Measurement of Air Velocity Components of Natural Convective Interzonal Airflow

1987 ◽  
Vol 109 (4) ◽  
pp. 267-273 ◽  
Author(s):  
Bal M. Mahajan

Recent flow visualization tests performed at the National Bureau of Standards Passive Solar Test Facility indicated that the natural convective interzonal flow through a doorway is three-dimensional with the velocity components perpendicular to the plane of the opening and the plane of the floor appearing dominant. In order to further investigate the velocity components of the interzonal airflow through a doorway, an experimental study was undertaken. A simple one-dimensional model is modified to apply to two-dimensional airflow. Empirical expressions for the X velocity component and interzonal mass flow rate are developed. The measured velocity and mass flow rate data and the resulting empirical expression are compared with the values predicted by the simple one-dimensional model. It is found that the natural convective interzonal airflow may be adequately represented by two one-dimensional equations, one for the outflow and a different one for the inflow, provided that proper values of the outflow and inflow discharge coefficients are known.

Author(s):  
Chen Li ◽  
Jian-jun Liu

The turbine blade cooling design is a complex procedure including one-dimensional preliminary cooling design, detailed two-dimensional design and fluid network analyses, and three-dimensional conjugate heat transfer and FEM predictions. Frequent alteration and modification of the cooling configurations make it unpractical to obtain all of three-dimensional design results quickly. Preliminary cooling design deals mainly with the coolant requirements and can be knitted into fluid network to look up the expected cooling structural style to promote three-dimensional geometry design. Previous methods to estimate the coolant requirements of the whole turbine blade in the preliminary cooling design were usually based on the semi-empirical air-cooled blade data. This paper combines turbine blade internal and external cooling, and presents a one-dimensional theoretical analytical method to investigate blade cooling performance, assuming that the coolant temperature increases along the blade span. Firstly, a function of non-dimensional cooling mass flow rate is derived to describe the new relationship between adiabatic film cooling effectiveness and overall cooling effectiveness. Secondly, a new variable related to film cooling is found to estimate the required adiabatic film cooling effectiveness without using the empirical correlations. Finally, a theoretical calculation about the relationship between non-dimensional cooling mass flow rate and overall cooling effectiveness well corresponds to semi-empirical air-cooled blade data within regular range of cooling efficiency. The currently proposed method is also a useful tool for the blade thermal analysis and the sensitivity analysis of coolant requirements to various design parameters. It not only can provide all the possible options at the given gas and coolant inlet temperatures to meet the design requirement, but also can give the third boundary conditions for calculating the blade temperature field. It’s convenient to use the heat transfer characteristic of internal cooling structures to estimate the coolant mass flow rate and the channel hydraulic diameter for both convection cooling and film cooling.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Yoon Jo Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Young-Joon Lee ◽  
Sung-Kyu Lim

It is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching ∼300 W/cm2. In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.


1976 ◽  
Vol 18 (5) ◽  
pp. 234-238 ◽  
Author(s):  
D. H. McQueen

The one-dimensional equations of surge in centrifugal compressors are solved graphically for the pressure head and mass flow rate as functions of time for a variety of situations, and the results are discussed in terms of the acoustical properties of the external piping. Two important parameters affecting the nature of the surge limit cycle are found to be simply related to the acoustic capacitance and acoustic inductance of the system.


Author(s):  
Yang Chen ◽  
Jun Li ◽  
Chaoyang Tian ◽  
Gangyun Zhong ◽  
Xiaoping Fan ◽  
...  

The aerodynamic performance of three-stage turbine with different types of leakage flows was experimentally and numerically studied in this paper. The leakage flows of three-stage turbine included the shroud seal leakage flow between the rotor blade tip and case, the diaphragm seal leakage flow between the stator blade diaphragm and shaft, as well as the shaft packing leakage flow and the gap leakage flow between the rotor blade curved fir-tree root and wheel disk. The total aerodynamic performance of three-stage turbine including leakage flows was firstly experimentally measured. The detailed flow field and aerodynamic performance were also numerically investigated using three-dimensional Reynolds-Averaged Navier-Stokes (RANS) and S-A turbulence model. The numerical mass flow rate and efficiency showed well agreement with experimental data. The effects of leakage flows between the fir-tree root and the wheel disk were studied. All leakage mass flow fractions, including the mass flow rate in each hole for all sets of root gaps were given for comparison. The effect of leakage flow on the aerodynamic performance of three-stage was illustrated and discussed.


