vibration was attenuated to the noise floor, vibration amplitude ≈0.2 μm, or forced to a user specified orbital trajectory. Between the whirl frequencies of 14 and 2 times running speed, the orbit semi-major and semi-minor axis magnitudes were controlled to within 0.5% of the requested axis magnitudes. The ellipse angles and amplitude phase angles of the imposed orbits were within 0.3 deg and 1.0 deg, respectively, of their requested counterparts.


Author(s):  
Mansour Tabatabaie ◽  
Thomas Ballard

Dynamic soil-structure interaction (SSI) analysis of nuclear power plants is often performed in frequency domain using programs such as SASSI [1]. This enables the analyst to properly a) address the effects of wave radiation in an unbounded soil media, b) incorporate strain-compatible soil shear modulus and damping properties and c) specify input motion in the free field using the de-convolution method and/or spatially variable ground motions. For structures that exhibit nonlinearities such as potential base sliding and/or uplift, the frequency-domain procedure is not applicable as it is limited to linear systems. For such problems, it is necessary to solve the problem in the time domain using the direct integration method in programs such as ADINA [2]. The authors recently introduced a sub-structuring technique called distributed parameter foundation impedance (DPFI) model that allows the structure to be partitioned from the total SSI system and analyzed in the time domain while the foundation soil is modeled using the frequency-domain procedure [3]. This procedure has been validated for linear systems. In this paper we have expanded the DPFI model to incorporate nonlinearities at the soil/structure interface by introducing nonlinear shear and normal springs arranged in series between the DPFI and structure model. This combination of the linear far-field impedance (DPFI) plus nonlinear near-field soil springs allows the foundation sliding and/or uplift behavior be analyzed in time domain while maintaining the frequency-dependent stiffness and radiation damping nature of the far-field foundation impedance. To check the accuracy of this procedure, a typical NPP foundation mat supported at the surface of a layered soil system and subjected to harmonic forced vibration was first analyzed in the frequency domain using SASSI to calculate the target linear response and derive a linear, far-field DPFI model. The target linear solution was then used to validate two linear time-domain ADINA models: Model 1 consisting of the mat foundation+DPFI derived from the linear SASSI model and Model 2 consisting of the total SSI system (mat foundation plus a soil block). After linear alignment, the nonlinear springs were added to both ADINA models and re-analyzed in time domain. Model 2 provided the target nonlinear solution while Model 1 provided the results using the DPFI+nonlinear springs. By increasing the amplitude of the vibration load, different levels of foundation sliding were simulated. Good agreement between the results of two models in terms of the displacement response of the mat and cyclic force-displacement behavior of the springs validates the accuracy of the procedure presented herein.


2021 ◽  
Vol 3 (1) ◽  
pp. 031-036
Author(s):  
S. A. GOROVOY ◽  
◽  
V. I. SKOROKHODOV ◽  
D. I. PLOTNIKOV ◽  
◽  
...  

This paper deals with the analysis of interharmonics, which are due to the presence of a nonlinear load. The tool for the analysis was a mathematical apparatus - wavelet packet transform. Which has a number of advantages over the traditional Fourier transform. A simulation model was developed in Simulink to simulate a non-stationary non-sinusoidal mode. The use of the wavelet packet transform will allow to determine the mode parameters with high accuracy from the obtained wavelet coefficients. It also makes it possible to obtain information, both in the frequency domain of the signal and in the time domain.


Sign in / Sign up

Export Citation Format

Share Document