Some Results on the Heat Transfer Within Resonant Cavities at Subsonic and Supersonic Mach Numbers

1971 ◽  
Vol 93 (4) ◽  
pp. 537-542 ◽  
Author(s):  
R. A. White

An experimental investigation of the heat transfer within two cavities (L/D = 1.25 and 2.0) exhibiting self-induced pressure oscillations (commonly referred to as resonance) is discussed. The tests were conducted with free stream Mach numbers between 0.35 and 1.5 with corresponding unit Reynolds numbers of 33 × 105/ft to 41 × 105/ft. The approaching boundary layer and shear layer over the cavitieswere turbulent at all times. The pattern for the heat transfer coefficient distribution over the cavity walls is in good agreement with that found by other investigators. The effect of the self-induced pressure oscillations, however, is to cause large changes in the level of the heat transfer, with low values occurring at the distinctive peaks of the pressure oscillations. The ratio of the integrated heat transfer within the cavity to the heat transfer from a flat plate with area equal to the area of the cavity opening was found to vary from 1.10 to 0.40, depending on Mach number and cavity resonance conditions.

2019 ◽  
Vol 23 (4) ◽  
pp. 2413-2419 ◽  
Author(s):  
Haijun Li ◽  
Enhai Liu ◽  
Guanghui Zhou ◽  
Fengye Yang ◽  
Zhiyong Su ◽  
...  

This paper studies numerically the influence of the louver?s fin thickness on heat transfer and flow performance of a parallel flow evaporator, a comprehensive evaluation and analysis of the five structures at different Reynolds numbers are systematically carried out. Comparison of the numerical results with the experimental data shows good agreement with maximal errors of 12.16% and 5.29% for the heat transfer factor and the resistance factor, respectively. The results show that the heat transfer coefficient and the pressure drop increase with the increase of the thickness of the louver fins when the Reynolds number is a constant. The analysis of the comprehensive evaluation factor shows that the A-type fin is the best, and it can effectively strengthen the heat exchange on the air side and improve the heat transfer capacity of the system. The research results can provide reference for the structural optimization of the louver fins.


2005 ◽  
Vol 128 (6) ◽  
pp. 557-563 ◽  
Author(s):  
Paul L. Sears ◽  
Libing Yang

Heat transfer coefficients were measured for a solution of surfactant drag-reducing additive in the entrance region of a uniformly heated horizontal cylindrical pipe with Reynolds numbers from 25,000 to 140,000 and temperatures from 30to70°C. In the absence of circumferential buoyancy effects, the measured Nusselt numbers were found to be in good agreement with theoretical results for laminar flow. Buoyancy effects, manifested as substantially higher Nusselt numbers, were seen in experiments carried out at high heat flux.


Author(s):  
Anil K. Tolpadi ◽  
Michael E. Crawford

The heat transfer and aerodynamic performance of turbine airfoils are greatly influenced by the gas side surface finish. In order to operate at higher efficiencies and to have reduced cooling requirements, airfoil designs require better surface finishing processes to create smoother surfaces. In this paper, three different cast airfoils were analyzed: the first airfoil was grit blasted and codep coated, the second airfoil was tumbled and aluminide coated, and the third airfoil was polished further. Each of these airfoils had different levels of roughness. The TEXSTAN boundary layer code was used to make predictions of the heat transfer along both the pressure and suction sides of all three airfoils. These predictions have been compared to corresponding heat transfer data reported earlier by Abuaf et al. (1997). The data were obtained over a wide range of Reynolds numbers simulating typical aircraft engine conditions. A three-parameter full-cone based roughness model was implemented in TEXSTAN and used for the predictions. The three parameters were the centerline average roughness, the cone height and the cone-to-cone pitch. The heat transfer coefficient predictions indicated good agreement with the data over most Reynolds numbers and for all airfoils-both pressure and suction sides. The transition location on the pressure side was well predicted for all airfoils; on the suction side, transition was well predicted at the higher Reynolds numbers but was computed to be somewhat early at the lower Reynolds numbers. Also, at lower Reynolds numbers, the heat transfer coefficients were not in very good agreement with the data on the suction side.


Author(s):  
Shang-Feng Yang ◽  
Je-Chin Han ◽  
Salam Azad ◽  
Ching-Pang Lee

This paper experimentally investigates the effect of rotation on heat transfer in typical turbine blade serpentine coolant passage with ribbed walls at low Mach numbers. To achieve the low Mach number (around 0.01) condition, pressurized Freon R-134a vapor is utilized as the working fluid. The flow in the first passage is radial outward, after the 180 deg tip turn the flow is radial inward to the second passage, and after the 180 deg hub turn the flow is radial outward to the third passage. The effects of rotation on the heat transfer coefficients were investigated at rotation numbers up to 0.6 and Reynolds numbers from 30,000 to 70,000. Heat transfer coefficients were measured using the thermocouples-copper-plate-heater regional average method. Heat transfer results are obtained over a wide range of Reynolds numbers and rotation numbers. An increase in heat transfer rates due to rotation is observed in radially outward passes; a reduction in heat transfer rate is observed in the radially inward pass. Regional heat transfer coefficients are correlated with Reynolds numbers for nonrotation and with rotation numbers for rotating condition, respectively. The results can be useful for understanding real rotor blade coolant passage heat transfer under low Mach number, medium–high Reynolds number, and high rotation number conditions.