2018 ◽  
Vol 20 (6) ◽  
pp. 624-639 ◽  
Author(s):  
Kang Song ◽  
Ben Zhao ◽  
Harold Sun ◽  
Weilin Yi

Turbocharger compressor, when fitted to a vehicle, usually operates with a curved inlet pipe which leads to distorted inlet flow field, hence deteriorating compressor flow capability. During the measurement of compressor performance, turbocharger-engine matching and controller design, the inlet flow field is, however, assumed to be uniform, which deviates from the real-world conditions. Consequently, the overall system performance could be compromised if the inlet distortion effect is ignored. To address this issue, in this article, a turbomachinery physics-based zero-dimensional model was proposed for the mass flow rate of a compressor with distorted inlet flow field due to 90° and 180° bent inlet pipe. The non-uniform flow is approximated as two-zone flow field, similar to parallel compressors, with the total pressure deviation between two zones modeled as a function of the flow velocity and pipe geometry. For each flow zone, the corresponding mass flow rate is estimated by approximating each sub-compressor as an adiabatic nozzle, where the fluid is driven by external work delivered by a compressor wheel governed by Euler’s turbomachinery equation. By including turbomachinery physics and compressor geometry information into the modeling, the model achieves high fidelity in compressor map interpretation and extrapolation, which is validated in experiments and the three-dimensional computational fluid dynamic simulation.


Author(s):  
Nathan Schroeder ◽  
Henk Laubscher ◽  
Brantley Mills ◽  
Clifford K. Ho

Abstract Falling particle receivers (FPRs) are being studied in concentrating solar power applications to enable high temperatures for supercritical CO2 (sCO2) Brayton power cycles. The falling particles are introduced into the cavity receiver via a linear actuated slide gate and irradiated by concentrated sunlight. The thickness of the particle curtain associated with the slide-gate opening dimension dictates the mass flow rate of the particle curtain. A thicker, higher mass flow rate, particle curtain would typically be associated with a smaller temperature rise through the receiver, and a thinner, lower mass flow rate, particle curtain would result in a larger temperature rise. Using the receiver outlet temperature as the process variable and the linear actuated slide gate as the input parameter a proportional, integral, and derivative (PID) controller was implemented to control the temperature of the particles leaving the receiver. The PID parameters were tuned to respond in a quick and stable manner. The PID controlled slide gate was tested using the 1 MW receiver at the National Solar Thermal Test Facility (NSTTF). The receiver outlet temperature was ramped from ambient to 800°C then maintained at the setpoint temperature. After reaching a steady-state, perturbations of 15%–20% of the initial power were applied by removing heliostats to simulate passing clouds. The PID controller reacted to the change in the input power by adjusting the mass flow rate through the receiver to maintain a constant receiver outlet temperature. A goal of ±2σ ≤ 10°C in the outlet temperature for the 5 minutes following the perturbation was achieved.


Author(s):  
Mengying Shu ◽  
Mingyang Yang ◽  
Ricardo F. Martinez-Botas ◽  
Kangyao Deng ◽  
Lei Shi

The flow in intake manifold of a heavily downsized internal combustion engine has increased levels of unsteadiness due to the reduction of cylinder number and manifold arrangement. The turbocharger compressor is thus exposed to significant pulsating backpressure. This paper studies the response of a centrifugal compressor to this unsteadiness using an experimentally validated numerical method. A computational fluid dynamic (CFD) model with the volute and impeller is established and validated by experimental measurements. Following this, an unsteady three-dimensional (3D) simulation is conducted on a single passage imposed by the pulsating backpressure conditions, which are obtained by one-dimensional (1D) unsteady simulation. The performance of the rotor passage deviates from the steady performance and a hysteresis loop, which encapsulates the steady condition, is formed. Moreover, the unsteadiness of the impeller performance is enhanced as the mass flow rate reduces. The pulsating performance and flow structures near stall are more favorable than those seen at constant backpressure. The flow behavior at points with the same instantaneous mass flow rate is substantially different at different time locations on the pulse. The flow in the impeller is determined by not only the instantaneous boundary condition but also by the evolution history of flow field. This study provides insights in the influence of pulsating backpressure on compressor performance in actual engine situations, from which better turbo-engine matching might be benefited.


Author(s):  
K. V. L. Narayana Rao ◽  
N. Ravi Kumar ◽  
G. Ramesha ◽  
M. Devathathan

Can type combustors are robust, with ease of design, manufacturing and testing. They are extensively used in industrial gas turbines and aero engines. This paper is mainly based on the work carried out in designing and testing a can type combustion chamber which is operated using JET-A1 fuel. Based on the design requirements, the combustor is designed, fabricated and tested. The experimental results are analysed and compared with the design requirements. The basic dimensions of the combustor, like casing diameter, liner diameter, liner length and liner hole distribution are estimated through a proprietary developed code. An axial flow air swirler with 8 vanes and vane angle of 45 degree is designed to create a re-circulation zone for stabilizing the flame. The Monarch 4.0 GPH fuel nozzle with a cone angle of 80 degree is used. The igniter used is a high energy igniter with ignition energy of 2J and 60 sparks per minute. The combustor is modelled, meshed and analysed using the commercially available ansys-cfx code. The geometry of the combustor is modified iteratively based on the CFD results to meet the design requirements such as pressure loss and pattern factor. The combustor is fabricated using Ni-75 sheet of 1 mm thickness. A small combustor test facility is established. The combustor rig is tested for 50 Hours. The experimental results showed a blow-out phenomenon while the mass flow rate through the combustor is increased beyond a limit. Further through CFD analysis one of the cause for early blow out is identified to be a high mass flow rate through the swirler. The swirler area is partially blocked and many configurations are analysed. The optimum configuration is selected based on the flame position in the primary zone. The change in swirler area is implemented in the test model and further testing is carried out. The experimental results showed that the blow-out limit of the combustor is increased to a good extent. Hence the effect of swirler flow rate on recirculation zone length and flame blow out is also studied and presented. The experimental results showed that the pressure loss and pattern factor are in agreement with the design requirements.


Author(s):  
Michael J. Pekris ◽  
Gervas Franceschini ◽  
Andrew K. Owen ◽  
Terry V. Jones ◽  
David R. H. Gillespie

The secondary air system of a modern gas or steam turbine is configured to satisfy a number of requirements, such as to purge cavities and maintain a sufficient flow of cooling air to key engine components, for a minimum penalty on engine cycle efficiency and specific fuel consumption. Advanced sealing technologies, such as brush seals and leaf seals, are designed to maintain pressures in cavities adjacent to rotating shafts. They offer significant reductions in secondary air parasitic leakage flows over the legacy sealing technology, the labyrinth seal. The leaf seal comprises a series of stacked sheet elements which are inclined relative to the radial direction, offering increased axial rigidity, reduced radial stiffness, and good leakage performance. Investigations into leaf seal mechanical and flow performance have been conducted by previous researchers. However, limited understanding of the thermal behavior of contacting leaf seals under sustained shaft contact has led to the development of an analytical model in this study, which can be used to predict the power split between the leaf and rotor from predicted temperature rises during operation. This enables the effects of seal and rotor thermal growth and, therefore, implications on seal endurance and rotor mechanical integrity to be quantified. Consideration is given to the heat transfer coefficient in the leaf pack. A dimensional analysis of the leaf seal problem using the method of extended dimensions is presented, yielding the expected form of the relationship between seal frictional power generation, leakage mass flow rate, and rotor temperature rise. An analytical model is derived which is in agreement. Using the derived leaf temperature distribution formula, the theoretical leaf tip temperature rise and temperature distributions are computed over a range of mass flow rates and frictional heat values. Experimental data were collected in high-speed tests of a leaf seal prototype using the Engine Seal Test Facility at Oxford University. These data were used to populate the analytical model and collapsed well to confirm the expected linear relationship. In this form, the thermal characteristic can be used with predictions of mass flow rate and frictional power generated to estimate the leaf tip and rotor temperature rise in engine operation.


Sign in / Sign up

Export Citation Format

Share Document