Author(s):  
Alain J. Kassab ◽  
Eduardo A. Divo ◽  
Minking K. Chyu ◽  
Frank J. Cunha

The purpose of the inverse problem considered in this study is to resolve heat transfer coefficient distributions by solving a steady-state inverse problem. Temperature measurements at interior locations supply the additional information that renders the inverse problem solvable. A regularized quadratic functional is defined to measure the deviation of computed temperatures from the values under current estimates of the heat transfer coefficient distribution at the surface exposed to convective heat transfer. The inverse problem is solved by minimizing this functional using a parallelized genetic algorithm (PGA) as the minimization algorithm and a two-dimensional multi-region boundary element method (BEM) heat conduction code as the field variable solver. Results are presented for a regular rectangular geometry and an irregular geometry representative of a blade trailing edge and demonstrate the success of the approach in retrieving accurate heat transfer coefficient distributions.


2000 ◽  
Vol 123 (2) ◽  
pp. 404-407 ◽  
Author(s):  
C. Cui ◽  
X. Y. Huang ◽  
C. Y. Liu

An experimental study was conducted on the heat transfer characteristics of flow through a porous channel with discrete heat sources on the upper wall. The temperatures along the heated channel wall were measured with different heat fluxes and the local Nusselt numbers were calculated at the different Reynolds numbers. The temperature distribution of the fluid inside the channel was also measured at several points. The experimental results were compared with that predicted by an analytical model using the Green’s integral over the discrete sources, and a good agreement between the two was obtained. The experimental results confirmed that the heat transfer would be more significant at leading edges of the strip heaters and at higher Reynolds numbers.


2019 ◽  
Vol 142 (6) ◽  
Author(s):  
Mandana S. Saravani ◽  
Nicholas J. DiPasquale ◽  
Ahmad I. Abbas ◽  
Ryoichi S. Amano

Abstract This study presents findings on combined effects of Reynolds number and rotational effect for a two-pass channel with a 180-deg turn, numerically and experimentally. To have a better understanding of the flow behavior and to create a baseline for future studies, a smooth wall channel with the square cross section is used in this study. The Reynolds number varies between 6000 and 35,000. Furthermore, by changing the rotational speed, the maximum rotation number of 1.5 is achieved. For the numerical investigation, large eddy simulation (LES) is utilized. Results from the numerical study show a good agreement with the experimental data. From the results, it can be concluded that increasing both Reynolds number and rotational speed is in favor of the heat transfer coefficient enhancement, especially in the turn region.


Author(s):  
P. J. Magari ◽  
L. E. LaGraff

An experimental investigation of wake-induced unsteady heat transfer in the stagnation region of a cylinder was conducted. The objective of the study was to create a quasi-steady representation of the stator/rotor interaction in a gas turbine using two stationary cylinders in crossflow. In this simulation, a larger cylinder, representing the leading-edge region of a rotor blade, was immersed in the wake of a smaller cylinder, represenung the trailing-edge region of a stator vane. Time-averaged and time-resolved heat-transfer results were obtained over a wide range of Reynolds numbers at two Mach numbers: one incompressible and one transonic. The tests were conducted at Reynolds numbers, Mach numbers and gas-to-wall temperature ratios characteristic of turbine engine conditions in an isentropic compression-heated transient wind tunnel (LICH tube). The augmentation of the heat transfer in the stagnation region due to wake unsteadiness was documented by comparison with isolated cylinder tests. It was found that the time-averaged heat-transfer rate at the stagnation line, expressed in terms of the Frossling number (Nu/√Re), reached a maximum independent of the Reynolds number. The power spectra and cross correlation of the heat-transfer signals in the stagnation region revealed the importance of large vortical structures shed from the upstream wake generator. These structures caused large positive and negative excursions about the mean heat-transfer rate in the stagnation region.


Author(s):  
Florian Hoefler ◽  
Nils Dietrich ◽  
Jens von Wolfersdorf

A confined jet impingement configuration has been investigated in which the matter of interest is the convective heat transfer from the airflow to the passage walls. The geometry is similar to gas turbine applications. The setup is distinct from usual cooling passages by the fact that no crossflow and no bulk flow direction are present. The flow exhausts through two staggered rows of holes opposing the impingement wall. Hence, a complex 3-D vortex system arises, which entails a complex heat transfer situation. The transient Thermochromic Liquid Crystal (TLC) method was used to measure the heat transfer on the passage walls. Due to the nature of the experiment, the fluid as well as the wall temperature vary with location and time. As a prerequisite of the transient TLC technique, the heat transfer coefficient is assumed to be constant over the transient experiment. Therefore, additional measures were taken to qualify this assumption. The linear relation between heat flux and temperature difference could be verified for all measurement sites. This validates the assumption of a constant heat transfer coefficient which was made for the transient TLC experiments. Nusselt number evaluations from all techniques show a good agreement, considering the respective uncertainty ranges. For all sites the Nusselt numbers range within ±9% of the values gained from the TLC measurement.


Author(s):  
Yasir M. Shariff ◽  
T. S. Ravigururajan

Experimental results from single-phase refrigerant mixture flow in smooth and micro-coil enhanced meso-channels are presented. R-407C — a mixture of R-32 (23%)/R-125 (25%)/R-134a (52%) — is used as the working fluid and different micro-coils are used in conjunction with two meso-channels (2.78mm and 3.97 mm) to obtain distinct roughness parameters. The flow was varied over a range of Reynolds numbers and experiments were conducted over a heat flux range of 2 to 11 kW/m2. The heat transfer coefficient was found to be dependent on both the heat flux as well as mass flux levels. Results show that heat transfer characteristics are comparable to R-113, and that micro-coil inserts enhanced the heat transfer performance compared to the performance in smooth meso-channels.


Sign in / Sign up

Export Citation Format

Share Document